Emergency battery installed 9 to 18 in series due to output voltage; therefore, it is difficult to check each battery status. TDP-BM-100, which is possible to check battery individually, is to find poor battery to show graph of battery status. In addition, it could be measured...
TDP-BM-100 5. Configuration and Operation Principle TDP-BM-100 consists as blow picture. MCU as a key component consists easily to check display data on touch panel as a graph type about battery status such as voltage of each voltage, total voltage of battery in series, and charging current.
TDP-BM-100 Battery Status Monitor [Photo2] Display 6. Displaying data and setting [Pic2] Display for battery 6-1. Displaying data ① Operating status: It displays current battery status. When batteries are charging, charging icon will be displayed. ② Individual voltage for battery: Displaying voltage of battery individually.
⑦ Firmware version: It shows current version of firmware. 6-2. Setting TDP-BM-100 is simple and convenience due to apply for touch screen type of display. You press saw-toothed wheel shape of icon to enter set-up mode. In the set-up mode, you could set battery capacity, battery voltage, quantity of battery, rated voltage of current sensor, standard of low battery alarm, overcharging alarm standard, and number of poor battery alarm.
Battery Status Monitor TDP-BM-100 8. Electrical wiring Detached LAN cable Connection terminal Warning Out Battery connection terminal block Hall CT 연결 단 자대 8-1 Common matters (one-piece type / separate type) POWER Battery Charger P B N COM NC(B) NO(A)