Page 1
OPERATION MANUAL Model : BTM-505N Dedicated to runing water lines Note : There is a protection film on the operation panel of this product. Read this manual carefully for proper use of the product. Keep the manual in a safe place and refer to the manual whenever necessary.
The performance of the unit will depend on the quality of water source. Please check water condition before the installation of this product. Biontech Co., Ltd. will not be held resposible. Please keep this manual and other documents for future reference.
Page 3
Components Components The following components need to be checked before installation. The illustration shows basic components, their shapes may appear different from the actual components. Adaptor(Optional) Water Supply Control Valve Set Flexible Alkaline Faucet Hose Band Safety Pins Wall-hanging Nails and Fuse 2 Nails 2 Anchor Bolts 2 Screws...
Front Side Rear Side Bottom Side Safety pin Source water outlet Water supply valve (One-touch) Source water inlet Water supply valve one-touch fitting [Inlet detailed picture] Number Name Function Front Plate Where the circuit systems and devices are fixed Operating Panel Operation and display of functions Flexible Alkaline Faucet Outlet pipe from which the alkaline ionized water flows out...
Page 5
Operating Panel Indication light for purified water To be turned on when purified water is chosen Indication light for flow volume. High indication light. Indicating when the flow volume is higher than the Indication light for appropriate level alkaline ionized water. Standard indication To be turned on when alkaline light...
Description of the symbol marks The following describes the precautionary items that can prevent the potential damage to the body or the property. The cases of misapplication and resultant risks are divided into Warning and Caution items. You are required to read thoroughly and comply with the descriptions considering they are related to your safety.
Page 7
WEEE Directive - Warning - Should be followed for your safety. This application can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Caution - Malfunction or accidents can be occured. Do not place any other objects on the product. Do not install the product in the areas described as the following. Installation Precautions Requiring you to check the rated voltage before Do not install the product in a place where the Precautions for connecting the acidic water connecting the electric cord.
Caution Check whether the components to be installed at the water tap are appropriate. Should use the standard hose (1/4"), supplied by the company for the connection. Use the one- touch adapter to fasten the hose before fixing the safety pin as illustrated in Page 3. - If the standard hose is not used, damage due to water pressure can be caused, possibly leading to water leakage Do not connect the product to a warm water pipe.
Page 10
2. Deck type sink mounted water tap [Drawing 1] The following fools ate necessary for installation work Pipe wrench or spanner Hole cutter Teflon tape Electric drill General Size: screwdriver Diameter1/4” [Drawing 2] [Drawing 4] Water valve of Cold water Place of hole drilled Steel Hose Groove...
Page 11
3. Water Supply Control Valve How to assemble the valve to the faucet Assembly method of valve for Deck-sink water tap Take the little screen out Tighten the screws with screw driver, after inserting the rubber seal Water flows into ionizer when the lever is turned to side Cold water inlet Nut Water flows down ward when the lever is turned to down Screw...
Page 12
Caution Do not install the product in the following areas: - If not followed, malfunctioning can be caused. If horizontality can not be acquired If vibration and impact can be felt If direct sunlight comes in If bathroom is installed or winds and rains can affect If there is a risk of breaking due to freezing If there are lots of moisture or dusts lf damage can be caused to the product...
Precautions for use Important safeguards Danger - To reduce the risk of electrocutions. Warning - To reduce the risk of burns, electrocution, fire, or injury to persons.
Caution Use tap water only. - This machine is manufactured for drinking water based on standard tap water. Do not use the following water, as problems may arise: Turbid and contaminated water Water with high hardness Very salty water Water with high concentration of red rust Precautions for using the product Do not hold up the main case while holding the outlet flexible pipe.
Page 15
Use the product appropriately for each purpose pH value instructed pH level selection Indicated When infusing vegetables to remove their bitter taste High 10.5 When washing soak vegetables to eliminating Agricultral chemical. Use it for drinking after consulting the doctor Recommendable for medical and culinary usage Recommendable for drinking and cooking Alkaline...
How to store and manage the product after it is used. Precautions for using it 1. How to store and manage the product after using it. Turn off the power before moving the product Do not let water come inside the main body. Do not block the outlet nozzle or the drainage hose arbitrarily.
Selecting alkaline ionized water Operation indication panel 1. Open the water supply control valve to let the water Alkaline pH flow in. indication button 2. Use the pH button to select a stage. - The value of selected pH stage is indicated. - In case of “Alkaline”, any value between stage 1~5 will be indicated.
Caution Acidic ionized water is not for drinking, so do not drink it. Use the water after letting the water flow through for about 5 seconds right after the generation is initiated. Use the water initially daily after letting the water flow through for 10 ~ 15 seconds by opening the water tap completely.
How to measure the pH value (Ion concentration) The pH values (Ion concentration) of the generated alkaline or acidic ionized water can be measured. Check the generated water after adjusting the water pressure to meet the standard water flow volume (1.5 /Min.) according to the ionized water generation method.
How to replace the filter Do not disconnect the electric plug. (When the plug is disconnected, the system can be restored when the reset button is pushed) (Picutre 3) (Picutre 1) (Picutre 2) (Picutre 6) (Picutre 4) (Picutre 5) 1.Open the cover and remove the filter. (Picutre1~3) Be careful of the possible water coming out of the filter.
Cleaning Filter Calcium scale in electrodes may cause…. The reason for the calcium scale on the alkaline side of the water ionizer is because the high pH of the water causes the minerals in the water to precipitate out of the water and become displaced.
1. How to use alkaline ionized water For the initial 7~14days When using it daily Children Adults Remarks Children Adults Remarks Alkaline ionized 2~3 cups a Stage 1 Stage 1 Stage 1~2 Stage 2~3 water Should follow the items for your safety. Caution Do not use the following type of water Acidic water.
Page 24
Various dishes When cooking bamboo shoots, tree shoots, taro and seaweed with the alkaline water, the biting taste and the souring taste will be gone while the natural taste will enriched. When using it as the water for cooking fish, the fishy smell will be eliminated, making the fish taste better. Liquors, cocktails The liquors will be made highly mild and soft.
When cleaning the chopping board When you use the chopping board continuously for a long time, it will be full of knife scars. Then filthy impurities can be stuck in those knife scars. Use the acidic ionized water to clean and sanitize the chopping board completely.
Page 26
Q (Questions) A (Answers) There should be no problems with using The red lamp is turned on at Strong Alkaline the water for soaking out the puckery or Stage 5 . Is it OK when we use the water for soaking out the puckery or bitter tastes of bitter tastes of vegetables or washing vegetables or washing them?
Q (Questions) A (Answers) What is the pH of the acidic water coming out Acidic water Selection stage Purpose pH value of the acidic water outlet in the middle of the Eliminate the Strong alkaline alkaline ionized water being used? pH4.0 fishy smell after pH10.0 0.5...
Page 28
Symptoms Causes and actions 1) ERROR MODE: Error indication by ERR 3 1) Indication for the overheating of electrolysis cell. (For overheating of electrolysis cell) 2) ERROR MODE: Error indication by ERR OF 2) Indication for water flow volume exceeding 3.3 /Min. (For excessive water flow volume) 3) ERROR MODE: Error indication by ERR 8 3) Indication for a fake filter...
Page 29
Symptoms Causes and actions The outflow water volume is low or there is no Is the life span of the filter overdue? outflow. (Need to check the filter usage status number) => Replace the filter. The life span of the filter can be shortened when it is blocked due to the sever pollution of the source Is the filter wrongly fixed? water.
Page 30
Symptoms Causes and actions Water keeps [dripping] from the outlets (Especially the The remaining water inside the outset can acidic water outlet) even after the water supply control comes out valve is turned off. => Not malfunctioning. The rinsing operation is in progress. =>...
Water Ionizer BTM-505N Class 2, Type B equipment 120V 220V 230V 240V / 50Hz 60Hz To tap water 320x340x140 (WxHxD) mm About 6.5 70~500 kgf/ 5 ~ 30 °C Built-in temp. sensors: 2 sensors (automatic restoration) Continuous electrolysis “ Including alkaline and Standard 1.5 /min...
Page 32
Indemnification Type of consumer damage Within warranty After warranty If repair is necessary within a month after Charged Replacement purchase due to manufacturing defect. service Charged If a replaced product requires major repair Replacement service within a month of replacement. Charged If defect occurs.
Page 33
F. Customer s failure to present the product warranty. Date of Purchase : (Day) (Month) (Year) Model BTM-505N Product Mfg. No. C u s t o m e r A d d r e s s S o l d b y...
Page 36
Bion-Tech Co., Ltd. 298-15 Gongdan-ro(Geumjeong-dong), Gunpo-si, Gyeonggi-do Korea Tel : 82-31-459-3853 Fax : 82-31-429-3859 E-mail : btm@biontech.biz http://www.bion-tech.com (Korean) http://www.biontech.biz (International) These instruction shall also be available in an alternative format, e.g. in a soft copy on the website.
Need help?
Do you have a question about the BTM-505N and is the answer not in the manual?
Questions and answers