Black cord lead connects to the outside terminal of the circuit breaker switch.
-
Green cord wire connects to the motor ground.
Figure 2. Cord and circuit breaker switch.
PC Board
(see figure 3)
-
The motor field lead closest to the PC board connects to terminal M1. There should be no
current reading.
-
The motor field lead closest to the RFI board connects to terminal M2. There should be line
current when cycle start is activated.
-
One white lead from the cord connects to terminal N. There should be no current reading.
-
The black lead from the center terminal of the circuit breaker switch connects to terminal L.
There should be line current present.
-
The 4-conductor cable from the LED cycle counter connects to terminal J7.
-
The 3-conductor cable from the speed control connects to terminal J8.
-
The 2 – 3-conductor cables from the jar sensors connect to terminals IC3 and IC4
-
The lead from terminal P1 on the RFI board connects to the P1 terminal on the PC board.
-
The lead from terminal P2 on the RFI board connects to the P2 terminal on the PC board.
Note: When making the following connections "top" and "bottom" are relative to the machine assembled
and sitting upright.
-
"Off " terminal lead connects to the top terminal of the on/off switch.
-5 VDC reading with switch in off position.
-
"On" terminal lead connects to the center terminal of the on/off switch.
-5 VDC reading while the machine is running.
-
"Start" terminal lead connects to bottom terminal of the on/off switch.
Momentary -5 VDC when start switch is activated.
-
"Pulse" terminal lead connects to the top terminal of the hi/low/pulse switch.
Revision Description:
Request Number:
4421 Waterfront Drive
Glen Allen, VA 23060
Issue Code(s):
ENG-FRM-RIC-4.32, Rev. E
Technical Data Sheet
Production Release
DOC2649
Revision Date:
2
CS, SP
Page:
4/17/12
4
Document #:
of
Approved by:
DOC2649
520006200
Rev:
A

Advertisement

loading