Download Print this page

LOCKEY USA TB200 Installation Instructions

Hydraulic gate closer

Advertisement

Quick Links

- This gate closer is mounted on the swing/open side of the gate and pushes the gate closed.
- A Gate Stop must be installed to keep gate from opening beyond 90 degrees.
- If using tension/spring hinges, release all tension and remove spring closers.
- Do NOT use with bulldog/strap style hinges. For best results, use male/female style hinges.
No.
Part Name
1
Hydraulic Cylinder
2
Post Bracket (Triangular)
3
Gate Bracket
4
Fitting Bar
5
Securing Pins (Hexagon Head)
6
Spacers
7
Cap Screws
8
Washers
9
Retaining Bar
KEY:
= Hinge Pin
= MUST measure 2-4"
Step 1: Secure Post Bracket (#2) to Gate Post *This step is the MOST important. The Post Bracket (#2) MUST be mounted first.*
Hold Post Bracket (#2) to the face of the gate post.
Measure from the center of the first hole on Post Bracket (#2A) to the center of the Hinge Pin .
This measurement MUST be between 2" and 4".
Clamp bracket into place.
Note: Regardless of hinge arrangement, the measurement from the center of the Hinge Pin to the center of hole 2A on Post Bracket (#2)
must not exceed 4" or damage to the gate closer may occur.
= MUST measure 2-4"
Gate
Gate
Post
Post
Step 2: Measure/Secure Gate Bracket (#3)
With gate in closed position, attach Fitting Bar (#4) to Post Bracket (#2) using a Securing Pin (#5) in hole 2-D (shown below (left)).
Next, place a Securing Pin (#5) in the opposite end of the Fitting Bar (#4) and secure to the Gate Bracket (#3).
Hold Gate Bracket (#3) to the gate and clamp into place.
The distance from the center of hole 2-D and the center of the Gate Bracket must measure 29 3/8".
Clamp/secure brackets then remove Fitting Bar (#4).
Note: If wall mounting, use Gate Bracket (#3) on the wall and the Post Bracket (#2) on the gate (shown below (right)).
Gate in CLOSED position
Gate
Post
2A
2B
2C
2D
Qty.
1
<--- Gate End
1
1
1
2
4
2
2
1

INSTALLATION INSTRUCTIONS:

Gate
Post
Gate
= 29 3/8"
Hydraulic Gate Closer
TB200, TB400, TB600
Installation Instructions
Important:
Post End --->
Gate
Post
Gate in CLOSED position
Gate Closer
36" Gate
Added Opening Force
No Closer
3/4 lb.
TB200
6 lbs.
TB400
10 lbs.
TB600
13 lbs.
Added Force at 45 degrees Open
TB200
7 lbs.
TB400
13 lbs.
TB600
18.5 lbs.
Constant
Closing
Approximate
Pressure
Width
0 lbs.
45 lbs.
36-52 Inches
90 lbs.
40-64 Inches
135 lbs.
44-72 Inches
Chainlink
Post
Gate
= 29 3/8"
Wall Mounting a TB Gate Closer
(may restrict 90 degree opening)
48" Gate 60" Gate
1/2 lb.
1/4 lb.
4 lbs.
3 lbs.
8 lbs.
6 lbs.
10 lbs.
8 lbs.
5 lbs.
4.5 lbs.
9.5 lbs.
8 lbs.
13.5 lbs.
12 lbs.
Approximate
Weight
50-125 lbs.
75-175 lbs.
150-250 lbs.
Chainlink
Post
2A
2B
2C
2D

Advertisement

loading

Summary of Contents for LOCKEY USA TB200

  • Page 1: Installation Instructions

    Hydraulic Gate Closer TB200, TB400, TB600 Installation Instructions Important: - This gate closer is mounted on the swing/open side of the gate and pushes the gate closed. - A Gate Stop must be installed to keep gate from opening beyond 90 degrees.
  • Page 2 INSTALLATION INSTRUCTIONS CONTINUED: Step 3: Verify Measurements in OPEN Position Open gate 90 degrees from closed position. Measure the distance from the center of hole 2D on the Post Bracket (#2) to the center of the Gate Bracket (#3). The distance MUST measure 22” or MORE. If the distance is less than 22”, start back at Step 1. Once you have verified all measurements, close the gate and secure all mounting brackets.

This manual is also suitable for:

Tb400Tb600