Table of Contents
loading

Summary of Contents for Oriel IQE-LIGHT-BIAS

  • Page 1 IQ -LIG BIAS QE Li ght B Bias sing Syst User's s Man nual amily of Brands – – Corion • New F Focus™ • Oriel nstruments • Richa ardson Gratings™ • Spectra-Physic ® ® ® MIQE-LIGHT-B BIAS ev: 08/2015...
  • Page 2: Table Of Contents

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 2 TABLE OF CONTENTS INTRODUCTION ..........................3   INSTALLATION ............................ 4   THE FIBER BUNDLE ........................... 7   COLORED GLASS FILTERS ....................... 8   PRODUCTS FOR CARE AND MAINTENANCE .................. 9   REPLACEMENT PARTS ........................10  ...
  • Page 3: Introduction

    The kit includes an external quartz tungsten halogen light source, mounting flange, bifurcated fiber optic cable and filter holder. A wide selection of filters are available from Oriel to meet a variety of testing needs. These filters are purchased separately.
  • Page 4: Installation

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 4 2 INSTALLATION Read all included documentation to understand the handling and care required for each of the system’s components prior to beginning the installation. 1. Place the fiber light source in a convenient location where the power cord can reach the electrical mains and the interface cord can reach the IQE system.
  • Page 5: Figure 2: Glass Filter Installation

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 5 6. Install the optional colored filters into the filter slide as shown in Figure 2 using the filter wrench provided, or a spanner wrench, to tighten the retaining rings. Do not over tighten, as this will damage the filters.
  • Page 6: Figure 3: Filter Holder Assembly

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 6 11. Ensure that the beam probes are not aimed at the eyes of any person. Then turn on the fiber light source and move the fiber holders on the mounting adapter until the desired light output onto the sample is achieved.
  • Page 7: The Fiber Bundle

    The bifurcated glass fiber bundle included with the Light Bias Kit is comb randomized to produce evenly divided outputs. When light is uniformly focused onto the common end, each leg can transmit 43% of the total incident energy. The common end and the two legs are all terminated with standard Oriel 11 mm ferrules.
  • Page 8: Colored Glass Filters

    Page 8 4 COLORED GLASS FILTERS Oriel colored glass filters serve as broadband, band pass, or long-wave pass filters. A variety of Schott color glasses covering the visible and near-infrared wavelength regions are offered. These filters are precision polished for demanding research or OEM applications.
  • Page 9: Products For Care And Maintenance

    5 PRODUCTS FOR CARE AND MAINTENANCE As part of the Newport family of brands, Oriel Instruments is able to offer a variety of items needed for the care and maintenance of optics. The appropriate cleaning method varies according to the material and application for which it is being used.
  • Page 10: Replacement Parts

    Additionally, the following replacement parts may also be purchased at any time from Oriel Instruments. For pricing and lead times, United States and Canadian customers should contact the Oriel Service Department. All other customer must contact their regional sales representative.
  • Page 11: Fiber Illuminator Setup

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 11 7 FIBER ILLUMINATOR SETUP VOLTAGE SELECTION The 66088 illuminator has universal AC voltage input. Connect the appropriate AC line cord to the DC950 and connect to an AC power receptacle. The 66088 can operate with line voltages from 100 to 250 VAC and at 50 Hz.
  • Page 12: Fiber Illuminator Operation

    IQE-LIGH T-BIAS ® ORIEL FIBER R OPTIC ILLUMIN NATOR Page 12 8 FIBE ER ILLUM MINATOR R OPERA TION Insert the e power cord into the pow wer entry mod dule at the re ear of the illum minator. Nex...
  • Page 13: Remote Intensity Control

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 13 REMOTE INTENSITY CONTROL The Remote Intensity Control is located on Pin 3 of the Remote Interface. When the LOCAL/REMOTE switch is in the REMOTE position the intensity is controlled by the signal applied to Pin 3. NOTE: The front panel intensity control is deactivated in remote mode.
  • Page 14: Lamp Fail Signal

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 14 LAMP FAIL SIGNAL: A signal indicating that the lamp has failed is available on Pin 9. This signal is open collector (see Fig D). The user must supply the necessary circuitry to connect the lamp out signal to a signaling device. The maximum current through the circuit is 10 mA.
  • Page 15: Fiber Illuminator Lamp Module Replacement

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 15 9 FIBER ILLUMINATOR LAMP MODULE REPLACEMENT 1. Turn the illuminator intensity control fully counterclockwise (the 0 position) and run the illuminator with the fan for several minutes. Wait until the nosepiece is cool to the touch. Press the ON(1)/OFF(0) rocker switch to the OFF(0) position.
  • Page 16: Fiber Illuminator Lamp Replacement

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 16 10 FIBER ILLUMINATOR LAMP REPLACEMENT 1. Follow steps 1-4 of Lamp Module Replacement. 2. Check the lamp assembly to verify that the lamp and socket are cool before proceeding. 3. Lift and remove the lamp from the lamp holder by grasping the rear of the lamp adjacent to the lamp socket.
  • Page 17: Fiber Illuminator Fuse Replacement

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 17 11 FIBER ILLUMINATOR FUSE REPLACEMENT Press the ON(1)/OFF(0) switch to the OFF(0) position. Remove the AC line cord from the AC power receptacle. Remove the AC line cord from the power entry module at the rear of the illuminator. The fuse drawer is part of the power entry module.
  • Page 18: Fiber Illuminator Specifications

    IQE-LIGHT-BIAS ® ORIEL FIBER OPTIC ILLUMINATOR Page 18 12 FIBER ILLUMINATOR SPECIFICATIONS F/1.1 Lamp Voltage 21 VAC, nominal; adjustable from 0 - 21 VAC Lamp Input Power 150 W, nominal Lamp Life 200 – 10,000 hours depending on intensity level Color Temperature 3200°...
  • Page 19: Declaration Of Conformity

    Bruno Ret ty Authorized d to compile te echnical omenic Assalo documenta ation e Manager, O Oriel Products s Division Group Dire ector, PPT In nstrument and d Motion Euro 0 Long Beach h Boulevard Micro-Con ntrole Division...
  • Page 20: Warranty And Service

    Page 20 14 WARRANTY AND SERVICE CONTACTING ORIEL INSTRUMENTS Oriel Instruments belongs to Newport Corporation's family of brands. Thanks to a steadfast commitment to quality, innovation, hard work and customer care, Newport is trusted the world over as the complete source for all photonics and laser technology and equipment.
  • Page 21 Oriel's discretion. Oriel is not responsible for damage occurring in transit. The Owner of the product bears all risk of loss or damage to the returned Products until delivery at Oriel's facility. Oriel is not responsible for product damage once it has left the facility after repair or replacement has been completed.
  • Page 22 Except as otherwise expressly stated in Oriel's quote or in the current operating manual or other written guarantee for any of the Products, Oriel warrants that, for the period of time set forth below with respect to each Product or component type (the "Warranty Period"), the Products sold hereunder will be free from defects in material and workmanship, and will conform to the applicable specifications, under normal use and service when correctly installed and maintained.
  • Page 23 ORIEL FIBER OPTIC ILLUMINATOR Page 23 terms of this warranty shall not be binding on Oriel unless reduced to writing and approved by an expressly an authorized officer of Newport. LOANER / DEMO MATERIAL Persons receiving goods for demonstrations or temporary use or in any manner in which title is not transferred from Newport shall assume full responsibility for any and all damage while in their care, custody and control.
  • Page 24 No part of this manual may be reproduced or copied without the prior written approval of Newport Corporation. This manual has been provided for information only and product specifications are subject to change without notice. Any change will be reflected in future printings. Newport Corporation 1791 Deere Avenue Irvine, CA, 92606 USA Part No. IQE-LIGHT-BIAS...