Summary of Contents for Murata SN2100

  • Page 1 SN2100 Bluetooth Class 1 Module User Manual And Datasheet Version: 1.1 June 25, 2013 Note: SyChip, L.L.C. reserves the right to make changes in specifications at any time and without notice. The information furnished in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by SyChip for its use, nor any infringements of patents or other rights of third parties resulting from its use.
  • Page 2: Revision History

    Added packaging, labeling and regulatory information 0.63 May-22-2012 Viet H. Update the spec table Aug-10-2012 Y Fang Added Software and Development Tool sections Jun-25-2013 Y Fang Added Recommended host (customer) circuit board PCB pattern SyChip/Murata Confidential Page 2 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 3: Table Of Contents

        ROHS DECLARATION ............................26     REGULATORY INFORMATION ........................26     13.1 FCC N (USA) ............................26 OTICE     13.2 FCC L ........................27 ABELING EQUIREMENTS SyChip/Murata Confidential Page 3 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 4   13.6 CE N ) ............................28 OTICE UROPE     13.7 CE L ........................28 ABELING EQUIREMENTS     TECHNICAL SUPPORT CONTACT ......................... 29     DISCLAIMER ................................. 29 SyChip/Murata Confidential Page 4 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 5: List Of Figures

      ........................22 ABLE LUETOOTH TACK VAILABILITY   ............................23 ABLE EVELOPMENT OOLS   10 R ......................24 ABLE EFLOW ROFILE ECOMMENDATION   11 O ..........................26 ABLE RDERING NFORMATION SyChip/Murata Confidential Page 5 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 6: System Descriptions

    LGA form factor and can be simply dropped into the OEM’s design. The SN2100 offers total 110 dB link budget, which is significantly better than most of the Bluetooth® modules do in the market. This makes it a good fit for industrial control application that usually requires longer distance coverage.
  • Page 7: Block Diagram

    1.3 Block Diagram Figure 1 SN2100 Module Block Diagram SyChip/Murata Confidential Page 7 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 8: Mechanical Specifications

    Unit Dimension (LxWxH) 17.5 x 16.0 x 2.0 Dimension tolerances (LxWxH) +/- 0.2 mm 2.2 Module top and side view UNIT : mm Figure 2 Module Top and Side View SyChip/Murata Confidential Page 8 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 9: Module Bottom View

    2.3 Module bottom view Figure 3 Module Bottom View SyChip/Murata Confidential Page 9 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 10: Detailed Mechanical Data (Top View)

    2.4 Detailed mechanical data (top view) Figure 4 Detailed Mechanical Data (top view) SyChip/Murata Confidential Page 10 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 11: Module Pin-Out

    PCM Data Input AUD_OUT PCM Data Output AUD_CLK PCM Clock AUD_SYNC PCM Frame Sync Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Reserved Internal use only Ground Ground SyChip/Murata Confidential Page 11 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 12 Pin # Pin name Description Ground Ground Ground Ground SyChip/Murata Confidential Page 12 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 13: Dc Electrical Specifications

    At 2/4/8 mA 0.8 x VDD High Level Output Voltage At 0.1 mA VDD – 0.2 At 2/4/8 mA 0.2 x VDD Low Level output Voltage At 0.1 mA VDD : 1.8V SyChip/Murata Confidential Page 13 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 14: Rf Specifications

    Out of Band Spurious Emissions 30 – 1000 MHz (Operation Mode) <-36 1000 – 12750 MHz (Operation Mode) <-30 1800 – 1900 MHz (Operation Mode) <-47 5150 – 5300 MHz (Operation Mode) <-47 SyChip/Murata Confidential Page 14 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 15 (1) EIRP. SyChip/Murata Confidential Page 15 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 16: Rf Characteristics (Rx)

    Blocking Performance (BER <= 0.1%) 30MHz – 2000MHz -10< 2000MHz – 2400MHz -27< 2500MHz – 3000MHz -27< 3000MHz – 12750MHz -10< Intermodulation Performance -39< (BER <= 0.1%, -64 dBm input) Maximum Input Level -20< SyChip/Murata Confidential Page 16 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 17: Environmental Specifications

    Storage temperature Power supply -0.3 Moisture Sensitivity Level RoHS Restriction of Hazardous Substances Compliant 5.2 Operation conditions Table 7 Recommended Operating Conditions Symbol Parameter Units Power supply °C Operating temperature SyChip/Murata Confidential Page 17 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 18: Application Information

    The SN3020 module has an onboard antenna therefore it requires some special host PCB layout underneath the module such that the radio can achieve its best RF performance. Refer to Figure 6 for the requirements. SyChip/Murata Confidential Page 18 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 19: Module Location

    6.3 Module Location For optimum EIRP, customer is advised to use the recommended module location on their respective PCB. 6.3.1 Location in x-y plane SyChip/Murata Confidential Page 19 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 20: Figure 7 Recommended Locations In Xy-Plane

    Antenna Connector No GND in this area (See Fig.8) Antenna Shield Case Figure 7 Recommended Locations in xy-plane Figure 8 Locations Not Recommended in xy-plane SyChip/Murata Confidential Page 20 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 21: Location In Z-Plane

    6.3.2 Location in z-plane Metal Module Antenna Connector Antenna Mother Board Metal Figure 9 Recommended Locations in z-plane Metal Metal Metal Figure 10 Locations Not Recommended in xy-plane SyChip/Murata Confidential Page 21 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 22: Software

    7 Software 7.1 Software Architecture SN2100 module communicates with host processor via HCI interface. The HCI interface transports commands, events, ACL, and synchronous data between the device and the host using HCI data packets. The Bluetooth profile stack beyond HCI layer is required to be supported from host processor.
  • Page 23: Development Tools

    8 Development Tools SN2100 EM Development Kit is offered for customer application development on Texas Instruments MSP430 and Stellaris® platform. The table below lists the related tools that the customer may need. Table 9 Development Tools Tool Description Online Resources...
  • Page 24: Assembly Information

    Maximum time maintained above 217 120 seconds Peak temperature Maximum time within 5 C of peak temperature 20 seconds Ramp down rate C/second max Reflow Profile Time, seconds Figure 11 Reflow Profile Pattern SyChip/Murata Confidential Page 24 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 25: Packaging And Marking Information

    The 2D barcode is used for internal purposes. A pin 1 ID is stamped into the shield. Figure 13 Module Marking Detail SyChip/Murata Confidential Page 25 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 26: Ordering Information

    SyChip, L.L.C may void the user’s authority to operate the equipment. While an application of the SN2100 module in a product is not required to obtain a new FCC authorization for the module, this does not preclude the possibility that some other form of authorization or testing may be required for that end product.
  • Page 27: Fcc Labeling Requirements

    13.2 FCC Labeling Requirements When integrating the SN2100 into a product, the FCC labeling requirements must be met by the OEM. This includes placing a clearly visible label on the outside of the finished product specifying the SN2100 FCC identifier (FCC ID:QPU2100) as well as the underlined FCC Notice above.
  • Page 28: Ic Labeling Requirements

    “Contains”, or similar wording expressing the same meaning, as follows: Contains transmitter module IC:4523A-SN2100, where 4523A-SN2100 is the module’s certification number. 13.6 CE Notice (Europe) This device has been tested and certified for use in the European Union.
  • Page 29: Technical Support Contact

    Plano, TX 75093 Tel: (972) 202-8900 Fax: (972) 633-0327 Note: SyChip, LLC is an operating unit within Murata Wireless Solutions 15 Disclaimer Please read this notice before using the SN2100 product. Please note that the only warranty that SyChip LLC (“SyChip”) provides regarding the products is its conformance to the specifications provided herein.
  • Page 30: Sychip/Murata Confidential

    SyChip and that are determined by SyChip not to conform to such warranty. If SyChip elects to repair or replace such products, SyChip shall have reasonable time to repair such products or provide SyChip/Murata Confidential Page 30 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 31 End of Life - Please note that we may discontinue the manufacture of products, due to reasons such as, but not limited to, end of supply of materials and/or components from our suppliers. SyChip/Murata Confidential Page 31 of 31 SN2100 Datasheet Ver. 1.1...
  • Page 32 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Murata 88-00150-85...

Table of Contents