pass & seymour rt12 Installation Instructions

Programmable countdown

Advertisement

Quick Links

http://waterheatertimer.org/Countdown-timer-horsepower-ratings.html#RT
Delay
Setting the initial time
1. Press the Menu/Raise button ONCE to see the current Delay setting.
The factory setting for the Delay is 5 minutes, the minimum setting.
2. To change the setting, press the
5:00
}
Select/Save (middle) button.
10:00
3. Press the Menu/Raise button. The time
15:00
minutes
increases 5 minutes each time you press
the Raise button, until the time reaches
in 5-minute
... to
55:00
1 hour (100 ). After 1 hour, the time
increments
increases 15 minutes each time you press
}
100
the button, until it reaches 12 hours
115
(1200), then it goes back to 5 minutes
130
(5:00). You can go backwards at any point
145
hours &
to reduce the time, using the
Lower
200
button.
minutes
215
4. When the desired time shows in the
in 15-minute
display, press the Select/Save button to
increments
... to
1200
save the setting and exit the programming
mode.
Sound
Setting the
1. Press the Menu/Raise button TWICE to see the current Sound setting.
2. To change the setting, press the Select/Save (middle) button.
3. Press the Menu/Raise button to turn ON the warning and keypress sounds.
Lower button to turn OFF the warning and keypress sounds.
Press the
4. When the desired setting shows in the display, press the Select/Save button
to save the setting and exit the programming mode.
Flash
Setting the
1. Press the Menu/Raise button THREE times to see the current Flash
setting. If a fan is connected to the switch, Flash should be Off.
2. To change the setting, press the Select/Save (middle) button.
3. Press the Menu/Raise button to turn ON the warning flash. Press the
Lower button to turn OFF the warning flash.
4. When the desired setting shows in the display, press the Select/Save button
to save the setting and exit the programming mode.
Call 800.223.4185 for Technical Support

TROUBLESHOOTING

To test the time switch:

The pilot light behind the ON/OFF button should be ON when the switch is OFF
and OFF should appear in the display. Press the ON/OFF button. The connected
light or fan comes ON. The display shows the amount of time that the switch will
remain ON.
The connected light or fan should turn OFF in the number of minutes indicated
by the display. You can turn it OFF sooner by pressing the ON/OFF button again.

Light or fan will not turn ON (pilot light is visible):

Press ON/OFF button. The connected light or fan should turn ON. If not:
• Press and hold the button a second longer.
• Check the light bulb and/or motor switch on the fan mechanism.
• Turn OFF power to the circuit then check wire connections.
Light or fan will not turn ON (no pilot light or display is visible):
• Shade the switch from external light to make sure that the pilot light and
display are not ON.
• Make certain that the circuit breaker is ON and functioning.
• Turn OFF power to the circuit then check wire connections.
• Call 800.223.4185 for technical support.
Light or fan will not turn OFF:
• Press the ON/OFF button. If the connected light or fan does not turn OFF,
press the button and hold it a second longer.
• Turn OFF power to the circuit then check wire connections.
www.passandseymour.com
Limited FIVE YEAR Warranty
Pass & Seymour/Legrand will remedy any defect in workmanship or material in Pass & Seymour/Legrand
products which may develop under proper and normal use within five years from the date of purchase by a
consumer:
(1) by repair or replacement, or, at Pass & Seymour/Legrand's option, (2) by return of an amount equal to the
consumer's purchase price. Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour/Legrand does
not include or cover cost of labor for removal or reinstallation of the product. ALL OTHER FURTHER ELEMENTS
OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES) FOR BREACH OF ANY AND ALL EXPRESSED OR
IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE ARE EXCLUDED HEREBY. (Some states do not allow disclaimer or exclusion or limitation of incidental
or consequential damages, so the above disclaimers and limitation or exclusion may not apply to you.) ANY
IMPLIED WARRANTIES INCLUDING WHERE REQUIRED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE SHALL BE LIMITED TO THE FIVE YEAR PERIOD SET FORTH ABOVE. (Some states do
not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.)
To ensure safety, all repairs to Pass & Seymour/Legrand products must be made by Pass & Seymour/Legrand or
under its specific direction. Procedure to obtain performance of any warranty obligation is as follows: (1) Contact
Pass & Seymour/Legrand, P.O. Box 4822, Syracuse, NY 13221 for instructions concerning return or repair;
2) return the product to Pass & Seymour/Legrand, postage paid, with your name and address and a written
description of the installation or use of the Pass & Seymour/Legrand product, and the observed defects or failure
to operate, or other claimed basis for dissatisfaction.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
P.O. Box 4822, Syracuse, NY 13221-4822
Technical Support: 800.223.4185 • www.passandseymour.com
340804 Rev. B 08105
Please read all instructions before installing
RT12
Time Switch
Programmable Countdown
Alpha-numeric LCD display
ON/OFF button with
pilot light

SPECIFICATIONS

Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120VAC, 60Hz
Load
Single Pole Circuit . . . . . . . . . . . . . . . . . . . . . . .0–600 Watt
Incandescent or fluorescent lamp or 1/6HP fan motor
Time Delay . . . . . . . . . . . . . . . . . . . . . . .5 minutes to 12 hours
Environment
Operating Temperature . . . . . . . .32° to 104°F (0° to 40°C)
Humidity . . . . . . . . . . . . . . . . . . . .95% RH, non-condensing
Tools Needed:
Insulated Screwdriver
Wire Strippers

Advertisement

loading

Summary of Contents for pass & seymour rt12

  • Page 1 Please read all instructions before installing Delay TROUBLESHOOTING Setting the initial time RT12 1. Press the Menu/Raise button ONCE to see the current Delay setting. Time Switch The factory setting for the Delay is 5 minutes, the minimum setting. To test the time switch:...
  • Page 2 INSTALLATION & WIRING PROGRAMMING 4. Wire the time switch. The RT12 is a time switch that turns OFF the connected light or fan (load) when To program the time switch, you must access the programming buttons that are WARNING Twist the existing the selected time expires.
  • Page 3 • Final folded size: 4" (Wide) x 6" (High). Drawn by SOWINSKI Pass & Seymour Rev. Date 31 Aug 07 SYRACUSE, NY 12325 AGI Job No. Title: 340804 Part No. RT12 Installation Instructions Proofed By Drawing #: Rev. #: Orig. Drawing Date: Scale: 1:1 06249 22 FEB 06...