2601-06B
6-Gang
Charger Bracket
(for 2600-01 Chargers)
WARNING
Use only if package is received unopened and package and contents
are undamaged. If damage is noted, contact the shipper for replacement or
repair.
Prior to using any MAXAIR System or component, be sure to be familiar with
the systems' NIOSH approved configuration, and read and understand the
User Instructions.
Failure to follow the User Instructions may be hazardous to the user's
health.
The institution using this product in any application is responsible for deter-
mining the appropriateness of this equipment relative to regulatory require-
ments. Bio-Medical Devices Intl, Inc does not recommend the appropriate
systems for a particular institution or facility.
DO NOT use if any component is damaged. If any components are damaged
or contaminated and therefore unfit for safe and effective use, they should
be replaced immediately.
Use only MAXAIR Systems/ NIOSH approved compatible components.
This product contains dangerous voltages. DO NOT attempt to open the
product cover. This product contains no serviceable parts. DO NOT attempt
to modify any component.
If you need more information, contact your BMDI sales representative or call
BMDI customer service at 1-800-443-3842.
CAUTIONS
The chargers are only to be used with MAXAIR Systems Lithium-Ion batteries.
The chargers have internal fuses which blow if a fault occurs in the charger. In
addition, they are equipped with a fuse switch, which cuts off the unit in the case
of reverse polarity connection to the battery.
Do not leave any battery connected to a powered-on charger for longer than one
month. Refer to MAXAIR Systems User Instructions Manual (UIM) for further
details regarding intermittent use and storage of batteries.
The chargers have a plastic casing - avoid charger contact with oils, grease, etc.
as most plastics can be broken down by chemicals and solvents.
SYMBOLS DEFINITION
Read these instructions before using the charger.
This product is designed for indoor use only and should not come into con-
tact with water or dust. To prevent overheating the product should not be
covered during use.
The mains socket should be easily accessible. In the event of operational
error, the plug should be immediately removed from the socket.
The charger is double-insulated (Class II).
The product label "EN60601-1" indicates it complies with the requirements
of electromedical equipment and can be used in hospital environments. The
product should not be used in the vicinity of flammable anesthesia gases.
UL Recognized Component Marks for Canada and the United States.
Intended Use
2601-06
The MAXAIR Systems 6-Gang UL/CE Charger (2601-06) and
6-Gang
Charger Bracket (2601-06B) are intended for use only when charging
MAXAIR Systems' Lithium-Ion Batteries.
Charger
The 6-Gang Charger includes six 2600-01 UL/CE Chargers and is
(UL/CE)
capable of charging up to six MAXAIR Systems' Lithium-Ion batteries
simultaneously.
The Charger Bracket requires from one to six MAXAIR 2600-01
Chargers to be assembled (instructions below) with it to allow charging
NOTE:
of from one to six MAXAIR Lithium-Ion batteries.
1 connected
battery
Description
(NOT INCLUDED)
The 6-Gang Charger is fully assembled and ready to charge one to six
shown in photo.
MAXAIR Lithium-Ion batteries by plugging it into a properly grounded
110 VAC mains line.
The 6-Gang Charger kit requires the addition of one to six MAXAIR
2600-01 Chargers, and then is similar to the 6-Gang Charger.
ORDER NO:2600-01 ELECTRICAL OUTPUT
PART NO: 01432089 VOLTAGE: UP TO 16.8V
CHARGING INSTRUCTIONS
1. Connect the charger (single and/or 6-Gang) to an appropriate grounded
outlet power source (100-240 VAC, 50-60 Hz ) before connecting battery(ies).
The Charger green status LED should turn on.
2. Connect the battery(ies) to the charger(s). The Charger status LED should
change from green to red to indicate the battery is charging.
3. When charging is complete, the Charger LED should change to green.
Disconnect battery from charger. The battery is ready for use.
LED's INDICATE FOLLOWING CHARGE STATUS
Fast charge—LED indicator is red
The charger is in constant current mode.
Charge current is maximum.
Final charge—LED indicator is red
The charger is in constant voltage mode.
Charge current is less than maximum.
The battery is normally 80-95% charged.
The charger stays in this mode until the charge
current decreases to charge termination level.
Charge completed—LED indicator is green
Charging has stopped.
Charge current is zero.
LED indicator changes to green.
GENERAL SPECIFICATIONS
ELECTRICAL INPUT
VOLTAGE: 100-240 VAC,
50-60Hz max
CURRENT: UP TO 0.9A
CURRENT: 0.3A
P/N 01423158 REV A