Download Print this page

Permaconn DAS Reliance 128 Programming Manual

Alarm panel

Advertisement

Quick Links

DAS Reliance 128 Alarm Panel
 Keyswitch wiring
 Keyswitch programming
Background: There are three (3) Outputs available.
Outputs are 'Open Collector' @50mA switching negative - for heavier loads a relay must be used.
Outputs can be used for e.g. Keyswitch, opening gates or doors etc.
Ensure there is a common negative between Permaconn and the device being switched.
The outputs can be Opened, Closed or Pulsed remotely using the Permaconn Atlas web portal.
The Pocket Secure App can only 'Pulse' the Outputs. A Pulse is approx 1sec.
Compatible with 'Pocket Secure' remote arming App, available on iTunes, Google Play and the Windows Phone Store.
These outputs when wired to a Keyswitch zone on the Alarm Panel can arm & disarm up to a
maximum of three (3) areas when using 'Pocket Secure' app.
Each area should be independently controlled using a separate Keyswitch zone.
Arm/Disarm reporting MUST be Enabled. Pocket Secure App requires this for its status notifications.
Test each Output by placing the +ve leg of a multi meter on the +ve terminal that supplies power to the
Permaconn, then place the -ve leg of a multi meter on the Output terminal you wish to test. Pulse the
selected Output the result should go from 0v DC to 12v DC for approx 1sec and back to 0vDC.
DAS Reliance 128 Alarm Panel
If the Opening / Closing communicator codes are enabled, Key Switch arming/ disarming will report.
(Required for Pocket Secure App)
Feature 9: Segment 1: option 3: must be enabled: -
Feature 16: Segment 3: option 1 must be enabled: open / closed reporting.
Feature 68 segment 3 (
Key-switch zone (normally open switch) must be enabled.
E.g. 1: Using zones 1 – 8 (NOT zone doubling).
DAS Reliance 128 Keyswitch wiring & programming
OPENING / CLOSING COMMUNICATOR CODE.
Zones 1 - 8
Zones 1 - 6
RDC_3137_E_TA
DAS
DL150
Reliance 128
Com
Zone
-
Common -ve
+
3K3Ω resistor
2nd Band
nd
2
Digit
1st Band
3rd Band
st
1
Digit
mulitplier
Orange = 3
2
Orange = 3
Red = 10
3 3
00
Input a value of '30' Keyswitch zone type.
Zone
Feature 18
1
Segment 1
2
Segment 2
3
Segment 3
4
Segment 4
5
Segment 5
6
Segment 6
7
Segment 7
8
Segment 8
4th Band
Tolerance
= 3K3Ω
Page 1

Advertisement

loading

Summary of Contents for Permaconn DAS Reliance 128

  • Page 1 Test each Output by placing the +ve leg of a multi meter on the +ve terminal that supplies power to the Permaconn, then place the -ve leg of a multi meter on the Output terminal you wish to test. Pulse the selected Output the result should go from 0v DC to 12v DC for approx 1sec and back to 0vDC.
  • Page 2 Input a value of ‘30’ Keyswitch zone type. Zone Zone Feature 20 Segment 1 Common -ve Segment 2 Segment 3 Segment 4 Segment 5 Segment 6 Segment 7 Segment 8 Page 2 DAS Reliance 128 Keyswitch wiring & programming RDC_3137_E_TA...