  • Page 1 Conference Room Edition ® A speech protection system designed for conference rooms Installation and Operations Guide...
  • Page 2: Important Safety Instructions

    Qt Conference Room Edition Installation and Operations Guide page 3...
  • Page 3: Packing List

    50 ft two-conductor cables for privacy signs ▪ Hole saw ▪ Privacy sign ” x ” screws ▪ Wall plate adapter ” x ” screws ▪ Control module back panel ” x ” screws Qt Conference Room Edition Installation and Operations Guide page 4...
  • Page 4 Ceiling heights less than 10 ft. (2.4m) 8 ft. spacing (2.4m) Ceiling height is 10 up to 12 ft. (3m) 10 ft. spacing (3m) Ceiling heights 12 ft. and above (3.6m) 12 ft. spacing (3.6m) Qt Conference Room Edition Installation and Operations Guide page 8...
  • Page 5: Installation

    Emitters on each line are daisy-chained in series during installation. Each emitter has passive internal logic which rolls over its input channel to a different channel at its output port. Thus every fourth emitter is actually operated in parallel with the first. Qt Conference Room Edition Installation and Operations Guide page 12...
  • Page 6: Audio Input

    Normal operating level is reached. Control system programs should be written to anticipate and accommodate this behavior. Qt Conference Room Edition Installation and Operations Guide page 13...
  • Page 7 The “down” setting enables the external USB jack, used for firmware updates or for the optional Bluetooth dongle supplied with the Qt100 iPad app. Sign is USB connection active (special purpose see page 14) USB connection in use Qt Conference Room Edition Installation and Operations Guide page 14...
  • Page 8: Installing Qt Emitters

    (see Clearing Error Codes, page 31) Set the masking output level to the maximum level of 30. Connect the next OUTPUT cable to the emitter OUTPUT jack. Qt Conference Room Edition Installation and Operations Guide page 15...
  • Page 9 “whooshing” sound before installing the next emitter. Note: The input jack of each emitter bears this symbol and is located near the safety tie off The output jack of each emitter bears this symbol Qt Conference Room Edition Installation and Operations Guide page 16...
  • Page 10: Custom Cabling Guidelines

    Whenever feasible, don’t install the box on a wall requiring masking protection as it may exacerbate sound transmission problems The controller may be mounted in several ways: Qt Conference Room Edition Installation and Operations Guide page 17...
  • Page 11 ” x 7 ” (95 x 190mm) hole in wall (See template on page 35) Flush mount box Case back panel 4x control module back panel screws Controller Qt Conference Room Edition Installation and Operations Guide page 18...
  • Page 12 Controller Wall hole 3-gang EU/UK wall box (not included) Wall plate adapter 6 x screw (not included) Case back panel 4 x #6 self-threading screw Controller Qt Conference Room Edition Installation and Operations Guide page 19...
  • Page 13 After all cables have been attached, snap the controller in place. After installation, the controller can be removed by pulling it, and it will snap away from its back, exposing the cabling and also giving access to the mounting points. Qt Conference Room Edition Installation and Operations Guide page 20...
  • Page 14 (not included) 2x privacy sign screws Wall plate Privacy sign Wall hole 1 gang EU/UK wall box (not included) 2x privacy sign screws Wall plate Privacy sign Qt Conference Room Edition Installation and Operations Guide page 21...
  • Page 15 Connect the cable using the push terminals. Peel the double sided tape and attach the panel. Hole in wall for wire (see template on page 37) Self adhesive pad Privacy sign REMEMBER TO CHECK ALL CONNECTIONS AND CONFIRM PRIVACY SIGN OPERATION BEFORE ATTACHING TO WALL Qt Conference Room Edition Installation and Operations Guide page 22...
  • Page 16 Note: The hider plate is ABS plastic and may be painted to a desired color if needed. Use a standard spray primer (Krylon) before painting. Hider plate Self-adhesive pads Self-adhesive pads Glass surface Privacy sign Wire Qt Conference Room Edition Installation and Operations Guide page 23...
  • Page 17: Settings Record

    Z O N E D E STI N ATI ON RE COR DS Zone Destination Record Zone 1 Run 1 Run 2 Settings Record Volumes: Zone: Masking: Input A: Installation / Service: Company name: Install date: Phone: Qt Conference Room Edition Installation and Operations Guide page 34...
  • Page 18 H O L E CUT G UID E F OR FL US H MO U NT B OX Qt Conference Room Edition Installation and Operations Guide page 35...
  • Page 19 Qt Conference Room Edition Installation and Operations Guide page 36...
  • Page 20 Hole shape is not important, but be careful to stay within area to be covered by sign. REMEMBER TO CHECK ALL CONNECTIONS AND CONFIRM PRIVACY SIGN OPERATION BEFORE ATTACHING TO WALL Qt Conference Room Edition Installation and Operations Guide page 37...
  • Page 21 Cambridge Sound Management, Inc. 404 Wyman St. Suite 200 Waltham, MA 02451 USA cambridgesound.com © Copyright 2015 Cambridge Sound Management Inc. Quiet Technology, Qt, Cambridge Sound Management, and the logo are trademarks of Cambridge Sound Management.
  • Page 22 This two page document is an addendum to the Qt Conference ® Room Edition manual. Please read. NOTE: Below are supplemental images for the content contained on page 14 of the Qt Conference Room Edition manual. ® Connection to privacy signs Run a separate cable from the controller mounting location to each lighting location.
  • Page 23 This two page document is an addendum to the Qt Conference ® Room Edition manual. Please read. NOTE: Two new options have been added to the program menu of the Conference Room Edition. These options are outlined below: ® 1. Contact Closure = Normal/Off or Normal/Low. When this option is set to “Normal/Off”, the contact switch will toggle between Normal Volume (Contact Open) and Off (Contact Closed).