2. Pair the Temperature Sensor with the Control-R™ Module (called Pairing Mode) by following the steps below.
IMPORTANT: You have 5 minutes to pair the Temperature Sensor with the Control-R™ Module before Pairing Mode times
out. If Pairing Mode times out, you must repeat the steps below.
On the Control-R™ Module, press and hold down the "Connect" button until
the LED turns green. Then, release the button.
The Temperature Sensor LED light flashes once every 5 seconds to indicate the
Temperature Sensor is not paired with the Control-R™ Module. To enter
Pairing Mode, press and hold the "Connect" button on the Temperature
Sensor PCB until the LED double-flashes. Then, release the button.
When the Temperature Sensor successfully pairs with the Control-R™ Module,
the Temperature Sensor LED will remain on for approximately 5 seconds and
then turn off. The Control-R™ Module LED flashes green and then returns to
the previous mode (Blue = connected to Internet; Red = not connected to
Internet). A small delay is normal when the module is flashing green and
returning to its original mode.
The Temperature Sensor is now paired with the Control-R™ Module.
3. Rotate the front cover to close the Temperature Sensor Transmitter. Use a Phillips screwdriver to secure the three remaining
screws to the front cover.
4. Temperature Sensor pairing is complete.
5. Select a location to install the Temperature Sensor Transmitter (read the Installation Requirements section above before
selecting a location).
6. Install the Temperature Sensor Transmitter by mounting the flat portion of the sensor securely
against the selected location (copper pipe, shutoff valve, etc.). The adhesive strip should fit firmly
around the location. When the sensor is in the correct location, tighten the plastic cable tie to
secure the sensor in place.
Restore Factory Settings
To restore the Temperature Sensor settings to a fresh state:
1. Remove the Temperature Sensor battery.
2. Press and hold the "Connect" button on the Temperature Sensor PCB while reinserting the battery.
3. When the battery is inserted, release the "Connect" button. The Temperature Sensor LED will turn on.
4. When the Temperature Sensor resets successfully, the LED will turn off.
5. The LED will begin to flash every 1 second to show the Temperature Sensor is in an idle state and is
ready to be joined to a network.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION
©2016 Rinnai America Corporation. Rinnai America Corporation continually updates materials, and as such, content is subject to change without
notice. Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation.
LED
Connect button on
Control-R™ Module
Connect button on
Temperature Sensor
Transmitter
Connect button
100000423(01)
9/2016

Advertisement

loading