C-Data HF300-3815C-22D User Manual

1550nm erbium-doped fiber amplifier

Advertisement

Quick Links

User's manual
1550nm Erbium-Doped Fiber Amplifier
HF300-3815C-22D
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for C-Data HF300-3815C-22D

  • Page 1 User’s manual 1550nm Erbium-Doped Fiber Amplifier HF300-3815C-22D User’s Manual...
  • Page 2 User’s manual...
  • Page 3: Table Of Contents

    User’s manual Content 1. Safety instructions ...................... 1 2. Production structure description ................2 2.1 Equipment dimension ..................2 2.2 The front panel diagram ..................2 2.3 The rear panel diagram ..................2 3. Operation instructions ....................3 3.1 Connection ......................3 3.2 Turn on/off procedure ..................
  • Page 4: Safety Instructions

    User’s manual 1. Safety instructions Before installing and using products, please read the following carefully. The company shall not be responsible for any loss caused by any breach of safety. The output of the laser and erbium-doped fiber amplifier is high-power invisible radiation.
  • Page 5: Production Structure Description

    User’s manual input and output optical port of EDFA, please cover dust-proof cap to prevent the input and output end from being contaminated. 2. Production structure description 2.1 Equipment dimension Adopting the 19" standard 1U chassis: 485mm (length) X298.13mm (width) X44mm (height).
  • Page 6: Operation Instructions

    User’s manual 3. Operation instructions To ensure the normal operation of EDFA, you must operate in accordance with the following methods: 3.1 Connection  Ensure that the device is well grounded;  Measure input optical power, confirm within the EDFA input optical power range, check the input and output optical fiber connector whether is consistent with EDFA optical interface connector, and cleaning the connector ends;...
  • Page 7: Button Description

    User’s manual Various alarm status LED flash red lights.  Remote monitor and control When the external computer and EDFA are connected, you can view the working parameters of the device through the Web page. First, input the 192.168.1.100 (default IP address) in the browser's address bar, second, click the “enter”, and enter the login page to input the default username "admin", and the password "admin".
  • Page 8 User’s manual N P U T P W R 0 0 d B m If input optical power is below -15.00dBm, the second line can display “NO INPUT” N P U T P W R N P U T Press “NEXT” button, then jump ③to display. ③...
  • Page 9 User’s manual C U R R E N T 1 0 0 0 0 m A Press “NEXT” button, jump ⑤ to display. ⑤ Display TEC refrigeration / thermal current interface, as shown below: T E C C U R R E N T 2 0 A Press “NEXT”...
  • Page 10 User’s manual P W R A L A R M Press “NEXT” button, jump ⑧ to display. ⑧ Display Internal temperature of the chassis interface, as shown below: N T E R T E M P E R A T U R E T 0 °...
  • Page 11 User’s manual Press “NEXT” button, jump ⑬ to display. 13 Display manufacture date interface, as shown below: M a n u Press “NEXT” button, jump ⑭ to display. 14 Display online time, as shown below: x x x x D a y s x x H o u Press “NEXT”...
  • Page 12 User’s manual M A S K A D D R 2 5 5 2 5 5 2 5 5 0 0 0 Press “NEXT” button, jump ⑰ to display. Press “ENTER” button, enter subnet mask setting interface. Current modified bit will flash.
  • Page 13: Alarm Breakdown Analysis

    User’s manual 18 Display restore factory setting interface, as shown below: R E S T O R E F A C T O R Y C O N F Press “ENTER” button, jump ① to display. Press “ENTER” button, enter restore factory confirm interface. C A N C E L A F F Press “NEXT”...
  • Page 14 User’s manual Check environment 1. Pump laser characteristic change temperature is too high. Pump current change a 2. Internal circuit detection The working temperature lot, pump current alarm deviation chassis within 3. Pump laser damaged 0-50℃. Usually, when the 1. Internal circuit detection Pump...