FracSim Meters FracSim mini Operator's Manual

Advertisement

Quick Links

Operator Manual 1.4
FRACSIM MINI

FracSim Meters

FracSim Meters was founded with the intention of
providing specifically designed tools for the well service
industry. Our goal is to provide quality tools with a robust
design to meet the needs of well service technicians. If you
have any questions or concerns please contact us at:
FracSim Meters
Grande prairie Alberta
(780) 882 2546
or
www.fracsimmeters.com
For additional information on different products or
instructional videos on how to use the FracSim meter please
visit the website.
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FracSim mini and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FracSim Meters FracSim mini

  • Page 1 FracSim Meters FracSim Meters was founded with the intention of providing specifically designed tools for the well service industry. Our goal is to provide quality tools with a robust design to meet the needs of well service technicians. If you have any questions or concerns please contact us at: Operator Manual 1.4...
  • Page 2: Table Of Contents

    Table of Contents Specifications: FracSim Meters ................2 Specifications:................4 Selecting and using batteries: ............5 Cold weather operation: ............... 5 Warnings: ..................6 Using this manual: ................ 7 Using the interface turn knob: ............7 Main Menu: .................. 8 Voltage Measure:................
  • Page 3: Selecting And Using Batteries

    Selecting and using batteries: Warnings: The FracSim meter uses a switching power supply and can accept Do not open the case: battery voltages from 6.5 to 20 volts. The higher the voltage, the less current it draws due to the switching power supply. Using the Opening the case beyond the battery compartment will void supplied battery holder you can use 2 X “9V.
  • Page 4: Using This Manual

    Using this manual: Main Menu: When using the manual please note the following: MEAS<= V DC To measure voltage / mV DC This icon marks all the pin outs for each function. All To measure mA measurement function use the "Red Socket" To measure frequency / scope view (positive)"...
  • Page 5: Main Menu

    Voltage Measure: Diode Measure: The FracSim meter will measure voltage drop across a diode. To The FracSim meter will measure -30V to 30 V DC. To access voltage MEAS<= access diode measure mode from the main menu select MEAS<= measure mode from the main menu select and V DC .
  • Page 6 Current Simulate Functions: Frequency Simulation Function: The FracSim meter can sink or source 0 up to 22mA while The FracSim meter will simulate an AC / DC square wave frequency simultaneously measuring loop voltage. To access the current from 1 to 5000 Hz with a range from 0 to 18 volts (maximum is proportional to battery voltage).
  • Page 7: Frequency Measure

    Serial Data Functions: DAT => The FracSim meter can read and write RS 485 ASCII data @4800, Select the baud rate. The screen will display the same data that is 9600, 19200, 38400, 57600. The data output can either by in WITS or being outputted.