Thank you for choosing the most environmentally friendly way of disposing of your food waste. Remember at the end of the machines life we can collect it and recycle it. Operating and Installation Manual MAYFAIR CHELSEA CHELSEA-PLUS VICTORIA KENSINGTON WESTMINSTER...
Page 2
Guarantee This Guarantee is subject to the following conditions: The Guarantee is valid only if the serial number attached to the unit is not defaced in any way. The Guarantee will be void if the unit is dismantled by any person other than an authorised Dealer or Service Agent.
Twe e ny Guarantee Registration card Please complete the registration card within 30 days, return complete with a copy of proof of purchase to receive your extended manufacturers warranty. To fi nd out more about our range of accessories including air switches, gold and brass sink outlets please tick: Name: Address:...
Page 4
Please fold here and seal FREEPOST SEA 11333 Hastings TN35 4BR...
Page 5
Installing the suspension unit - all models (excluding Westminster - see page 16) Fitting the waste disposer - all models (excluding Westminster - see page 16) 10. Fitting the actuator - Mayfair model only 12. Electrical installation - all models (excluding Westminster - see page 18) 13.
Model identifi cation Westminster Mayfair Chelsea Kensington Victoria 125-X...
Page 7
User instructions You have just purchased a Tweeny food waste disposer and we want it to give you satisfaction and prove a useful asset to your home. Tweeny will swiftly dispose of all wastes such as tea-leaves, vegetable peelings and plate scraps.
Page 8
User instructions Remove the strainer. Run cold water freely and switch on the unit. Feed in food waste through the tongued Switch off the unit and turn off water splashguard using spatula supplied. shortly after grinding has ceased. Replace the strainer.
Page 9
Controls The MAYFAIR is controlled via the actuator which, being non-electric, can be situated close to the taps or wherever is most convenient, it is not to be used, though, as a footswitch. The green light indicates that the unit is operating.
180mm from the vertical. This must be taken into consideration when arranging the radial position of the suspension plate, i.e. the hinge must be positioned at the front. Minimum space required between underside of sink and top of plinth: Mayfair and Chelsea: 475mm Victoria and Kensington: 415mm Westminster: 480mm 125: 460mm The unit must drain completely.
Page 11
Installing the suspension unit all models except Westminster Rubber washer Sink outlet Suspension plate Wing nut Seal Allen screws Circlip Carrier plate Hinge pin Ensure bottom of sink is smooth, clean and dry. Remove the sink outlet assembly from the pack. Using the allen key provided, unscrew the four screws until they are just below the top face of the suspension plate.
Page 12
Fitting the waste disposer all models except Westminster Before mounting the disposer ensure that the hinge faces the front. The unit is supplied with a right hand outlet, though machines can be supplied with a left hand outlet. A right hand outlet machine can be made into a left hand outlet machine simply by unscrewing and re-aligning the carrier plate.
Page 13
Swing the unit up into position and tighten the wing nut. Slightly rotate the disposer as necessary on the circlip until the elbow is in correct alignment with the drainage fi ttings. Mark position of the suspension plate relative to the sink and remove the disposer. Tighten up the four allen screws in the suspension plate.
Page 14
Fitting the actuator Mayfair model only The self reversing actuator has also been designed for ease of installation. By squeezing and lifting the base of the wall of the push-button below the pimpled surface, the push-button will come out, exposing the bellows and the two fi...
Page 15
Connecting the actuator The fi bre-optic light guide terminates in a brass ferrule at each end. This is fi rst plugged into the socket on the back of the actuator housing which has the window on the facsia plate. Light lubrication of the ferrule will assist its insertion if necessary. The pneumatic tube is passed through the back of the actuator housing and plugged into the bellows (See fi...
Electrical installation The fuse to be fi tted must be of a 10A rating. This appliance must be installed in accordance with IEE regulations. The unit must be connected to the supply by means of a non-detachable fl exible cord or by wires in a fl...
Page 17
Service Arrangement Please call 01424 751888 for your nearest Service Agent. You will need to quote the serial number. If the service is needed because of: Misuse, poor installation or accident, i.e. a jammed condition you are unable to free yourself, then the agent will clear it and charge you accordingly based on the agent’s time and distance.
Page 18
3. Remove the de-jam key. 4. Repeat steps 4 to 7 above. IF THIS FAILS 1. Check that your power supply is not fused and that your air switch or wall switch is working. 2. Contact Tweeny on 01424 751888 for more help.
Page 19
Don’t run for long periods, this is a domestic machine which can run for 10 minutes maximum at any one time. CLEANING Using plenty of water when disposing of waste will keep the unit clean. Alternatively, use a sachet of Disposer Care available from Tweeny.
Installation Instructions Westminster model only Step 1 - Fitting the sink bush assembly (See Fig. 1c-Stage 1). 1. Remove the sink bush assembly from the unit by fi rst loosening the three-nuts (9), and twisting the assembly clockwise in the hopper fl ange keyholes. Slacken off the three-grub screws (7), suffi...
Page 21
13. Ensure grub screws are 90 degrees to the clamp plate. 14. Place a straight edge (metal ruler) across the bottom of the sink bush to check that the bottom face is parallel to the suspension plate. 15. Repeat at 90 degrees and adjust the grub screws as required. Step 2 - Fitting the unit to the sink bush assembly (Fig.
Page 22
Standard sink bush will accommodate up to a 20mm thick sink, for thicker sinks a range of extended sink bushes are available. Please contact Tweeny for details. Suffi cient space within the cabinet is required to allow easy access to the disposal units controls. The unit is provided with a 38mm diameter outlet bend to which a suitable ‘P’...
Page 23
The waste pipes should not be less than 38mm diameter and laid with a minimum fall of 15 degrees. The run should be as short as possible, avoiding sharp bends, tee connections and stopped ends. The waste should not discharge over a gulley or drain grating. Where a lengthy, or meandering run pipe work is unavoidable, it is recommended that the pipe size be increased to 54mm diameter immediately after the trap.
Page 24
Tweeny manufactured in England Kingfi sher House, Wheel Park, Westfi eld, East Sussex TN35 4SE Telephone: 01424 751888 Fax: 01424 751444 Website: www.tweeny.co.uk Email: sales@tweeny.co.uk...