About this Manual About this Manual Products Covered This manual provides information for the installation and operation of the Snell IQH3A 3U modular enclosure fitted with the RCIF3U2C Gateway Card. Software Version This unit is fitted with software version 5.19.19.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Safety Notices Products Employing Lithium Batteries This equipment contains a lithium battery. There is a danger of explosion if this is replaced incorrectly. Replace only with the same or equivalent type. Dispose of used batteries according to the instructions of the manufacturer.
• fit the unit using the rear rack mount kit available from Snell by quoting the order code FGACK RACK-MNT-KIT. Replacing the Gateway Card If the Gateway Card IQRCIF is replaced ensure that the part number of the card is RCIF3U2C to enable the chassis monitoring facility.
Please refer to the Technical Specification section of the product operation manual. EMC Performance of Cables and Connectors Snell products are designed to meet or exceed the requirements of the appropriate European EMC standards. In order to achieve this performance in real installations it is essential to use cables and connectors with good EMC characteristics.
Product Support Providing Information to Snell If you experience any technical or operational difficulties with a Snell product please do not hesitate to contact us to request assistance. There is a lot of information you can give us that will enable us to diagnose your problem swiftly.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Product Support Customer Support Contacts Snell’s contact details can be found at the Snell website at: www.snellgroup.com/support United Kingdom (HQ) +44 (0) 118 921 4214 (tel) +44 (0) 118 921 4268 fax) customersupport@snellgroup.com Regional Support Contacts...
1. Introduction 1.1 Unit Description IQH3A enclosures offer industry leading, high-density delivery of modular solutions. The 3U rack unit accepts up to 16 modules. Single and dual PSU versions with cooling fans are available. RollCall control and monitoring is included as standard using a Gateway control card that has its own module style rear connector, thus providing a future proof upgrade path as communication standards evolve.
141 W* 165 LU* * On the IQH3A, power is quoted in Watts and is the sum of both positive and negative rails. On the IQH3B, power is quoted in Load Units (LU), which refers to power taken from the positive rail.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3. Installation 3.1 Unpacking the Unit The unit is supplied in a dedicated packing carton provided by the manufacturer and should not be accepted if delivered in inferior or unauthorized materials. The contents of the carton are: •...
Each IEC connector supplies an independent feed of power to each of the two power supply modules as shown in the diagram above. The IQH3A IQ 3U Modular Enclosure can support dual power supplies for redundancy; however, this is an option, therefore a second PSU may not be fitted.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3.5 Front Panel Indicator On the front-panel, there is a bi-colored (red and green) LED that indicates the unit’s status. LED Indicator LED State Meaning Power ON Green OK – no faults detected...
This connector may also be used as a RS-422 or as a RS-232 RollCall communication port. RS-485 interconnections should be pin-to-pin and only be used for Snell RollNet Note: applications. The supplied 9-way serial extension cable is only used for the initial setup of the Gateway Important: controls by qualified installation personnel.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3.6.3 Status Monitoring circuitry built in to each PSU reports power failures via isolated relay contacts on the STATUS connector (9-pin D, female) on the frame rear panel. Any circuit connected to this status connector shall be a SELV circuit as defined in EN60950.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3.6.4 RollNet The BNC connector enables the unit to be connected to the RollCall network communications system. The RollCall system should be connected using a 75 Ohm “T” or “Y” piece, in a similar manner to an “Ethernet”...
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3.7 Opening and Closing the Front Panel To open the front panel: Turn the locking screw approximately half a turn to release the panel. Pull the panel forward and downward using the grip handles.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3.8 Power Standby Switches The standby switches are located behind the handle on the front panel of each power supply. Power ON is indicated by the illumination of LEDs V1 and V2. 3.9 Power LEDs...
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3.10 Front (Gateway Card) Controls and LEDs Front Panel connectors, controls and LEDs are provided by the Gateway Card, fitted into a dedicated slot in the 3U enclosure. 3.10.1 Front Panel Connector This connector connects to the front panel AND provides the drive power to the LED on the front panel.
Gateway Card Module Slots 1 to 16 The dual power supplies of the IQH3A 3U Enclosure are designed to accept one or two SPX0149 power supplies with independent IEC320 mains inlets. Individually, each PSU module is capable of powering the IQM 3U frame containing any combination of IQ-1A modules subject to Configuration Rules.
The IQH3A 3U Enclosure is provided with one PSU as standard. There is an option for installing a second PSU to allow dual redundant operation. This may be a factory fitted option or can be done as an upgrade.
Snell Web site. 3.13.1.2 Available Power The IQH3A IQ 3U Modular Enclosure has 141 Watts of available power. The Power Ratings of each module should be added together and the total should not exceed 141 Watts.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3.13.2 Installing a New Module Ensure that the power supply is switched OFF and the mains power connection at the rear of the unit is removed before this operation is performed. Before installing a new module consult section 3.13.1 on page 27 and ensure there is adequate power available for the module to be added.
Installation 3.13.4 Replacing a Module in a Live Environment Snell recommends that the power supply is switched off and the mains connections are removed before performing the previous operations. However, in a live environment, this may not be possible and you can remove and install modules without switching the power off.
The IQH3A IQ 3U Modular Enclosure has various interface connections to the RollCall network: • RollNet 75 Ohm coaxial BNC running at 2.5 Mbps. The IQH3A IQ 3U Modular Enclosure represents a 2 unit load. • RollNet RS-485 9-way, D-type connector running at 2.5 Mbps.
Page 31
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation Mode SW1 1-7 SW1 8 SW7 1-4 RS-232 OPEN ----- CLOSED RS-422 CLOSED CLOSED OPEN RS-485 CLOSED OPEN OPEN Gateways ship with a default setting of RS-232. 3.15.1.2 RollNet 75 Ohm Coaxial Interface This interface allows connections of units to a single section of 75 Ohm video cable.
The serial port can also be used for third party connections into the system. This allows PCs or any other serial device access to any of the units within the system. Please consult Snell for details of the port binary protocol.
Page 33
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation A PC can control multiple RollCall networks by connecting via RollProxy. 3.15.2.1 Configuring IP Parameters You must configure the Gateways IP parameters before you can connect to the Gateway using IP over Ethernet. To do this you must establish a connection to the Gateway using a different communications interface.
SNELL-WILCOX-PRODUCT-REG.MIB (Id for each card type) SNELL-WILCOX-UNIT.MIB SNELL-WILCOX-GATEWAY-LOGGING.MIB (card and gateway logging tables) SNELL-IQH3A-CMD-MIB.MIB (gateway controls) SNELL-WILCOX-MODULAR-GATEWAY.MIB (required if legacy SNMP support is enabled). This is a hierarchical MIB structure and must be compiled in order if your SNMP manager does not support conditional compilation.
To control modules within a chassis you would also need the MIB for that card type: SNELL-cardIdName-CMD-MIB.MIB where cardIdName could be IQCBRG for a Bridge card or IQDMSDA, or other card names etc. MIBs are available from the Snell website: Legacy MIBs (required): ftp://ftp.snellwilcox.com/RollCall/SNMP_MIBs/Legacy_IQ_Modular_MIBs/ Modular (as required): ftp://ftp.snellwilcox.com/RollCall/SNMP_MIBs/IQ_Modular_MIBs/...
Page 36
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Installation 3.15.4.1 Configuring IP Bridging An IP bridge requires two Gateways, both connected to the IP infrastructure and set to RollCall addresses in the range 0x01-0x0F. An example configuration might be: Gateway 1 Gateway 2 Ethernet ->...
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4. Operation This section of the manual assumes that the IQH3B Enclosure has been installed in accordance with the instructions given in the Installation Manual. It describes the operation of the unit by means of the RollCall Control Panel software.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.1.3 Line 3 This line will show the status of the enclosure cooling fan which is located at the rear of the unit. It displays the status and the programmed speed (devised according to the current ambient...
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.2 Setup The Setup screen enables various system functions to be configured. 4.2.1 Unit Name This field enables the unit to be given a meaningful name. To enter/modify the name of the unit, type directly into the editable text field and click the Save (S) button. To return to the default name, click the Preset (P) button.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.2.3 Hardware Version This displays the version number of the hardware used in the Gateway Card. 4.2.4 Enclosure This displays the IQ Modular enclosure type that the Gateway is fitted in. 4.2.5 Software Version This displays the software version installed.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.2.13 Module Upgrades These controls temporarily suppress backplane logging and thumbnailing. They are only used by RollMechanic and the Control Panel, and do not need to be changed by the user. • Reset Timer: This resets the timer, used when upgrading a module.
408. Leave disabled (short) unless advised by Snell engineering. 4.2.18 Fan Speed Override This control only appears in IQH3A products where the backplane is of an old design. This control is hidden for newer chassis types. A temperature sensor is located at the rear fan. For older chassis that had the rear temperature sensor connected through the module i2c bus, this control has been added to allow user to override the fan speed.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.3 Ethernet The Ethernet screen enables networking functions to be configured. Altering any of these settings while connected to the Gateway via IP may result in the Note: connection being lost. If the new values are incorrect it may not be possible to reestablish the connection via IP and a connection via RollNet or the serial port will have to be made to correct the settings.
This item will show the MAC address, which is a globally unique number identifying an Ethernet unit. Note 000581 is the Snell OUI number. Ignore Broadcast Packets should only be checked if it is possible to resolve IP address to Important: MAC addresses without using the ARP protocol.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.4 RollCall IP The RollCall IP screen reports various statistics about IP share connections and allows configuration of the IP bridge function. 4.4.1 Enable Stats If the Enable Stats box is checked then the various packet counters will be constantly updated.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.4.3 IP Share Port • Full Network: The Gateway will accept IP Share connections on this IP port number. The default is 2050. To enter/modify the full network port number, enter the new number in the editable field and click the Save (S) button.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.4.6 RollCall IP History The Gateway may reject IP connections if they do not match the client address set or if the limit on IP connections has been reached. • Last Rejected Client: This shows the IP address of the last client that the Gateway rejected.
Page 48
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation Pass I_AM (Bridge) overrides both Pass I_AM (Serial) and Pass I_AM (IP). So if Pass Note: I_AM (Bridge) is set I AM messages will be passed over the bridge, irrespective of how the other controls are set.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.5 Log Server This Log Server screen enables the characteristics of the logging server to be specified. 4.5.1 LogServer The Logging Server to be used may be named by editing the text string in the text window. To enter/modify the name of the logging server, enter the new name in the editable text field and click the Save (S) button.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.5.8 Accept logserver via Serial If this is selected, the Gateway will accept servers packets via the serial port. 4.5.9 Accept logserver via Bridge If this is selected, the Gateway will accept servers packets via the bridge.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.6 Slots (1-4), (5-8), (9-12), and (13-16) The Slots screens allow each slot to be named and interrogated. 4.6.1 Name The Name section displays the name and type of module fitted in the enclosure slot. See 4.6.6 Examples of Slot Use on page 54.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.6.2 Type This displays the unique identifier of the module fitted in the slot. See 4.6.6 Examples of Slot Use on page 54 Bound Type ID Preset Save Installed Unit ID The following controls are provided: •...
If a module's ID is not recognized the power usage will indicate ??. If this occurs please contact Snell customer service to obtain the correct power usage value. Some IQ Modular cards do not appear in the port listing (eg SDA31/33). In this case the Non Rollcall Enable check box should be enabled, and the type added in the IDNAME field.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.6.6 Examples of Slot Use 4.6.6.1 Intentionally Empty Slot If a slot is intentionally left empty, the Installed Unit Name field will show No Unit Fitted and the Installed Unit ID field will show No Unit.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.7 Control (1-8) and (9-16) The Control screens display information about the controllers for each slot. 4.7.1 Update Packet Stats When the modules receive commands from control clients the number of commands are counted.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.7.3 Slots 1 to 16 These sections display information about control clients. Active Front Panels and RollCall PC programs use a RollCall connection to control a module. RollTrack does not use a connection, it uses Blind control. Blind Control is the ability to control a unit without a connection.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.8 Gateway Control This Gateway Control screen provides information about control clients connected to the gateway unit itself (not to modules inside the enclosure). Note if SNMP is enabled, one of the sessions is looped back to itself.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation • Address: Last known blind controller address. This value is cleared by clicking the Clear Packet Count button. • Packet Count: The number of blind control packets since last cleared / reset. 4.8.3 Statistics Control •...
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.9 SNMP (Simple Network Management Protocol) The SNMP screen enables configuration of the SNMP agent that operates within the Gateway card. In order for the SNMP to operate, the Ethernet must have a physical connection available.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.9.3 Read community Configures the SNMP read community value. Default value “public”. 4.9.4 MIB2 sysContact Customer given name of person responsible for equipment. 4.9.5 MIB2 sysLocation Customer given physical or logical location of system.
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.10 Logging 1 The Logging 1 screen shows the information made available via RollCall logging, and allows the user to specify which fields will be logged. Each log field is shown on a separate line. Each has an enable check box, a descriptive name, the log field header and the current value.
Page 62
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation Field Name Field Name Description Valid Field Values Usage Description LOADER_VERSION= Loader Version Version Number For example, 2.17 .7. IPADDRESS IP Address WARN: None No IP Address Specified WARN: Invalid Address Invalid address, subnet or gateway value specified.
Page 63
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation Field Name Field Name Description Valid Field Values Usage Description LAN_PORT_n_LAST_CHANGE Time from start since last Port Change Number Time change when IP interface parameters altered (ie IP subnet) DDD:HH:MM:SS Uptime in specified format updated...
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation 4.11 Logging 2 The Logging 2 screen shows the information made available via RollCall logging, and allows the user to specify which fields will be logged. Each log field is shown on a separate line. Each has an enable check box, a descriptive name, the log field header and the current value.
Page 65
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation Field Name Field Name Description Valid Field Values Usage Description TEMP_1_NAME Name of temp sensor TEXT Function name such as Temperature In, Temperature Out TEMP_2_NAME Internal Temperature, PSU 1 Temperature, etc. These are set by the product and are not user settable.
Page 66
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation Field Name Field Name Description Valid Field Values Usage Description THUMB_IP_PORT Thumb IP Port value NUMBER Reports the IP Port number used for Hyperion Thumbnail monitoring. Ensure enabled if Hyperion monitoring uses the auto discovery feature.
Operation 4.12 Statistics The Statistics screen displays any errors that may occur within a system. In the event of a problem, these error messages may be quoted to Snell customer support to assist debugging. 4.12.1 Statistics The following items are displayed: •...
Page 68
IQH3A IQ 3U Modular Enclosure www.snellgroup.com Operation • Number of unit loads per segment exceeded* *Please refer to RollCall System Integrators Manual. • Module Comms Errors: This counts errors on the I2C bus. • BackPlane Rx: This counts the bytes/second of RollCall traffic received down the Backplane.
Instruction Manual. The RollCall Control Unit may also be opened as an application by clicking the RollCall Control Panel icon on the desktop or clicking Start > All Programs > Snell > RollCall > Control Panel (Windows XP). To open the RollCall Control Applet: Open a new Web Browser window and enter the IP address of the gateway (e.g.
Page 71
IQH3A IQ 3U Modular Enclosure www.snellgroup.com RollCall Control Applet A Java screen and a Warning - Safety dialog will be displayed. In the Warning - Security dialog, place a check mark in the Always trust Content from this publisher check box, then click the Run button.
Page 72
IQH3A IQ 3U Modular Enclosure www.snellgroup.com RollCall Control Applet Right-click on the relevant chassis to select it and display a context menu, then select the Connect option to download the RollCall template screens. After a few moments, the screens for the selected chassis are downloaded to the RollCall Control Unit window and the top-level Setup screen is displayed in the Template Display Area on the right-hand side.