Thank
you
for
Thermo-Checker,880D is a special designed for
monitoring forehead temperature range 30℃ to
0
50 ℃ (86 to122
F). Quick response, without
waiting! Safe and hygienic, without contacting.
Auto power off saves power!0.1℃ resolution for
more accurate reference.
[WARNING]
To get an accurate reading, the best operating
ambient temperature range is around room
temperature 25 degree ℃+/-2℃.
Keep your forehead dry and clean, no hair is
covering to get the accurate measurements.
Do not immerse the product into water or
other liquid.
Do not use a sharp thing to touch the sensor
lens.
Do not use this product for Live and Die or
Fever decision. The data is only for tracking
reference,
If
you
35.8-38degree ℃,double check with a clinical
thermometer.
It's important to study all instruction and
warning before using.
Thermal shock(cause by large or abrupt
ambient
temperature
minutes for unit to stabilize before use).
Recommend to clean the lens after a time of
period using the device to ensure the reading
accuracy.
By using low pressure compressed air to remove
any particles on the lens.
using
this
Infrared
find
a
temperature
changes
allow
20~40
Any swab pressure be should be damp, and very
light pressure should be applied to the lens. Do not
use solvents to clean the lens.
[PARTS DESCRIPTION]
1. Trigger: When pulling the trigger LCD
display reading. Release the trigger, display
reading with HOLD icon.
2. Flashlight on/off button:Pressing the button
turns the Flashlight on, pressing it again turns it
off.
3. Celsius/Fahrenheit switch button.
4. Back light on/off button: Pressing the button
turns the backlight on, pressing it again turns it
off.
5. Battery door: When replace battery door,
please using the finger indents to pull open the
battery door.
[OPERATION]
1. Reminder before using:
please measure under room temperature around
25℃~30℃,recommend not to use under strong
heat or cooling room. and make sure the
measurement area is clean and dry. Better not to
measure in 10 minutes after sports, shower or
heavy sweat to get accurate measurement.
2. Measurement
Aiming toward the forehead you want to measure
as near as 1-2cm(not to touch),press the trigger,

Advertisement

loading

Summary of Contents for Veto 880D

  • Page 1 Thank using this Infrared reading with HOLD icon. Thermo-Checker,880D is a special designed for 2. Flashlight on/off button:Pressing the button monitoring forehead temperature range 30℃ to turns the Flashlight on, pressing it again turns it 50 ℃ (86 to122 F). Quick response, without off.
  • Page 2 you will get the reading on LCD display. won’t be referred. “Lo”or “Hi” error message will appear once the measurement exceeds the temperature range. KEEP IN MIND THAT IT WILL TAKE UP TO 20 MINUTES TO ADJUST TO WIDE AMBIENT TEMPERATURE CHINGES.