Salcom 12-32-0000 Product Manual

32 port input expansion module

Advertisement

Quick Links

12-32-0000
32 Port Input
Expansion Module
PRODUCT MANUAL
Version 1.00
April 2017
Copyright © 2017 Sea Air and Land Communications Ltd. All rights reserved.

Advertisement

Table of Contents
loading

Summary of Contents for Salcom 12-32-0000

  • Page 1 12-32-0000 32 Port Input Expansion Module PRODUCT MANUAL Version 1.00 April 2017 Copyright © 2017 Sea Air and Land Communications Ltd. All rights reserved.
  • Page 2 P a g e Salcom Product Documentation This document is designed to familiarise you with Salcom products and guide you through the hardware, configuration, installation and overall system management. Salcom is an environmentally conscious company and in an effort to conserve paper no longer prints manuals with shipped products.
  • Page 3: Warranty And Disclaimer

    P a g e Warranty and Disclaimer Salcom products are warranted for a period of 12 months from the date of purchase against faulty materials and workmanship. Should any fault occur the unit should be returned to the vendor, freight pre-paid. Please include a description of the fault to assist with prompt return.
  • Page 4: Product Overview

    P a g e Product Overview The 12-32-0000 is a 32 input expansion module that may be used either autonomously with a serial to ethernet converter or with any transmitter that supports Salcom protocol. Input modules may be daisy chained together to provide as many inputs as required.
  • Page 5: Installation And Connections

    Not Used Not Used Not Used Not Used RS232 Tx RS232 Rx RS232 Rx RS232 Tx 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand April 2017...
  • Page 6 This RED LED flashes to indicate serial data is being Transmit Data transmitted to a downstream device 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand April 2017...
  • Page 7: Operation

    The input module may be configured to operate without acknowledging, so that input modules may be connected to a PC or unit that does not support Salcom protocol (but this is not advised, since messages may be lost).
  • Page 8 The watchdog feature will initiate an action after a predetermined period. The watchdog also optionally allows the transmission of the current state of selected inputs (including supply level). 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 9 P a g e Connecting Multiple Input Expansion Modules System Configuration using multiple Input Modules 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand April 2017...
  • Page 10: Error Codes

    The downstream device failed to acknowledge the last sent message ER6 BUSY 12-32 is too busy to process the received message – memory is full 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 11: Troubleshooting

    Device is busy - memory is full or transmitter unable to clear volume of messages. Green led flashes rapidly Low supply detector threshold 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand April 2017...
  • Page 12 Once the program is running, the opening screen appears. Use the mouse to select the configuration fields for each feature. 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 13 Transmission Count: How many times that message will be sent if triggered. Enabled: When selected, the configured message will be sent when triggered. 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 14 The current 12-32 configuration can be saved using File-Save. Previously saved configuration files can be loaded and edited with, or without a 12-32 connected. 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand...
  • Page 15: Technical Specification

    9600 baud no parity, 8 data bits, 1 stop bit Discrete Inputs Pulled up to +12V (10K) Number Inputs Enclosure 193mm x 113mm x 50mm 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand April 2017...
  • Page 16: How To Contact Us

    P a g e | 15 How to Contact Us Sea Air and Land Communications (Salcom) Ltd 10 Vanadium Place Addington Christchurch 8024 New Zealand +64 (0)3 379 2298 W: www.salcom.com support@salcom.com 12-32-0000 32 PORT INPUT EXPANSION MODULE Product Manual...