Download Print this page

Orient Detectors Titan Ger 1000 User Manual

Gold and metal detector

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for Orient Detectors Titan Ger 1000

  • Page 2: Imaging System

    English User Manual TITAN GER 5 Systems in 1 Device PULSE INDUCTION SYSTEM MAGNETOMETER SYSTEM LONG RANGE SYSTEM IONIC SEARCH SYSTEM 3D IMAGING SYSTEM...
  • Page 3 English User Manual Critical Warning    Please be sure that all precautions taken against risks Overview Do not use your device while it is raining or on extremely wet floor  Dear customer, thank you for Turn on your device after you make choosing the TITAN GER –...
  • Page 4 English User Manual Recipient Antenna Signal Recipient Signal Transmitter Dispatcher Antenna This system specializes to cover vast areas and locate the target with in 1 meter Square up to depths of 5 meters below the surface of the ground and Front Range up to 2,500 meters.
  • Page 5 English User Manual Connect the Signal Transmitter Connect the Signal Recipient Connect the Recipient Antenna...
  • Page 6 English User Manual - Connect the Battery to the Device - Open the Device Screen and Start The Device Through ON / OFF switch CLICK ON THE SCREEN OF THE DEVICE TO DISPLAY THE LANGUAGES LIST THE DEVICE WORKS ON FOUR LANGUAGES: (DUTCH-ENGLISH-FRENCH-ARABIC )
  • Page 7 English User Manual After selecting the language, you want to work in (English for example) The search systems menu will appear (Select long-range search system ) After selecting the long-range system, the metals that this system can detect will appear : Choose the metal to be search for from a list of metals through pressure on the metal name, (BURIED GOLD FOR EXAMPLE)
  • Page 8 English User Manual After selecting the Front Range, the search screen will appear which contain an indicator, which will guide you directly to the target. Make sure that the antenna is pointing ahead Adjust the antenna with the indicator on the screen to receive accurate signal Increase the length of the antennas receiving a signal To able the device to detects targets even to...
  • Page 9 English User Manual Star the search by holding the device as follow: If the target on the right side the indicator Will Point to the right side and the seam to the left side as follow After detecting the target, confirm the target from four direction North to South South to North East to West...
  • Page 10 English User Manual To determine the depth of the discovered target Stand above target and turn 45 degrees Walk straight ahead until the antenna reverse to the back Measure the distance between the antennas reversing back and the target center point. The distance between the antennas reversing back and the center point is equal the target depth For example, if the distance is...
  • Page 11 English User Manual The Ionic Search System Recipient Antenna Dispatcher Antenna This system specializes to cover vast areas and locate the target with meter Square up to a depths of meters below the surface of The ground and Front Range up to 2500 meters vertical Connect component...
  • Page 12 English User Manual Connect the Ionic Sensor - Connect the Battery to the Device - Open the Device Screen and Start the Device through ON / OFF switch Click on the screen of the device to display the languages list the device works on four languages: (DUTCH-ENGLISH-FRENCH-ARABIC)
  • Page 13 English User Manual After selecting the language, you want to work in (English for example) The search systems menu will appear, Select IONIC search system After selecting the ionic system, the search screen will appear. Point the device to the ground if the device start to make a sound you must calibrate The device with the ground by pressing on the calibration button...
  • Page 14 English User Manual After you finish the calibration, start the search by moving the device 180 degrees right and left. When the device detect a target, it will start to make a sound. In addition, the indicter will start to move to alert you about the target discovered.
  • Page 15 English User Manual In the event of lack of vision, you can operate the laser to locate the target place. Through the laser ON OFF, button...
  • Page 16 English User Manual 3D Imaging System Tablet 3D Sensor Tablet Holder Dispatcher Antenna This system specializes to show you the area scanned on the tablet screen in three-dimensional photo and through which you can specify the target size, shape and depth of the target underground up to 45 meters.
  • Page 17 English User Manual Connect the 3D Imaging Sensor Install the Tablet Holder To The Device Fix the tablet that supplied with the device on the tablet holder which Contains analysis program to display the photo...
  • Page 18 English User Manual - Turning to the tablet to make a Bluetooth connection between the device and the analysis program. Click on the Desktop option The desktop screen will appear. 1- Touch the arrow to revel the hidden icons. 2- Click on the Bluetooth icon. 3- Chose add a Bluetooth device...
  • Page 19 English User Manual The tablet will start to search for any devices with Bluetooth in the area. When the device Bluetooth appear click on pair.
  • Page 20 English User Manual NOTE: The Bluetooth password is 1000 select the 3D IMAGING system from the systems menu in the device. After selecting the 3D imaging system, the search screen will appear.
  • Page 21 English User Manual Open the 3D GER Analyzer that installed on the tablet Start a new project to scan the ground by clicking on new scan...
  • Page 22 English User Manual The connection settings window will appear on the screen. Enter the settings as follow 1- CHOSE DEVICE : TITAN GER 2- INTER FACE : OPEN THE BLUETOOTH SETTINGS AND ENTER THE COM NUMBER ( OUT GOING ) FOR EXAMBLE COM 17...
  • Page 23: Transmission Method

    English User Manual 3- TRANSMISSION METHOD : BLUETOOTH 4- OPERATING MODE : GROUND SCAN 5- IMPULSES PER LINE : 10 TO 50 ( EACH IMPULSE = 30 CM ) 6- NUMBER OF LINES : 1 TO 15 ( EACH IMPULSE = 30 CM ) 7- SCAN DIRECTION : OPTIONAL...
  • Page 24 English User Manual After you enter the sittings, click on connect and shift to the device. Therefore, the device will start taking pictures as follow:...
  • Page 25 English User Manual Explaining Start new scan and disconnect after scanning finish Open file from your tablet already existing in your tablet Cancel the scanning or delete the photo Save the photo as a .GER file to re-open it any time you want Save as a photo with no option to change anything in the photo shape To return the photo as it is was before you start analyzing To hide and appear the grid which Represent the number of photo in the scan...
  • Page 26 English User Manual Miniature to make the picture smaller A Tool you use it in case of not clear target to see the correct shape ( - ) A Tool you use it in case of not clear target to see the correct shape ( + ) to make the target in high size to make the target in low size Depth when you can see the target exact depth...
  • Page 27 English User Manual If you want to have printed report you can press on the print icon, the report will appear, and you can print it (the number in the report it is the value of the ground – metals – cavities...
  • Page 28 English User Manual Magnetometer Sensor Connect component Connect the Sensor to the Device...
  • Page 29 English User Manual Click on the screen of the device to display the languages list The device works on four languages: (DUTCH-ENGLISH-FRENCH-ARABIC) After selecting the language, you want to work in (English for example) The search systems menu will appear Select MAGNETOMETER search system...
  • Page 30: Calibration Button

    English User Manual After selecting the magnetometer system, the search screen will appear. Point the device to the ground if the device start to make a sound you must calibrate The device with the ground by pressing on the calibration button follow: After you finish the calibration, start the search by moving the device forward and back agents the ground...
  • Page 31 English User Manual When the device detect a target, it will start to make a sound. In addition, the indicter will start to move to alert you about the target discovered. The sound will start Accelerating when you will be close to the target.
  • Page 32 English User Manual • The Pulse induction System Coil handle Coil This system specializes to cover vast areas and locate the target with in meter Square up to depths of meters below the surface of the ground. Connect component Connect the coil cable to the device Start the device by pressing on the power switch (on off)
  • Page 33 English User Manual After pressıng the on off button Make sure that there is no metal on the person he will hold the device or electronic devices or mobile phones or high voltage electricity wires in the area you want to use the device in open the device by the start button Select the device language from the list of languages Move between languages through the navigation keys...
  • Page 34 English User Manual After selecting the language the device will open to the discrimination search mode First, you have to calibrate the device with the ground when you start searching (during the search if you hear noise you have to make calibration again Hold the device like this...
  • Page 35 English User Manual The device work on two modes 1- Discrimination search mode : This mode can discriminate between ferrous metal and non-ferrous 2- Cavity search mode This mode can detect all cavities under the ground (Natural cavities – made by human cavities) In addition, it can show you the shape and the size Start the search by moving the device right and left in stable movement and close to the ground.
  • Page 36 English User Manual İn case the device detect any metal an indicator will appear on the Start with the normal search mode screen and you will start to hear sound conforming the target present: Non-ferrous Adjust the sensitivity by the navigation buttons UP & DOWN. Switch between the options by start button.
  • Page 37 English User Manual After detecting the target, confirm the target from four direction North to South South to North East to West West to East İn the cavity search mode start your scan in stable way to determine the shape of the cavity. Thanks for choosing our We wish you the best of products...
  • Page 38 English User Manual If you want the device work well without errors you have to follow next steps When using the device please do not wear the watch When using the device please do not wear the jewelry When using the device please get away from metal, lighter and mobile phone Please take off the belt The shoes shoud not contain any metal Stay away from the car...