SMS-Butler-Mobile SMSB-M1-V3 User Manual Manual version 1.0 Free SMS-Butler-Mobile APP...
Page 2
SMS-Butler-Mobile GSM Power Socket Thank you for purchasing the SMS-Butler-Mobile. SMS-Butler-Mobile GSM power socket is a remote-controlled socket consisting of a GSM module. The power supply output can be turned on or off remotely by the SMS command or local controlled by pressing button.
SMS-Butler-Mobile POWER SOCKET USER MANUAL For your safety ......................... 7 Exception clause ........................9 1.1 Package contents ......................10 1.2 Sockets instructions ......................11 1.3 Light indicator ........................14 2.1 User authorization level ....................15 2.2 About the SMS Command ....................16 3.1 Start to use ........................
Page 4
SMS-Butler-Mobile POWER SOCKET USER MANUAL 3.3.1 Register Family-number ....................19 3.3.2 Check Family number ....................19 3.3.3 Delete Family ........................ 19 3.4 Control socket power ....................... 20 3.5 Delay control the socket output ..................20 3.6 Calendar control ......................22 3.6.1 Activate calendar control ....................
Page 5
SMS-Butler-Mobile POWER SOCKET USER MANUAL 3.8 Temperature alarm......................28 3.9 SMS when on/off button pressed..................29 3.10 SMS when power lost or restore..................30 3.11 SMS notification to User ....................30 3.12 Check status ........................31 3.13 Weak GSM signal notification ..................31 3.14 Change password ......................
Page 6
1. Purchase a GSM SIM card (mobile phone card) from GSM network service provider and install it in the socket. This SIM card number is referred as SMS-Butler-Mobile number on this brochure. 2. The user needs to activate the Caller ID Presentation function of SIM card, and deactivate PIN code of the SIM.
SMS-Butler-Mobile POWER SOCKET USER MANUAL For your safety • This socket was designed for home or office use. Do not use it on the electrical appliance which is for industry or business operation, for example, iatrical appliances, large heaters and refrigerates.
Page 8
SMS-Butler-Mobile POWER SOCKET USER MANUAL equipment likely to interfere with the wireless signals, in order to avoid signals interference. • Switch off this socket and mobile phone when entering areas marked "Explosive", "Might explode", "Closed wireless transceiver sockets" etc. •...
2. For the latest socket information, please visit: http://www.elbro.com. We don’t guarantee for the document veracity, reliability or any content except regulate in proper laws. Including no guarantee for socket suitable market or suitable area promise.
SMS-Butler-Mobile POWER SOCKET USER MANUAL 1.3 Light indicator Model Indicator Action Status Turning off Socket power output OFF Power icon indicator Constant light Socket power output ON Searching GSM network Flash slowly SMS-Butler-Mobile Working standby Slowly breath mode. Wireless icon...
There are two mobile phone user controlling levels: Master-user (“Master”): Only one Master has authorization to use all features of SMS-Butler-Mobile. In order to enable all the functions on the socket, the Master must store his/ her mobile number in the socket’s memory. Only one Master’s mobile number is allowed for a socket.
• No allow any space within the commands. 3.1 Start to use • Installed SIM card to SMS-Butler-Mobile GSM power socket: you will see a SIM card slot at the side, make the SIM card metal contact upside and hardly push the SIM card until SIM card fixed.
Page 17
LED means the socket already register GSM network, its ready to work. The socket default power output is OFF. 2. Insert the plug of electronic appliance in the SMS-Butler-Mobile electrical outlet. 3. M button (See 5 on Figure1) can be pressed for about one second to switch on or off the socket output.
SMS-Butler-Mobile POWER SOCKET USER MANUAL user should ensure that socket is used in an area with a strong GSM network signal. • For the first-time use, the user should perform a test-run by sending SMS to the socket. This allows the user to check the GSM network connection of the socket.
SMS-Butler-Mobile POWER SOCKET USER MANUAL 3.3.1 Register Family-number Up to 4 Family-number can be stored on GSM socket. Family-number has the authority to send SMS command to switch on or cut off the socket power output. Method Master sends following SMS message in order to: Register a Family: #06#Family-Number# •...
SMS-Butler-Mobile POWER SOCKET USER MANUAL Delete a Family: #15#Family-Number# Delete all Familes: #15# 3.4 Control socket power Method Method 1:To press M button one second (See 5 on Figure1). Method 2: Master sends following SMS message to socket in order to:...
Page 21
SMS-Butler-Mobile POWER SOCKET USER MANUAL or M button, activate calendar control or thermostat control will also deactivate the delay control function. • When the “delayed switch on the socket” command is received and if the socket output is switched on, the socket output will be switched off immediately and be switch on again as the setting delayed time is reaching.
SMS-Butler-Mobile POWER SOCKET USER MANUAL 3.6 Calendar control 3.6.1 Activate calendar control Description • The socket output can be set to switch on for duration and then be switch off after the duration. • Calendar control function will auto deactivate if user manually change the socket status by SMS or M button, Delay control or Thermostat control will also deactivate calendar control function.
SMS-Butler-Mobile POWER SOCKET USER MANUAL 3.6.2 Set calendar Description After successful setting of time duration to switch on the socket output, the schedule parameter will be saved on the socket until socket reset to factory settings. Method Master sends following SMS message in order to:...
Page 24
SMS-Butler-Mobile POWER SOCKET USER MANUAL • WorkDay: one digit, the values lie in the range of “0” to “8”. The following table contains the descriptions of each value: Value Corresponding day Everyday Monday Tuesday Wednesday Thursday Friday Saturday Sunday Monday to Friday Weekend •...
StartTime bigger than EndTime, it will operate until next day EndTime. • The socket output will switch on at the StartTime and cut off at the EndTime. • For example: #20#0#1#0000#2130# , 0 means the SMS-Butler-Mobile, 0000 means time 00:00(hh:mm)AM, 2130 means time 9:30PM.
SMS-Butler-Mobile POWER SOCKET USER MANUAL 3.7 Thermostat control 3.7.1 Activate thermostat function Description • The external temperature sensor must be inserted into the I/O port of socket. The socket power output can be auto controlled according environment temperature change.
Mode parameter can be 1 or 2, Warming mode is 1, cooling mode is 2; Temp range should be within -10 to 50 degree. For example #24#0#1#15#25#, it means set SMS-Butler-Mobile thermostat control parameter, work with warming mode, and turn on socket when temperature lower than 15 degree, turn off socket when temperature higher than 25 degree.
Description A range of temperature can be pre-set onto socket. In this case, if the surroundings temperature is detected out of the pre-set temperature range, SMS-Butler-Mobile socket will auto-send the SMS alarm message to your mobile phone. This feature depends on the temperature sensor.
Deactivate temperature alarm: #21#0#0# (19) 3.9 SMS when on/off button pressed Description SMS-Butler-Mobile socket will default sending SMS notify Master and Family when on/off button pressed. The Master can enable/disable this SMS notification. Method Master sends following SMS message in order to:...
SMS-Butler-Mobile POWER SOCKET USER MANUAL 3.10 SMS when power lost or restore Description SMS-Butler-Mobile socket will default sending SMS notify when main power supply lost or restore. Master can enable/disable this SMS notification. Method Master sends following SMS message in order to set:...
SMS-Butler-Mobile POWER SOCKET USER MANUAL Master sends following SMS message in order to: Activate SMS alert to User (Default) #16#1# (24) Deactivate SMS alert to User #16#0# (25) 3.12 Check status Method Master or Family sends following SMS message in order to:...
SMS-Butler-Mobile POWER SOCKET USER MANUAL user can enable/disable this SMS notification. Method The Master user sends following SMS message in order to set: Check GSM signal: #27# (31) Activate SMS notification upon weak GSM signal: #27#1# (32) Deactivate SMS notification upon weak GSM signal (Default):...
SMS-Butler-Mobile POWER SOCKET USER MANUAL Change the password: #04#Oldpassword#Newpassword# (34) • The password is a four digit number. • The original password is 1234. 3.15 Resetting the socket Description • This function resets all programmed settings to their original values, including cleaning all user number, timing parameter and temperature parameter.
SMS-Butler-Mobile POWER SOCKET USER MANUAL 4 Main Technical Parameters Input power plug 110 - 230 V/50 Hz, Typ12 Output power outlet 110 - 230 V/50 Hz, 230V, 10A langfristig, Typ 13 Operating temperature -10 °C - +50 °C Store temperature -20 °C - +60 °C...
SMS-Butler-Mobile POWER SOCKET USER MANUAL Appendix: SMS commands list Category Function Command Register Master-number (1) #00# Change Master-number (2) #14#NewMasterNumber# Define the Add Family-number (3) #06#Family-Number# users Check Family-number (4) #06# Delete Family-number (5) #15#Family-Number# Delete all Family-number (6) #15#...
Page 36
SMS-Butler-Mobile POWER SOCKET USER MANUAL Category Function Command Delay switching OFF after a (10) #12#0#Minutes#0# certain minutes Activate calendar control (11) #19#0#1# Calendar Set calendar control (12) #20#0#WorkDay# control parameters StartTime#EndTime# Deactivate calendar control (13) #19#0#0# Activate thermostat control (14) #23#0#1#...
Page 37
SMS-Butler-Mobile POWER SOCKET USER MANUAL Category Function Command SMS when on/off button (20) #03#1# pressed (Default) SMS when on/off button (21) #03#0# pressed function OFF SMS when power lost or (22) #05#1# restore (Default) SMS when power lost or (23 #05#0#...
Page 38
SMS-Butler-Mobile POWER SOCKET USER MANUAL Category Function Command Check “Thermostat control” (29) #32# status Check “temp-alarm” status (30) #35# Check GSM signal (31) #27# Weak GSM signal alert (32) #27#1# Disable weak GSM signal alert (33) #27#0# Change Change password...
Need help?
Do you have a question about the SMS-Butler-Mobile and is the answer not in the manual?
Questions and answers