  • Page 1 READ AND SAVE THESE INSTRUCTIONS P/N 35010041-B user manual...
  • Page 2: Dimensions

    Dimensions All dimensions are in millimeters Dimensions...
  • Page 3 The Martin logo, the RUSH by Martin logo, the RUSH by Martin name, the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries.
  • Page 4: Table Of Contents

    Contents Dimensions ..........................2 Contents ............................. 4 Safety information ........................5 Product overview ........................8 Product description ........................ 8 Features at a glance ....................... 8 Product details ........................9 Quick Start ..........................12 Setting up ..........................12 Making fog and haze ......................12 Installation and setting up ......................
  • Page 5: Safety Information

    Safety information Read the safety precautions in this manual befor installing, operating or servicing this product. The following symbols are used to identify important safety information: Caution! Safety Caution! Burn Danger! Caution! Fire hazard. Risk of hazard. Hot Hazardous hazard. severe injury or surface.
  • Page 6 • This system is not waterproof and should not be exposed to wet outdoor conditions. Do not immerse in water or any other liquid. Do not expose to high-pressure water jets. • Do not spill fluid over or inside the system. If fluid is spilled, disconnect AC power and clean with a damp cloth.
  • Page 7 Do not attempt to use a system that is obviously damaged. • Do not modify the system in any way not described in this manual or install other than genuine RUSH by Martin™ parts. • Refer any service operation not described in this manual to a qualified technician.
  • Page 8: Product Overview

    P r o d u c t d e s c r i p t i o n The RUSH Club Smoke Dual™ is a top of the range atmosphere system from Martin Professional featuring multiple remote fog or haze heads with a base pump/fluid unit.
  • Page 9: Product Details

    P r o d u c t d e t a i l s Fog Head If suspending overhead: Loop safety cable under hanging bracket and secure Control input from pump unit Control link output to next head Mains power switch Mains inlet cable...
  • Page 10 If suspending overhead: Loop safety cable under Haze Head hanging bracket and secure Control input from pump unit Control link output to next head Mains power switch Mains inlet cable Heat (red) and Haze fan inlet Fluid pipe Ready (green) connection indicators Haze output...
  • Page 11 Base pump unit External fluid connection (Top and bottom) AVR program Fluid Control upload socket connections to outputs to and status LEDs heads heads Power inlet connector 3 pin DMX Main power input and switch link Digital remote plug Hinged door to fluid tank compartment 5 pin DMX...
  • Page 12: Quick Start

    Connect the heads to the base unit with RJ45 cables. If you are connecting 2 heads to an output, the second head is linked from the first. Fill the fluid tank in the base unit with RUSH Club Smoke Dual Fluid™ only. Use of other fluid will void the warranty.
  • Page 13: Installation And Setting Up

    “Safety information” on page 5. L o c a t i o n The RUSH Club Smoke Dual™ heads are designed to be located on the floor or may be suspended using the fitted flying bracket. The heads can operate in any orientation from vertically down to vertically up.
  • Page 14: Setting Up

    S e t t i n g u p Fill the fluid tank only with Martin RUSH Club Smoke Dual Fluid™ (see page 25). Up to two heads of the same type (fog or haze) may be connected to each fluid output of the pump unit.
  • Page 15 Connection of two heads on one channel T-connector Connection of fully loaded system Haze heads on channel 1 T-connector Installation and setting up...
  • Page 16: Final Checks

    If DMX control is being used, connect the base unit to the DMX line (see page 18). If the Digital Remote is being used (optional accessory), connect the remote to the Remote socket (see page 9). F i n a l c h e c k s Before applying power to the system, verify the following: •...
  • Page 17: Control Settings

    Control settings O v e r v i e w The digital display on the side of the base unit allows you to configure the system using option menus. Enter/store button Digital display  Menu previous/next Value down/up buttons buttons Quick access buttons PRIME1 PRIME2 PRIME3 PRIME BASE The brightness of the display can be changed to LOW, NORM or HIGH using the...
  • Page 18: Setting Output Density For Haze Heads

    Use the Up/Down buttons to select     . Press the Enter button to store the setting. The display shows . S e t t i n g o u t p u t d e n s i t y f o r H a z e h e a d s Use the Menu Previous / Next buttons to select the ...
  • Page 19: Priming System With Quick Access Buttons

    • To prime the pipework in between the pump units and the heads after installation, use the 4 quick access buttons below the display to prime outputs 1, 2 ,3 or the base independently. See next section. Use the Previous / Next buttons to select the  option. Use the Up/Down buttons to change the option to .
  • Page 20 The factory settings are: option setting FOG  HAZE  TRUN  seconds TOFF seconds RUNF  RUNH  ADDR  DISP  LINK  PRME  Control settings...
  • Page 21: Remote Control

    O v e r v i e w The digital remote control, available separately (P/N 92765043), may be used for remote control of the RUSH Club Smoke Dual™. Several systems may be controlled from one remote using the LINK function (see page 18).
  • Page 22 The remote control is powered through its cable by the RUSH Club Smoke Dual™; no batteries are required. The cable may be extended to up to 25 m (82 ft.) with a 3-pin XLR DMX cable. Remote control...
  • Page 23: Dmx Control

    18. The RUSH Club Smoke Dual™ requires four DMX channels. For example if the RUSH Club Smoke Dual™ is set to DMX address 100, channel 1 will be controlled by address 100, channel 2 will be controlled by address 101, channel 3 by address 102 and channel 4 by address 103.
  • Page 24 Channel 1 DMX value Function Macro description Default range value Fog/haze 0-12 Idle range None output 1 13- 240 Output 0- level 100% 241 -255 Output 100% Channel 2 DMX value Function Macro description Default range value Fog/haze 0-12 Idle range None output 2 13- 240...
  • Page 25: Fog Fluid Types

    Fog fluid types The RUSH Club Smoke Dual™ must only be used with RUSH Club Smoke Dual Fluid™. Martin supplies high quality fog fluids that are based on ultra-pure deionized water. No other fluid is suitable for use. P/N 97120070...
  • Page 26: Basic Service

    Basic service Before servicing the RUSH Club Smoke Dual™, read and observe all the precautions listed in “Safety information” on page 5. Any service not described in this section must be carried out by a Martin service technician. To find your local Martin service centre visit www.martin.com...
  • Page 27: Troubleshooting

    Troubleshooting Problem Probable cause(s) Suggested remedy System not at operating Wait until  message temperature no longer shown System will not produce  or  set to 0 Increase setting fog/haze when control panel set to RUN or remote control ...
  • Page 28: Status Messages

    Status messages message reason The heaters are Off, the unit is shut down.  The unit is heating up to operating temperature.  The heater is at operating temperature, but Fog is not turned  on (RUN set to STBY or FOG set to 0%). The heater is at operating temperature and the unit is under ...
  • Page 29: Specifications

    Fluid pump ............Oscillating piston, high pressure Onboard fluid capacity ............10 litres (2.64 US gal.) Compatible fluids ............RUSH Club Smoke Dual fluid Optional external fluid, top or bottom connection I n s t a l l a t i o n Orientation ..................
  • Page 30 Max distance from pump unit to fog heads ............. 50 m Max distance from pump unit to haze heads ..........10 m Max height difference between pump units and heads ........10 m C o n n e c t i o n s Power connection (base) ..................
  • Page 31 O r d e r i n g i n f o r m a t i o n Pump unit RUSH Club Smoke Dual™ US model 120V ....... P/N 92250140 Pump unit RUSH Club Smoke Dual™ EU model 230V ....... P/N 92250130 Fog head RUSH Club Smoke Dual™...