1. Summary

PM-3000 Digital Pressure Gauge Series are designed for pressure applications that involve
measurement of any media compatible with 316 stainless steel. Designed for battery operation, this
digital gauge has an automatic shutoff feature allowing the user to walk away after taking a
reading .Water-proof housing adopted for harsh environment is our big advantage.

2. Technical Parameters

Wetted parts
Housing
Power supply
Media
Protection grade
Pressure port
Accuracy
Pressure Range(Bar)
Over pressure
4X Full Range or 20kpsi which
Burst pressure
Life
Display

Operating Manual

SS304/ss316
Plastic (water proof)
9V battery
Be compatible with 316L
IP66
G1/2,G1/4 optional
0.5%FS(typical) ,0.25%FS Response
0...600
3X Full Range
is less
7
>10
Full Range Pressure
4 1/2 digit LCD
Operable Temp.(℃)
Storage Temp(℃)
Long term stability
Zero error(%FS)
Full range error( %FS)
Thermal Zero drift(%FS)
Thermal Span drift(%FS)
Life cycle
Insulation
Shock
Noise
Pressure reference
Weight
-20~85℃
-20℃...125℃
±0.25%FS(annual)
±0.5%
±0.5%
±1.0%
±1.0%
9 millions
5ms
Min1MΩ @250VDC&25℃
100g,11msec
< 2m VRMS
Absolute /Vent Gauge
200g Max

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PM-3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for HUA TIAN PM-3000

  • Page 1: Operating Manual

    Operating Manual 1. Summary PM-3000 Digital Pressure Gauge Series are designed for pressure applications that involve measurement of any media compatible with 316 stainless steel. Designed for battery operation, this digital gauge has an automatic shutoff feature allowing the user to walk away after taking a reading .Water-proof housing adopted for harsh environment is our big advantage.
  • Page 2  Increase parameter values or change setting mode in Set Up Mode 5. Installation PM-3000 can be directly mounted in the hydraulic pipe through the pressure pipe joints (M20*1.5) other size fittings available when ordering .In critical applications , such as severe vibration or shock , pressure hose pipe connection can be micro-mechanical decoupling.
  • Page 3 6. Battery Replacement Remove back cover in the direction of arrow of the unit carefully remove battery from the holders by lifting up the positive end of the battery (opposite the spring) .Take care not to bend or distort the battery retention springs.

Table of Contents