l. The UVC filter should be placed somewhere that the water will not submerge it, and it should be at a
2 meters
distance from the edge of the pond to the fitter. This equipment cannot be used under the water.
2.Before the water circulation, the electrical source of the UVC filter cannot be switched on.
3.Please place the UVC in the steady and safe spot, because the UV light tube is made of quartz
glass which
is easy to broken.
4.Before all parts are installed completely, the electrical source cannot switch on.
5.lf the UV light tube or the body shell looks like broken, the equipment cannot be used.
6.When any person in the water, the UVC cannot be used.
7.Please make sure that the electrical voltage, frequency used are consistent with the indication on the
UVC station.
8.When installing the equipment, the installation regulation of domestic should be followed.
9.Pull the connecting cable is forbidden. And please protect the connecting cable from heat, greasi-
ness or
sharpness.
l. Make sure the max pressure of the body shell ensured is less than l.0bar.
ll. When know the frost is coming, please move away UV filter.
l2.When install the UV filter, p|ease not let it under the sunlight directly.
l3.The dirtiness on the quartz tube will influence the effect of the equipment please clean the quartz
tube in time.
l4.In order to ensure the effect of the equipment, the UV light tube should be replaced after 8000hours'
usage.
l5.When the body shell is blocked with the sands rubbish, it may destroy the quartz tube. So please
add the
filter sponge in the inlet of the water pump.
l6.UVC is harmful to the eyes and skin. Please do not watch UVC directly or let the skin approach to
UVC.
l7.When install or repair this equipment, the electrical source of the aquarium must be switched off.
l8.The product must be installed horizontally and with the feet down. Other installation positions are
prohibited
for safety reason.
19.The UVC lamp installed in the unit is intended to kill algae and bacteria in the pond water. Even in
small
doses, its radiation is harmful for eyes and skin.
20.Never use the UVC lamp in a defective housing or outside the housing, or any other purpose other
than
that intended. The following restrictions apply to the unit:
—Never use the unit to convey fluids to other than water. —Never use the unit without water.
—Do not use for commercial or industrial purposes.
INSTRUCTION
1.When the water go through the pump and the device, this equipment emit 253.7 nm ultraviolet ray,
after a short irradiation, most of the bacteria and algae is killed,
provide a healthy environment for the fish.
2.This device does not provide water pump, please buy water
pump.
3.Please connect the inlet pipe with the outlet of the water pump.
4.Please connect the outlet pipe with other filter or the pond.
5.Please check it whether the water started circulation or not after
several minutes, and check the sealing condition of connectors.
6.Turn on electrical source, the UV filter begin to work.
Important: connect the water pump first, and then connect the UV device. Do not run the device
without water. This device will be automatically turned on after the power on.
-When the uv germicidal lamp shows blue light, it means the equipment running normally.