Thank you for purchasing the HAKKO FA-430 Fume Extraction system.
Please read this manual before operating the HAKKO FA-430.
Keep this manual readily accessible for reference.
Please check to make sure that all items
1. PACKING LIST AND PART NAMES
listed below are included in the package.
HAKKO FA-430 Fume extraction system
1
Main filter (inside main unit)
Power cord
Pre-filter
1
             
Cap (inside main unit)
Instruction manual
1
Cap
HAKKO FA-430
Fume extraction
●Duct set (not included)
●Option
Duct set (Duct / Adapter / Rectangular nozzle or
3 inch adapter
Round nozzle / Net)
Duct
Adapter
Bench top hood
Net
Rectangular nozzle
or
Round nozzle
2. SPECIFICATIONS
HAKKO FA-430
120W
Power Consumption
*Specifications and design are subject to
High
  Low
Suction Capacity *1
  Medium
change without notice.
4.7m³/min 3.7m³/min
2.8m³/min
High: 99.96% / Medium·Low: 99.97%
Filtering Efficiency *2
φ55 mm
Duct diameter
330(W) x 366(H) x 343(D) mm
Dimensions
7.5 kg
Weight (w/o cord)
*1 When using 2 ducts
*2 It is an initial value of collection efficiency based on counting method for airborne dust collected
by a single plate of filter (unfolded).
This product includes such features as electrically conductive plastic parts and grounding of the unit
as measures to protect the device to be soldered from the effects of static electricity. Be sure to observe
the following instructions:
1. The plastic parts are not insulators, they are conductors. When making repairs or replacing
parts, take sufficient care not to expose live electrical parts or damage insulation materials.
2. Be sure to ground the unit during use.
Copyright © 2012 HAKKO Corporation. All Rights Reserved.
3.WARNINGS, CAUTIONS, NOTES AND EXAMPLES
Do not absorb combustible, explosive or corrosive gas.
Store the fume extraction unit in a dry place.
Do not block the exhaust vent of the fume extraction unit.
Use only genuine HAKKO replacement parts.
Turn the power off when not in use, or left unattended.
Turn the power off when changing parts or storing the HAKKO FA-430.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible
1
for their safety.
10pcs.
Children should be supervised to ensure that they do not play with the appliance.
1
To prevent accidents or damage to the HAKKO FA-430, be sure to observe the followings:
Pre-filter
Do not operate the fume extraction without the filter; otherwise it may cause the unit to malfunction.
Hold the plug when inserting or removing the cord in/from the outlet.
Do not allow the HAKKO FA-430 to become wet, or use it with wet hands.
While using the HAKKO FA-430, don't do anything which may cause bodily harm or physical damage.
4. OPERATION
Power cord
Set the filter
1. Open the upper cover and then remove the
plastic bag from the main filter.
Main filter
2. Put the main filter on the main unit. Set the
filter with the arrow pointing down
(as shown in the illustration).
*When using the duct for B2410
(φ75 mm) , set the 3 inch
3. Fit the pre-filter on top of the main filter.
adapter to the main unit.
(orange side facing up )
Be sure the pre-filter lies flat and completely
covers the top of the main filter with no gaps.
4. Close the upper cover
Attach the duct
A. How to attach duct set
1. Refer to Figure 1(right), and attach the
nozzle and adapter to the duct.
Insert the nozzle and adapter until it stops,
turn the nozzle clockwise. Make sure the
nozzle and adapter are firmly attached.
Twist the nozzle tight enough to avoid
coming off.
2. Fit the net on the nozzle. (Figure.2)
(Fig.2)
3. Insert the duct into the open port.
If using one duct, ensure the cap is in place
on the unused port.
When using two ducts, please store the cap
inside the main unit next to the main filter as
shown in Figure 3 (right).
2012.3
MA01866XZ120301
WARNING
CAUTION
Pre-filter
(orange side
facing up)
Main filter
(facing the
arrow
downward)
(Fig.1)
Be sure the duct is
facing in the
proper direction
during assembly.
1 Insert the nozzle
until it stops.
2
Turn the nozzle clockwise.
or
(Fig.3)
Cap
4. OPERATION
B. How to attach bench top hood.
When using a bench top hood,
the following parts are required:
●3 inch adapter
●3 inch duct (φ75 )
●Duct band
*Refer to "7. PARTS LIST" for part numbers.
*The standard duct for the HAKKO FA-430
can not be used to connect a bench top hood.
3 inch
adapter
Fume extraction unit
Replacement Indicator Lamp
1. Connect the power cord to the power
(Pre-filter/ orange)
receptacle on the right of the unit.
2. Plug the power cord into a ground wall socket.
3. Turn the power switch on. Power lamp will light up.
Close the cover before turning the power switch on.
Low
4. Adjust the flow suitable for working environment
by using flow selection switch.
5. Adjust the angle of the duct and nozzle as needed
for optimal performance.
Filter life reset
Do not block the open port on purpose.
When the fan is running, do not open the
upper cover.
Turn the power off when not in use.
Failure to do so may result in shorter filter life.
If it passes more than 2500 hours or one year
since the HAKKO FA-430 is used, replace the
main filter with new one at once.
If using the main filter over replacement
timing, doing so may result in damage to
the main unit.
Instruction manual in the language of Japanese, English, Chinse, French, German and Korean
can be downloaded from the HAKKO Document Portal.
(Please note that some languages may not be available depending on the product.)
風扇組合
插頭
Duct band
3 inch
duct
Replacement Indicator Lamp
(Main filter/ red)
Power lamp (Green)
Power switch
Medium
High
Flow selection
switch
Exhaust vent

Advertisement

loading

Summary of Contents for HAKO FA-430

  • Page 1 Do not allow the HAKKO FA-430 to become wet, or use it with wet hands. ● Fume extraction unit While using the HAKKO FA-430, don’t do anything which may cause bodily harm or physical damage. ● ● Replacement Indicator Lamp Replacement Indicator Lamp 1.
  • Page 2 ●HAKKO FA-430 is turned on. Apply the following service procedure as dictated by the conditions of the usage. Connect it. HAKKO FA-430 counts used number of the pre-filter in order to determine the Item No. Part No. Part Name Specifications Is the main filter set properly ? remaining life of the main filter.