Blancett B2800 SERIES User Manual

Flow monitor panel mount standard

Advertisement

Quick Links

Flow Monitor
B2800 Panel Mount Standard
User Manual
DSY-PM-00278-EN-03 (March 2017)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B2800 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Blancett B2800 SERIES

  • Page 1 Flow Monitor B2800 Panel Mount Standard User Manual DSY-PM-00278-EN-03 (March 2017)
  • Page 2: Table Of Contents

    Flow Monitor, B2800 Panel Mount Standard CONTENTS Scope of This Manual Unpacking and Inspection Safety Terminology and Symbols Considerations Introduction Installation Operating The Monitor Buttons Modes Programming Programming Mode Run Mode Additional Scaling Parameters Flow 4 mA Setting Flow 20 mA Setting 4…20 mA Calibration 4…20 mA Test Battery Replacement...
  • Page 3: Scope Of This Manual

    Scope of This Manual SCOPE OF THIS MANUAL This manual is intended to help you get the B2800 flow monitor up and running quickly MPOOTANT Read this manual carefully before attempting any installation or operation. Keep the manual accessible for future reference. UNPACKING AND INSPECTION Upon opening the shipping container, visually inspect the product and applicable accessories for any physical damage such as scratches, loose or broken parts, or any other sign of damage that may have occurred during shipment...
  • Page 4: Introduction

    The B2800 flow monitor is a state-of-the-art digital signal processing flow monitor, designed to provide exceptional flexibility at an affordable price Though it is designed for use with Blancett flow meters, this display can be used with almost any flow...
  • Page 5: Operating The Monitor

    OPEOATING THE MONITOO Rate / Total Display Mode Indicator Programming Choices 8635 Washington Avenue ® Racine, WI 53406 Phone: 800-235-1638 Fax: 262-417-1155 Flow Meters www.Blancett.com PROGRAM RELAY1 RELAY2 MENU ENTER Programming Units Display Keys Programming Choices Figure 3: B2800 panel mount flow monitor...
  • Page 6: Programming

    Press ENTEO to save the K-factor unit and advance to the K FACTOR parameter OTEE: Unless otherwise specified, Blancett turbine flow meters are supplied with K-factors measured in pulses per gallon (PUL/GAL) which will automatically convert to your desired units of measure...
  • Page 7: Run Mode

    Programming Select the Units of Measure The monitor is programmed with five common rate/total unit options The monitor shows the rate/total unit that the display is currently set for If the current selection is correct, press ENTEO once to advance to the DISPLAY FUNCTION parameter To change the unit, press UP or OIGHT to scroll to the correct rate unit Press ENTEO to save and advance to the DISPLAY FUNCTION parameter Selection...
  • Page 8: Additional Scaling Parameters

    Additional Scaling Parameters ADDITIONAL SCALING PAOAMETEOS OTEE: The programming instructions below are only available for loop powered units Battery powered units do not include these programming parameters Flow 4 mA Setting Zero is the default flow rate at the 4 mA setting If the current selection is correct, press ENTEO to advance to the Flow 20 mA parameter To change the setting, press UP to increment the flashing digit and press OIGHT to move to the next digit Press ENTEO to save and advance to the Flow 20 mA parameter Flow 20 mA Setting...
  • Page 9: Battery Replacement

    The B2800 flow monitor is capable of receiving magnetic pickup input (small signal sine wave) or a contact closure input (pulse) Since most Blancett turbine flow meters utilize a magnetic pickup, the B2800 flow monitor is shipped configured for magnetic pickup input To change to a contact closure input, remove JP2 from the bottom two pins and jumper them to the...
  • Page 10: Specifications

    Specifications SPECIFICATIONS Power Supply Options Battery Powered One D size, 1 5V alkaline battery Loop Powered Optional 4…20 mA loop power Alphanumeric Oate and Total Display Eight digit, 0 50 inch high numeric display Eight character, 0 25 inch high alphanumeric display Fixed or toggle modes of operation for flow rate and totalizer display Accuracy ±0 1%...
  • Page 11: Dimensions

    Dimensions DIMENSIONS 4 25 in (107 9 mm) 4 25 in (107 9 mm) 0 75 in (19 0 mm) 2 50 in (63 5 mm) 4 54 in (115 3 mm) TOOUBLESHOOTING GUIDE Issue Oemedy No LCD display • Check battery voltage Should be 1 5V DC Replace if low or bad •...
  • Page 12: Default K-Factor Values

    Control. Manage. Optimize. BLANCETT is a registered trademark of Badger Meter, Inc Other trademarks appearing in this document are the property of their respective entities Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists ©...