Download Print this page

Fell Marine MOB Plus xHUB User Manual

Wireless man overboard system

Advertisement

Quick Links

REV200-0318
Thank you for choosing MOB+!
If this is the first time you use the MOB+, visit
www.fellmarine.com/explore
To see install videos, demos, FAQs, online user manual
and other support material, visit:
www.fellmarine.com/support
WIRELESS MOB DETECTION
AUTO ENGINE STOP
LEARN MORE AT: WWW.FELLMARINE.COM
WARNING
Disconnect battery cables at battery before attempting to install
this product
Read all instructions carefully before use of this product.
FELL Marine equipment and accessories are designed to
the best industry standards for use in the recreational marine
environment. Their design and manufacture conforms to the
appropriate Electromagnetic Compatibility (EMC) regulations, but
correct installation is required to ensure that performance is not
compromised. Please see section EMC Installation Guidelines in the
User Manual for optimum EMC conditions.
CAUTION
Within the wireless range MOB+ will not shut down the engine
automatically e.g. if you fall in your boat within the wireless range the
engine will not stop automatically. In this event, you can shut down
the engine by pressing the button on your MOB+ xFOB or on the
MOB+ xHUB. Always check your wireless range before use.
IMPORTANT INFORMATION
The xFOB is waterproof down to 10 ft./3m and can be reused after
MOB event. After an MOB-event, the engine can easily be restarted
by;
dStart - 6 seconds after a MOB Event the system lets
passenger restart the engine to pick up the missing person in
the water. The engine can be started without reconnecting the
xFOB. No interaction with xHUB necessary.
Reconnect with the xFOB by clicking once on the xFOB to
deactivate dStart and once more to connect.
MARCH 2018
REV200-0318
FELL Technology AS
Designs, manuals and features subject
to change. For more information visit our
website: www.fellmarine.com
MAN OVER BOARD
EMC GUIDELINES
The guidelines given here describe the conditions
for optimum EMC performance, but it is recognized that it may
not be possible to meet all of these conditions in all situations. To
ensure the best possible conditions for EMC performance within the
constraints imposed by any location, always ensure the maximum
separation possible between different items of electrical equipment.
For optimum EMC performance, it is recommended that wherever
possible:
FELL equipment and the cables connected to it are:
At least 3 ft. (1 m) from any equipment transmitting or cables
carrying radio signals e.g. VHF radios, cables and antennas.
In the case of SSB radios, the distance should be increased to
7 ft. (2 m).
More than 7 ft. (2 m) from the path of a radar beam. A radar
beam can normally be assumed to spread 20 degrees above
and below the radiating element.
If possible the product is supplied from a separate battery
from that used for engine start. Power supply voltages below
the minimum specified 7V power source, and starter motor
transients, can cause the product to reset. This will not damage
the product, but may cause inability to start the engine.
FELL specified cables are used. Cutting and rejoining these
cables can compromise EMC performance and must be
avoided unless doing so is detailed in the installation manual.
MAN OVER BOARD
MOB Mode (Man Overboard Mode) is the safety mode of the
MOBP17001
system. MOB+ will automatically activate shut down of the engine
when the STOP FOB is submersed in 4 inches (10 cm) of water or
travels out of range from the xHUB. After 6 seconds, the system
automatically activates Override Mode. In Override Mode any
passenger or crew on board can restart the engine without the need
to interact with the MOB+ system. This allows for a quick recovery of
the missing person in the water and enhances safety.
ALARM FUNCTION: If any of the ALARM FOBs falls overboard
the xHUB will NOT stop the engine(s), but sound the MOB Alarm,
flashing on the xFOB Connection Indicator on the xHUB and blink
red in the light circle. The alarm continues until the STOP button on
the xHUB is pushed to disengage the alarm.
MOB EVENT RECONNECT: In an MOB event where the STOP FOB
falls overboard, the person returning from the water can reconnect
the xFOB by one click to disable MOB Mode, followed by one more
click on the xFOB to reconnect. Alternatively, remaining passengers
with an ALARM FOB can choose to connect one of their xFOBs.
OVERRIDE MODE
In the event that you forget your xFOB or if
it´s out of battery - don´t worry. You can easily
override MOB+ by holding the button on the
xHUB for 10 seconds. The xHUB will give a
sound signal and a yellow light signal every 30
seconds to indicate Override Mode is activated
so you can start the engine(s).
dStart
dStart is the direct restart feature in the
MOB+ system. 6 seconds after an MOB event
with a STOP FOB, the MOB+ automatically
activates Override Mode to allow any remaining
passengers in the boat to restart the engine(s)
directly, without interacting with the system.
The Override Mode flashes yellow and gives a
sound feedback every 30 seconds.
© FELL Technology AS
MOBP17003
MOBP17004
MOBP17005
Page 1/9

Advertisement

loading

Summary of Contents for Fell Marine MOB Plus xHUB

  • Page 1 MOB Mode, followed by one more FELL Marine equipment and accessories are designed to click on the xFOB to reconnect. Alternatively, remaining passengers with an ALARM FOB can choose to connect one of their xFOBs.
  • Page 2 Should the signal be noticeably worse, we recommend MOBP17006 using an external antenna to put on the top side of the helm, supplied from FELL Marine. MAN OVER BOARD SEQUENCE • Can passengers start the boat if I were to fall over board? -Yes, this is one of the main features of MOB+.
  • Page 3: Installation

    GENERAL USE AND INSTALLATION SECTION INSTALLATION xFOB INITIAL PAIRING MOBP17010 MOBP17011 After proper installation, pair the xFOB and the xHUB as The installation is simple and below you will described below. The xHUB remembers the 20 last paired find a quick guide. See next page for wiring xFOBs.
  • Page 4 GENERAL USE AND INSTALLATION SECTION VERIFY INSTALLATION CONNECTION OF xFOBS MOBP17012 MOBP17027 The MOB+ allows for the pilot to be connected with his xFOB as a STOP FOB and three more crew members or passengers After installation, test the system as described below to to be connected as ALARM FOBs.
  • Page 5 GENERAL USE AND INSTALLATION SECTION CONNECTING MULTIPLE FOBS WITH STOP FUNCTION MOBP17028 How to connect any of the ALARM FOBs with STOP function. In the event that one (or more) of the ALARM FOBs with STOP function goes overboard, it will trigger automatic engine shut down.
  • Page 6 WIRING SECTION CONNECTING KILL SWITCH SIGNAL WIRES KEEP EXISTING OR MULTIPLE KILL SWITCH MOBP17016 MOB+ xHUB has three kill switch signal wires. Only two of the three Install the MOB+ inline with your existing kill switch or inline with wires should be used. Connect the two signal wires to the existing kill multiple kill switches by connecting it in parallel (e.g.
  • Page 7 P/N: (F-A/N): 72.380.401 This product is designed to be used in conjunction with the MOB+ xHUB to stop Availability: FELL Marine dealers and buy.fellmarine.com multiple engines simultaneously for multiple outboard installations. The MOB+ xHUB should be installed prior to installation of this Multiple Engine Harness.
  • Page 8: Emc Installation Guidelines

    Never overload the boat and be sure to wear your FELL Marine equipment and accessories are designed to the best industry standards for use in life jacket at all times. Check your boat for all required safety equipment and never operate a the recreational marine environment.
  • Page 9 Other safety Considerations Limited Warranty Small parts contained in your device and its accessories may present a choking hazard to small This FELL product is warranted to be free from defects in materials or workmanship for two years children. Personal medical devices, such as pacemakers, may be sensitive to magnetic and from the date of purchase.