Section 3. Troubleshooting
Troubleshooting
Problem
Probable cause(s)
No response from
fixture when power
No power to fixture
is applies
Controller not
connected
Incorrect
addressing of the
fixtures
Bad data link
Fixture resets but
connection
does not respond
Conflict between
correctly to
tracking and vector
controller(DMX
control
mode operation)
Data link not
terminated
Defective fixture or
2 devices
transmitting on link
Colors cannot be
Random color
mixed
mixing is on
Fixture does not
Electronic or
reset correctly
mechanical failure
Remedy
Check power cables
Connect controller
Check address setting on fixture and controller
Inspect cables and correct poor connections
and/or broken cables.
Eliminate scene cross-fade on controller
Insert termination plug in output of last fixture
Bypass fixtures one at a time until normal
operation is regained:unplug both connectors
and connect them directly together
Turn off random color mixing
Contact service technician
7
Section 4. Reference
Control Menu
DMX protocol
Specifications
Control Menu
addr : DMX
chnd : DMX
25 preset colors
colo:
address value
channel model
red:
Red dimmer
gree:
Green dimmer
blue:
Blue dimmer
8