TROUBLESHOOTING GUIDE
SYMPTOM
CAUSE
The pump does not run
Power is not turned on
Incorrectly plugged in
Bound impeller
The motor repeats ON/OFF
Wrong voltage
without running pump. It stops
The water intake or outlet pipe
and does not restart
is clogged with foreign matter
The pump runs with reduced or
Wrong frequency
no performance
Impeller worn out
Low water level
The pump runs normally at the
Hose is too long or clogged
beginning but the water flows
Air in the impeller chamber
sluggishly or there is no water
LIMITED WARRANTY
Your Active Aqua Pump is guaranteed to work for one year from the
date of retail purchase. Replaceable filter material not included. Save
your retail receipt/invoice, a copy is required for all warranty work.
Any alterations to a pump or cord will void warranty. Contact the place
of purchase for repair or replacement. Active Aqua Pumps are sold and
serviced only through dealers.
AASubPump_Instr.11
SOLUTION
Turn on the power
Plug in correctly
Remove foreign matter from impeller
Correct voltage
Clean out the intake and outlet
Correct frequency
Replace impeller
Ensure the pump is fully submerged
Shorten hose and/or clean out
To get rid of air, put pump into the
water. Turn the switch to "ON" and "OFF"
intermittently to clear air from pump
INSTRUCTION MANUAL
ACTIVE AQUA
SUBMERSIBLE PUMP
FOR MODELS: AAPW40, AAPW160, AAPW250,
AAPW400, AAPW550, AAPW800, AAPW1000
Active Aqua Pumps
from Hydrofarm are carefully inspected and
tested to ensure both safety and operating performance. However,
failure to follow the instructions and warnings in this manual may
result in pump damage and/or serious injury. Be sure to read and
save this manual for future reference.
AAPW800/550
AAPW160
AAPW1000
AAPW250/400
AAPW40

Advertisement

loading
Need help?

Need help?

Do you have a question about the AAPW40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ActiveAqua AAPW40

  • Page 1 The pump does not run  Power is not turned on  Turn on the power Incorrectly plugged in Plug in correctly FOR MODELS: AAPW40, AAPW160, AAPW250, Bound impeller Remove foreign matter from impeller AAPW400, AAPW550, AAPW800, AAPW1000   The motor repeats ON/OFF...
  • Page 2 • Do not allow the pump to freeze in winter, remove pump from fountains and ponds AAPW400 and store in a frost-free area. AAPW250 AAPW160 CAUTION AAPW40 Always disconnect from electrical outlet before handling the pump. 1000 1200 Do not let the pump run dry. Do not lift the pump by the power cord.
  • Page 3 Intake screen prevent water from running down the cord into the electrical outlet. Suction cups foam AERATION KIT EDGE OF TANK AAPW40 NTAKE INSTRUCTIONS: The Venturi intake provides air induction when MUFFLER Water outlet the airline is connected to the small...
  • Page 4 AAPW250, AAPW400, AAPW550, AAPW800, AAPW1000 Tube fittings Back cover Outlet O ring Shaft Intake screen foam Motor bushing Impeller cover Flow control Front cover knob Impeller O ring Suction cups Fitting for inline function www.hydrofarm.com...