3i BSE-150 Installation Manual

Active indoor and outdoor infrared barrier with 3 beams of protection

Advertisement

Quick Links

BSE-150
ACTIVE INDOOR AND OUTDOOR
ACTIVE INDOOR AND OUTDOOR
ACTIVE INDOOR AND OUTDOOR
INFRARED BARRIER WITH
INFRARED BARRIER WITH
INFRARED BARRIER WITH
3 BEAMS OF PROTECTION
3 BEAMS OF PROTECTION
3 BEAMS OF PROTECTION
INSTALLATION
INSTALLATION
INSTALLATION
Instruction Manual BSE-150
ENGLISH
MANUAL
MANUAL
MANUAL
Pag. 1

Advertisement

Table of Contents
loading

Summary of Contents for 3i BSE-150

  • Page 1 ACTIVE INDOOR AND OUTDOOR ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH INFRARED BARRIER WITH INFRARED BARRIER WITH 3 BEAMS OF PROTECTION 3 BEAMS OF PROTECTION 3 BEAMS OF PROTECTION INSTALLATION INSTALLATION MANUAL MANUAL INSTALLATION MANUAL Instruction Manual BSE-150 Pag. 1...
  • Page 2: Product Discription

    ENGLISH 1 - Product Discription The BSE-150 is an active indoor & outdoor infrared detector with 3 beams of protection. It has regulations for : Vertical axial from (+10° to –10°), Horizontal axial from (+90° to –90°), and for the trigger response time from 1 to 5 (See Par. 5).
  • Page 3: Installation Precautions

    Avoid mounting the unit in direct sun light or high luminosity light sources. Avoid that a receiver can, by error, receive the signal transmitted form the the wrong unit. See below: Trasmitter Trasmitter Receiver Receiver Trasmitter Receiver ERROR CORRECT Trasmitter Receiver Instruction Manual BSE-150 Pag. 3...
  • Page 4: Installation Procedure

    3.1.4 Fix to the wall the metal base of the sensor. 3.2.4 See below how to fix 2 units to the same column. 3.1.5 Connect the cable to the desire terminal blocks See fig. page 2 for terminal conn. Pag. 4 Manuale istruzioni BSE-150...
  • Page 5 Vertical regulation Riceiver screw. High Left Right Replace the front cover and test if the active infrared barrier is functio- horizontal ning correctly. If not,it must be regulation, rotate the recalibrated. lens body as desired. Instruction Manual BSE-150 Pag. 5...
  • Page 6 Verify the effects on the barrier based on the selected walk. If you are not satisfied with the results, change this regulation until you obtain the best possible results. 6 - Dimension Material for fixing to support column 95mm 89mm Fixing holes 4,5mm Support Column 55 mm Pag. 6 Manuale istruzioni BSE-150...
  • Page 7: In Case Of Problems

    SENSOR MATERIAL....WEIGHT......Trasmitter 630 g - Riceiver 660 g Instruction Manual BSE-150 Pag. 7...
  • Page 8 For any problems contact the nearest authorized Tre i Systems sales office or service center. Tre i Systems reserves the right to change or make improvments to this product without previous notice. Last revision 07-02-2013 Pag. 8 Manuale istruzioni BSE-150...