Download Print this page

CANUSA-CPS 99060-262 Product Description

Hbe atomizer & cartridge system

Advertisement

Quick Links

HBE Atomizer
& Cartridge System
For spraying HBE 3:1 (1000 mL) and Liquid Epoxy Types 4:1 (940 mL)
Product Description
1
Option A
Canusa Atomizer Gun
HBE Atomizer Cartridge 3:1 (1000mL)
Atomizer Mixing Tip
4
Wipe clean with a lint-free cloth or
air blast the steel and pipe coating to
remove foreign contaminants. Surface
must be clean and dry prior to applica-
tion of HBE products.
INSTALLATION GUIDE
Option B
Canusa Atomizer Gun
Liquid Epoxy Type Atomizer Cartridge 4:1
(940mL)
Atomizer Mixing Tip
Ejector Plate Setup
5
Make sure the correct ejector plate
is mounted on the top piston of the
Atomizer Gun. Option A requires the 3:1
mount plate and Option B requires the
4:1 mount plate. (Mount plates, screws
and alan key included with Atomizer
Gun.)
Surface Preparation
2
Clean exposed steel and adjacent
pipe
coating
according
to
SSPC
SP 1 to remove the presence of oil,
grease, and other contaminants. Ensure
that the pipe is at least 3°C (5°F) above
the dew point before cleaning.
Attach Air Supply
6
Install air inlet fi tting to the atomizer gun
air inlet 1/4" female thread. Attach the
air supply line to the Atomizer inlet fi t-
ting. The air supply pressure should be
100 psi (7 bar) and air fl ow rate shall be
minimum 12 CFM. Only clean and dry air
should be used.
3
SIS Sa 2½
SSPC SP 10
Thoroughly clean the cutback area
to "near white metal" SIS Sa 2½
(SSPC-SP10) or equivalent. Materials
used for abrasive blasting shall produce
an angular surface profi le of 2.5-5 mils
(64-127 μm) Lightly abrade at least
50mm (2") of the line coating on each
side of cutback area.
Atomizer Cartridge Heating
7
Heat the cartridge by means of
microwave
oven,
convention
oven,
electrical hot-box etc. to a conditioned
temperature of 60°C (140°F).
If using a microwave, a rotating 700 watt
microwave is recommended. Presuming
the starting temperature of the cartridge
is 25°C (77°F), heat the cartridge for 1:00
minute on both sides of the cartridge for
a total heating duration of 2:00 minutes.
Use an infrared temperature gun to
check the cartridge (in multiple locations
– top, middle, bottom) to ensure the Base
side is 50-57°C (122-135°F).
canusacps.com

Advertisement

loading

Summary of Contents for CANUSA-CPS 99060-262

  • Page 1 HBE Atomizer & Cartridge System For spraying HBE 3:1 (1000 mL) and Liquid Epoxy Types 4:1 (940 mL) Product Description Surface Preparation SIS Sa 2½ SSPC SP 10 Option A Option B Canusa Atomizer Gun Canusa Atomizer Gun Clean exposed steel and adjacent Thoroughly clean the cutback area pipe coating...
  • Page 2 All information contained in this installation guide is to be used as a guide and is subject to change without notice. This installation guide supersedes all previous installation guides on this product. E&OE Part No. 99060-262 IG_Atomizer_rev015...