Opening Additional Cable Glands; Checking Connections; Switching On The Device; Switching Off The Device - Ebmpapst S4D630-AR01-01 Operating Instructions Manual

Table of Contents

Advertisement

S4D630-AR01-01

4.5 Opening additional cable glands

A second cable gland opening can be made in the terminal box.
WARNING
In the event of a fault, the cable gland is energized
Electric shock
→ Do not use metal cable glands with plastic terminal boxes.
; Screw the cable gland into the precut thread using a wrench. When
doing so, take note of the tightening torques; see Chapter 3.1 Product
drawing.
; Remove the plastic tab that fell off inside the terminal box when it was
penetrated.
Fig. 4: Cable gland opening
NOTE
Tightness and strain relief are dependent on the cable
used.
→ This must be checked by the user.

4.6 Checking connections

; Ensure isolation from supply (all phases).
; Make sure a restart is impossible
; Check the cables for proper fit.
; Screw the terminal box cover back on again. Terminal box tightening
torque, see Chapter 3.1 Product drawing.
; Make sure the terminal box is completely closed and sealed and that
all screws and cable glands have been properly tightened.

4.7 Switching on the device

The device may only be switched on if it has been installed properly and
in accordance with its intended use, including the required safety
mechanisms and professional electrical hookup. This also applies for
devices which have already been equipped with plugs and terminals or
similar connectors by the customer.
WARNING
Hot motor housing
Risk of fire
→ Ensure that no combustible or flammable materials are
located close to the fan.
; Before switching on, check the device for visible external damage
and make sure the protective devices are functional.
; Check the fan's air flow paths for foreign matter and remove any
foreign matter found.
; Apply the nominal supply voltage.
Item no. 10103-5-9970 · ENU · Change 89187 · Approved 2016-04-15 · Page 10 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions

4.8 Switching off the device

; Disconnect the device from the power supply at the supply line's
main switch.
; When disconnecting, be sure to disconnect the ground connection last.
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
Do not perform any repairs on your device. Send the device to ebm-
papst for repair or replacement.
Malfunction/fault
Impeller not
running smoothly
Motor not turning
Motor
overtemperature
WARNING
Live terminals and connections even with device
switched off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
before opening the device.
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Risk of injury
→ Keep out of the device's danger zone.
→ When working on the device, switch off the line voltage
and ensure that it cannot be switched back on.
→ Wait until the device comes to a stop.
→ Install the externally wired thermal overload protector in
the control circuit so that following a malfunction the motor
does not switch on again automatically after cooling off.
If the device is out of use for some time, e.g. when in storage,
we recommend switching it on for at least two hours to allow
any condensation to evaporate and to move the bearings.
Possible cause
Imbalance in rotating
parts
Mechanical blockage
Line voltage faulty
Faulty connection
Thermal overload
protector activated
Impermissible point of
operation
Ambient temperature
too high
Possible remedy
Clean the device;
replace it if imbalance
persists after cleaning.
Make sure no
weight clips are
removed during
cleaning.
Switch off, isolate
from supply and
remove mechanical
blockage.
Check line voltage,
restore power supply.
Isolate from supply,
correct connection;
see connection
diagram.
Allow motor to cool
off, locate and rectify
cause of error,
release restart lockout
if necessary
Check point of
operation
Reduce ambient
temperature if possible

Advertisement

Table of Contents
loading

Table of Contents