Download Print this page

Magnum MN-101 Quick Reference Manual

Hand control unit

Advertisement

Quick Links

Power Button (On/Off) & LED
6x 1/4" Threads
Green = Battery Good
for attaching of additional
Flashing = Battery Low - change battery
accessories.
Unit switches off automatically, when
Caution:
battery power becomes too low
Maximum length of screw
turned into the thread is
<= 8 mm (5/16")!
.
Menu Navigation
Press Center button to
enter the Setup Menu
4 User assignable Keys
(U1 .. U4)
Currently fixed to spread the
wheel scale
Light socket
Only for original scale
illumination LED light!
Battery
7.2V SONY FM-50/55
Chrosziel GmbH, Klausnerring 6, 85551 Heimstetten, Germany, Phone +49 89 901 091 0, Fax +49 89 447 0861,
Quick Reference Guide
Relates To Firmware Version 01.07.xx
MN-101
Hand Control Unit
Camera Record
Area of built-in GHz Antenna
Start/Stop
Do not cover- keep clear!
LED flashes = Record is on
Hand wheel with fixed Fluid
Drag
Accepts 2 different types of scales:
USB Socket for Software
Updates
and hand unit)
Software updates are provided by
Chrosziel, when available.
Update Procedure:
 Copy the two provided software
files into the root of an USB stick
(FAT/FAT32 formatted)
 Power down the handset
 Plug USB stick into socket.
 Press and hold down "REC"
button and power on the handset.
 Unit will perform the update
indicating
Battery Release
different LED flashing patterns on
Slide to the right to change battery
the front. After update the unit
Type
restarts automatically
V2.12
Motor Control Unit
Cam Start/Stop
Type: Lemo ECB.0B.309
Pin 8: CAM Relay 1
Pin 9: CAM Relay 2
Power LED
Green = Power Good (>12V)
Red = Input voltage low
Flashing = voltage drop occurred
Big Ring
Small Ring (as shown in photo)
Area of Built-in GHz Antenna
Do not cover- keep clear!
Rf Error LED
Rf Error LED goes on if no
connection to at least one
hand
unit
could
established.
Choose same channel in the
(always update both MCU
Set Up menu of the hand
unit.
USB Socket for Software Updates and USB Status LED
(always update both MCU and hand unit)
Software updates are provided by Chrosziel, when available .
Update Procedure:
 Copy the two software files into the root of an USB stick (FAT/FAT32
formatted)
 Plug USB stick into socket.
 Power down the unit
the
progress
by
 Press and hold down "Motor Cal" button and repower the receiver.
 Unit will perform the update indicating the progress by different LED blinking
patterns on the front. After update the Unit restarts automatically
info@chrosziel.de;
http://www.chrosziel.de
Power In (10V -30V; with
electronic
Fuse
&
reverse
protection) & Cam Start/Stop
Type: Lemo 0B.305
Pin 1: Battery plus
Pin 2: CAM Relay contact 1
Pin 3: CAM Relay contact 2
Pin 4: Battery minus / GND
Radio Channel Selector + Rf Error LED
Select radio channel within the 2.4 GHz Band
(select 5 .. F). Red LED goes on if connection
be
error occurs. Channels 0..4 not valid! If chosen,
LED is flashing.
Motor Socket
Type: Lemo EGG. 1B. 307
Pin 1: Motor –
Pin 2: Motor +
Pin 3: Encoder channel A
Pin 4: +5V
Pin 5: earth/ground
Pin 6: Encoder channel B
Pin 7: Sense
Motor Status Red LEDs
Signaling
Slow blinking = motor limits
need to be calibrated
Fast
flashing
=
motor
calibration in progress
Off with motor connected =
motor limits are calibrated,
ready to shoot
Cam
Start/Stop
indicator
LED
blue
=
relay
switches
active/connected
off
=
relay
switches
inactive/disconnected
Automatic adjustment of lens-scale
limits and motor-test of connected
digital motor:
This adjustment has to be made whenever
motor and/or lens are changed.
Do not block or stop the lens while end stops
are checked, all parameters will then be
stored incorrectly!
Procedure:
• engage motor onto lens (not at an
end stop)
• Push "Motor Cal." button, red LEDs flash
• Motor starts turning slowly
The lens-scale limit will be checked and
stored automatically.

Advertisement

loading

Summary of Contents for Magnum MN-101

  • Page 1 Quick Reference Guide V2.12 Relates To Firmware Version 01.07.xx MN-101 Hand Control Unit Motor Control Unit Power Button (On/Off) & LED 6x 1/4" Threads Camera Record Area of built-in GHz Antenna Cam Start/Stop Power In (10V -30V; with Motor Socket...
  • Page 2 Spreading is done by pressing one of the user keys 1 .. 4. Spreading function needs to be assigned to the desired user keys*. Default mode Therefore it is not possible to calibrate so-called photo lenses by the motor controller automatically. The MagNum motor controller addresses is: U1-4 spread the wheel scale.