DANGER
• Never judge the measurement results yourself (or do such things as
Never use this product with the following
medical electronic devices.
evaluate measurements or base an exercise plan on this).
(1) Pacemakers and other implantable
• Weight loss and therapeutic exercise based on self-judgment may be
medical electronic devices
bad for your health. Always follow the instructions of a certified
(2) Heart-lung machines and other artificial
professional.
life-support medical electronic devices
• Do not step on the edge of the analyser, jump on the analyser, or
(3) Electrocardiographs and other
jump up and down on the analyser. Doing so may cause you to fall or
wearable medical electronic devices
slip, resulting in serious injury.
This analyser passes a weak electric current
• Do not use the analyser on a slippery surface, such as a tile surface
through the body and may cause the
or wet floor.
above-mentioned devices to malfunction,
Doing so may cause you to fall or slip, resulting in serious injury.
resulting in an accident or serious injury.
Furthermore, water may get inside the analyser and cause a breakdown.
• Never modify, disassemble, or repair the analyser. This may cause an
unexpected accident or other trouble.
Troubleshooting
Problem
"
" appears on the display section
Switch or exchange the batteries.
"
" (error) is displayed
Did you step on the analyser during automatic correction (
"
" (error) is displayed
Did you move during measurement? How is your standing
position or posture?
"
" (error) is displayed during
Are the bottoms of your feet dirty?
measurement
Did you try to measure with socks or other footwear still on?
Using the analyser
Inserting the batteries
Placing the analyser
Place the analyser on a hard flat surface, such as a wooden floor.
Do not place the analyser on any of the following surfaces. Doing so may cause errors in the
measurement values.
• Sloped floor
• Soft surface, such as a rug
Measuring the weight of a baby or pet
Displays the difference in weight between the 1st and 2nd measurements to
measure the weight of a baby or pet. For the measurement method, see page 7.
Measuring only your weight
Measures only your weight. For the measurement method, see page 7.
The automatic 0.00 kg calibration and
correction function
The power is switched on and measurement is started by
simply stepping on the analyser. Accordingly, the analyser is
calibrated automatically to 0.00 kg periodically while the power
is switched off. However, calibration may not be performed
correctly in the situations listed below. Before using the
analyser for measurement, always place the analyser on a
hard surface with nothing on top of the analyser, and then
press either the Power button ( ) or Enter button (
• The analyser was stored standing up
• The analyser was stored with something on top of the
analyser
• The analyser was picked up and moved
* For use in Japan only.
* This manual is only a quick guide.
For greater details, see the manual included
with the product.
WARNING
Check points
1
On the rear surface of the analyser, push
the battery cover in the direction of the
arrow, and then remove it.
Insert the 3 included size AAA batteries
after checking the polarity ( / ). The
side with the spring is the negative ( )
side.
Attach the battery cover.
When the measurement values are obviously incorrect, perform the following procedure, and then measure again.
Place the analyser on a hard flat
surface.
Press either the Power button ( ) or
Enter button (
).
Make sure that "
Do not place anything on the analyser
).
or apply weight to the analyser while
"
" is displayed.
3
Part names
Elec-
trodes
Operation section
Display
section
Left button
(Back)
(Press and hold
to change
quickly.)
Weight mode button
(Press when measuring only your weight,
)?
or the weight of a baby or pet.)
Measuring body composition
The following 3 methods can be used to measure with this analyser.
Measure after automatic recognition of the user
The power is switched on and measurement is started by simply stepping on the analyser.
In addition, the user is recognized automatically from the registered users, and the measurement
results are recorded. (Limited to when the user number has been specified and measurement
has been performed at least once in the past.)
Step on while the power is off
Measure after specifying the user number
Specify the number of a registered user, and then measure. The user is matched reliably with
their registered data (more so than with automatic user recognition), and then the measurement
results are displayed. For the user registration and measurement methods, see pages 5 to 8.
Measure using Guest mode
An unregistered user can be measured. The measurement values cannot be recorded. For the
measurement method, see page 6.
Press the Enter button (
" is displayed.
Display
panel
Elec-
trodes
Battery cover
Battery exchange display
(Switches on when the battery must be replaced.)
Operation confirmation display
(Switches on if an operation button is pressed.)
Level display
(Displays the evaluation result.)
(Low)
(Normal)
Power button
(Press to switch the power on or off. The
power also switches on when you step on the
analyser. In such cases, the user number is
recognized automatically.)
Right button (forward)
(Press and hold to change quickly.)
Enter button
(Press to register, edit, or check users. Press to enter
settings during configuration. Press and hold to return
to the previous setting.)
2
Measuring
User number is displayed
).
Make sure that "0.00kg" is
displayed.
Press the Power button (
switch off the power.
4
(High)
) to
Need help?
Do you have a question about the HCS-FS02 Series and is the answer not in the manual?
Questions and answers