GSS GLC 100 Assembly Instructions Manual

Ethernet over coax

Advertisement

Quick Links

GSS
Grundig SAT Systems GmbH
Beuthener Strasse 43
D-90471 Nuremberg
Ethernet over Coax
Phone:
+49 (0) 911 / 703 8877
Fax:
+49 (0) 911 / 703 9210
E-mail:
info@gss.de
Internet:
http://www.gss.de/en
GLC 100
CLASS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GLC 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for GSS GLC 100

  • Page 1 GLC 100 Ethernet over Coax CLASS Phone: +49 (0) 911 / 703 8877 Grundig SAT Systems GmbH Fax: +49 (0) 911 / 703 9210 Beuthener Strasse 43 E-mail: info@gss.de D-90471 Nuremberg Internet: http://www.gss.de/en...
  • Page 2: Table Of Contents

    Feed in at the output of the broadband cable modem ....17 Commissioning ................18 Indicators ...................18 Power-LED ................18 EoC-LED ................18 LAN-LEDs ................18 Standby mode ................19 Factory defaults ................19 Security button ................19 6 Configuration .................... 20 Security function ................20 - 2 - GLC 100...
  • Page 3 Enter the device password ............24 Quality ..................25 Data rate (Mbps) ..............25 MAC address ................25 Add an external modem ............25 Firmware update ..............26 Create a private network ..............26 Diagnostics .................28 Info ....................29 8 Drill template .................... 30 - 3 - GLC 100...
  • Page 4: Safety Regulations And Notes

    • Do not place anything on the device which could initiate fires (e.g. candles) or contain liquids. • Do not use the device close to heating units or in direct sunlight. - 4 - GLC 100...
  • Page 5 European Council from January 27, 2003 which addresses old electronic and electrical devices, such devices must be disposed of at a designated collection facility. At the end of its service life, please take your device to one of these public collection facilities for proper disposal. - 5 - GLC 100...
  • Page 6: General Information

    2.1 P aC k i n g C o n t e n t s GLC 100 Power supply cable Network cable Termination resistor Brief assembly instructions 2.2 m...
  • Page 7: Description

    2.4 d es C r i P t i o n The GLC 100 is an "Ethernet over Coax" (EoC) modem which allows the feeding in of IP data signals (e.G. from the Internet, IPTV etc.) into an existing coaxial distribution system (in star or tree distribution).
  • Page 8: Assembly

    Internet must be possible, but not between the dif- ferent rooms. To achieve this, a so-called master / slave mode can be set. If you have any need for this, please contact your sales partner (www.gss.de -> Sales partners) because the network must be configured specifically for this purpose.
  • Page 9: Overview Of Gcl 100

    50-60Hz Reset Security LAN1 8 9 0 ! Power LED Power switch (ON/OFF) EoC LED LAN1 LED LAN2 LED LAN2 socket EoC socket TV socket Reset button Security button LAN1 socket Socket for mains cable - 9 - GLC 100...
  • Page 10: Installation And Commissioning

    EoC modems, in order to assign a private network name to all modems – centrally from one modem using the Configuration software (page 22). The MAC address and the corresponding password can be found on the sticker on the bottom of the device. - 10 - GLC 100...
  • Page 11: Installation

    CATV amplifier. Observe the examples on the following pages. If the TV socket of an EoC modem is not used, it must be terminated with the attached termination resistor! Power LAN1 LAN2 - 11 - GLC 100...
  • Page 12: Application Examples

    When feeding in IP data via the antenna socket, the terrestrial input of a SAT multiswitch, if not used for other purposes, must be connected to a terminating resistor of 75 Ω (e.g. FT 75). - 12 - GLC 100...
  • Page 13: Feed In Via The Input Of The Sat Multiswitch

    (e.g. SR 203) oper- ated in reverse direction. A commercially available high-pass filter , which blocks the return channel range, must be inserted in the coaxial line of the terrestrial signals. - 13 - GLC 100...
  • Page 14: Head-End Station

    OR… Power LAN1 LAN2 HbbTV DVB-C/T OR… Power LAN1 LAN2 Router A commercially available high-pass filter , which blocks the return channel range, must be inserted in the coaxial supply line from the head-end station. - 14 - GLC 100...
  • Page 15: Feed In At The Output Of The Head-End Station

    DVB-C/T OR… Power LAN1 LAN2 IPTV DVB-C/T OR… Power LAN1 LAN2 A commercially available high-pass filter , which blocks the return channel range, must be inserted in the coaxial supply line from the head-end station. - 15 - GLC 100...
  • Page 16: Broadband Cable

    For this reason, it must be ensured that the EoC signal does not cause distur- bances in the cable network via the point of interconnection (POI) – e.g. by using a commercially available high-pass filter at the output of the CATV amplifier. - 16 - GLC 100...
  • Page 17: Feed In At The Output Of The Broadband Cable Modem

    For this reason, it must be ensured that the EoC signal does not cause distur- bances in the cable network via the point of interconnection (POI) – e.g. by using a commercially available high-pass filter at the output of the CATV amplifier. - 17 - GLC 100...
  • Page 18: Commissioning

    (page 20), restore the factory setting on each device. After- wards, you can generate the key again. l an-led The LEDs LAN 1/2 ( ) light up if connections to connected devices are established. During data transfer the LEDs are flashing. - 18 - GLC 100...
  • Page 19: Standby Mode

    – delete the network key or – generate a private network. • Remove the cover from the button. The further procedure is described below (security function page 20). —> The Security button does not work in standby mode (page 19). - 19 - GLC 100...
  • Page 20: Configuration

    —> Please refer to the procedure described below. —> The key functions of a GLC 100 W modem (with WiFi function) are different to that of a GLC 100. For each type observe the cor- responding assembly instruction. – Define a network name for your EoC network with the help of the configura- tion software (page 22, download from http://www.gss.de).
  • Page 21: Integrate Further Devices

    (page 19), delete the network key again and try again to integrate the device to your private network. – Establish the connection using the configuration software which can be downloaded under http://www.gss.de. The operation of the configuration software is described from page 22 on. - 21 - GLC 100...
  • Page 22: Configuration Software

    With the Software "GSS.lan configuration" EoC modems are indicated in a network, network names are assigned and private and secured networks are created (128 Bit/AES Encryption).
  • Page 23: Operation

    7.2 o P e r at i o n • Start the "GSS.lan configuration" software. a i n m e n u The main menu displays all EoC modems, which are connected to the network and are "active" (which are not in standby mode).
  • Page 24: Rename A Device

    "Set Device Password" window. • Enter the password and confirm with "OK". The password is now checked and con- firmed in accordance. After that, the password will be displayed in the "Pass- word" column of the main menu. - 24 - GLC 100...
  • Page 25: Quality

    • Click on button "Add" to open the "Add Device to Network" window. • Enter a device name and the device password. —> The password is printed on the type label of the EoC modem. - 25 - GLC 100...
  • Page 26: Firmware Update

    P dat e You can use the "GSS.lan configuration" software to update the firmware of the EoC modem that is locally connected to the PC. The latest PIB and NVM firmware files are available on www.gss.de for download.
  • Page 27 After entering a private network name, all modems that are still in the "public" network ("HomePlugAV") are no longer displayed. This communication of the local modem with devices in the "public" network is effectively prevented. - 27 - GLC 100...
  • Page 28: Diagnostics

    The information displayed can be stored for later use in a text file. Modems that are no longer part of the network, can be deleted using the "Delete" but- ton. When trying to delete a device whose password has been entered, a dialogue screen for confirmation will appear. - 28 - GLC 100...
  • Page 29: Info

    / activated modems will be displayed in the lower section of the main menu. In order to update the network status at deactivated "AutoScan", click on but- ton "Scan" in the main menu (page 23). - 29 - GLC 100...
  • Page 30: Drill Template

    P l a t e 41 mm - 30 - GLC 100...
  • Page 31 Declaration of CE conformity - 31 - GLC 100...
  • Page 32 Service: Phone: +49 (0) 911 / 703 2221 • Fax: +49 (0) 911 / 703 2326 • Email: service@gss.de Grundig SAT Systems GmbH • Beuthener Straße 43 • D-90471 Nuremberg Alterations reserved. Technical data E. & O.E. © GSS GmbH...

Table of Contents