ECLE AR MIS T
Personal Humidifier
Instruction Manual
HCE-HU02
Series
For use in Hong Kong only.
If you made your purchase in another country, please refer to that country's manual.
http://www.elecom.co.jp/global/download-list/
Thank you for purchasing ECLEAR MIST.
This manual includes the user guide and precautions for safe handling of the product.
Please read this Instruction Manual before use. After reading, keep this manual safe
for future reference.
Part names
Make sure there are no missing parts before use. We make every effort to
ensure packaging is correct, but should there be any missing or damaged
items, please contact the shop you purchased the product from immediately.
Main unit
Cover
(Inner cover + Outer cover)
Jet
USB connector
slot
Outer cover
Line for
Drain
the maximum
water level
Water tank
Ultrasonic
Main unit
vibrator
Power button
Inlet port
(Mode switching button)
Dedicated USB cable
USB A connector
5
Safety Precautions
(Be sure to always follow these precautions.)
To prevent personal injury or damage to property of the user and any other
persons, please be sure to observe the precautions outlined below.
In the following table, degrees of possible damage or risk caused by misusing
this product against the precautions are described.
WARNINGS
This symbol indicates a high risk of death or serious injury.
This symbol indicates a possibility of injuries or property damage
CAUTIONS
only.
This symbol indicates a prohibited action that must not be performed.
This symbol indicates a mandatory action that must be performed.
WARNINGS
Keep out of reach of children. Never allow children to play with this product.
Laying the main unit or misusing the product may cause unexpected accidents.
Never disassemble or modify the main unit.
It will cause a fire or an electric shock.
Do not
disassemble
Always avoid forceful actions or shocks to the main unit, such as dropping or
hitting it.
The unit may be corrupted, which will cause a fire or an electric shock.
Never use the product when it is corrupted. When the product gets corrupted
during operation, turn off the power, remove the USB cable from the main
unit, and stop using the product.
It will cause a fire or an electric shock.
Do not soak the main unit or the USB cable in water, or spray water on it. Do
not use or keep the product in places with high humidity such as a bathroom
or a dressing room.
It could cause a fire, an electric shock, or a malfunction.
This product is not a medical inhalator.
Do not try to inhale directly the mist sprayed from the jet.
It could lead to deconditioning.
2
Preparation
1
Connect to a power source
Plug the USB micro B connector of the dedicated USB cable
into the USB connector slot of the main unit.
Inner cover
Plug the USB A connector of the dedicated USB cable into the
USB port of a PC or an AC adapter to supply the power.
PC
USB A connector
Dedicated USB cable
CAUTIONS
•
Use an AC adapter with the output of USB 5V/1A or more
Use of travel converters or other transformers for feeding may
•
cause excessive heating or lead to a fire.
Be sure to connect with the dedicated USB cable before
•
pouring water.
Receiving power from the USB port of a mobile battery is also
possible.
(Note that the product may not function properly with some
Vent
PCs, mobile batteries, or USB hubs)
USB micro B
connector
6
Never use this product for purposes other than as a humidifier or an aroma
diffuser.
It could cause accidents or malfunctions.
Do not insert foreign particles like a bobby pin or a piece of wire in the gap
of the jet, the main unit, etc.
It could cause an electric shock or injuries.
Do not use other detergents than kitchen detergent for the maintenance of
the main unit.
Such detergent remains in the water tank, and will generate a poisonous gas
or cause a malfunction. This will also lead to losing the antibacterial property of
the antibacterial-treated tank.
Do not use or keep this product in locations with:
direct sunlight
•
high temperature (e.g. near heaters)
•
high humidity (e.g. a bathroom)
•
a lot of dust
•
a lot of vibration
•
an unstable ground, such as an inclined stand;
•
or where the water in the tank freezes
•
where the inlet port may be blocked, such as on a shaggy rug, and
•
where the jet may be blocked (e.g. near curtains)
•
It could cause malfunctions or a fire.
Try to avoid touching mist or the main unit and ultrasonic vibrator during
operation or immediately after stopping the operation.
It could cause accidents or injuries.
Do not remove the outer cover during operation.
Otherwise, the water and/or the essential oil will spout out or leak into the main
unit to cause damage on the things near the product or the main unit.
Do not move the main unit during operation.
Turn off power and empty the water tank before moving the main unit. Or, the
water leaks into the main unit to cause malfunctions.
2
Prepare for using the product.
Remove the cover.
Use a glass, or similar, to pour tap-water
into the water tank. (Approx. 80 ml)
The tank capacity is approximately 80 ml.
Pour water up to not higher than the
maximum water level line.
Do not pour water through the jet with the
cover attached, or directly from the faucet.
CAUTIONS
Be sure to turn off the power for the main unit before pouring
•
USB micro B
water.
connector
•
To supply water, remove the cover, use a glass, or similar, and
gently pour water.
Never supply water during operation.
•
USB connector slot
When using an essential oil, make sure to
supply water into the water tank first, then
add a few drops of the oil.
Essential oils are not included.
When using oils, be sure to select
commercially available essential oils
obtained from 100% natural products.
CAUTIONS
Make sure to supply water up to the limit (80ml) in the water tank
first, then add some drops of the oil.
Do not drop the oil directly on the ultrasonic vibrator.
Attach the cover on the main unit.
Make sure that there are no gaps between the main unit and the
cover. Any gap may cause a water leak.
WARNINGS
Be sure to empty the water tank when you finish using the product. Be sure
to drain the water off from the outlet of the main unit to avoid pouring water
into the vent.
Although this product is made to be antibacterial, bacteria and/or mold may
propagate in the tank if remaining water exists. Pouring water into the vent will
cause malfunctions.
Never turn on power when the water tank is empty.
Or, the ultrasonic vibrator could burst, which causes malfunctions or a water leak.
Never pour liquids other than fresh tap-water at ordinary temperatures, or
essential oils, into the water tank.
Using other materials than tap-water and essential oils may cause malfunc-
tions. Note that it may give out a stench by using mineral water, alkaline ionized
water, well water, purified water, or similar.
CAUTIONS
When using any aroma oil, be sure to select essential oils obtained
from100% natural products.
Using those oils with synthetic perfume, impurities, or solid bodies may cause
malfunctions.
Please be careful not to spill the essential oil on the outside of the water
tank. The water tank and the inner cover are made with highly oil-resistive
materials, however, other parts of the product may be deformed due to the
component of some of the essential oils.
When the essential oil is spilled, wipe it off immediately.
Essential oils easily remain in the water tank. Please clean the tank regularly.
Please be careful not to overturn the product when using it near any
electronic device such as a PC or a TV set, or an article of specially coated
furniture. Make sure to place and use it on a stable location.
Remove the USB cable after using the product. Otherwise, unexpected
accidents may occur, for example, by tripping over the cable.
When disposing of this product, please do so in accordance with the
regulations of your municipality.
3
How to use
This product is designed for humidifying the air or perfuming the aromatic in
a small space only. This is not effective for the entire room.
LED light
Line for the maximum water level
Glass
By pressing the power button, you can change the flashing of the LED light.
The motion of changing the colors of the LED light gradually is called "gradation."
Power off
Light off
1
Turn on the power
Press the power button to turn on
power, effuse the mist, and start the
gradation of the LED light.
Essential oil
2
Change the motion of the LED light.
Press the power button during the gradation to stop the motion
of changing colors. Press the power button to select and fix
your favorite color.
Giving another press on the power button will turn off the LED light.
* Note that only the LED light can be changed by pressing the power
button. The amount of mist will not be changed.
3
Turn off power
Give a long press on the power button for about one second to
turn off the power. When using the product with the LED light
off, you can turn off the power by pressing the power button.
* When the water tank becomes empty, the power will be turned off
automatically.
7
CAUTIONS
4
Gradation colors
Gradation
· White · Red · Purple
· Blue · Light blue · Green
· Yellow
Light it with your
favorite color
The colors change in turn.
Power button
8
Need help?
Do you have a question about the HCE-HU02 series and is the answer not in the manual?