DeVilbiss DAD-500 Service Manual

DeVilbiss DAD-500 Service Manual

Desiccant air drying system

Advertisement

SERVICE MANUAL
EN
It is the Customer's responsibility to have all operators and service personnel read and understand this manual.
Contact your local DeVilbiss representative for additional copies of this manual.
READ ALL INSTRUCTIONS BEFORE OPERATING THIS DEVILBISS PRODUCT.
SB-6-156-R1 (3/2018)
DAD-500 (130026)
DESICCANT AIR DRYING SYSTEM
IMPORTANT! DO NOT DESTROY
1 / 8
www.carlisleft.com

Advertisement

Table of Contents
loading

Summary of Contents for DeVilbiss DAD-500

  • Page 1 IMPORTANT! DO NOT DESTROY It is the Customer's responsibility to have all operators and service personnel read and understand this manual. Contact your local DeVilbiss representative for additional copies of this manual. READ ALL INSTRUCTIONS BEFORE OPERATING THIS DEVILBISS PRODUCT.
  • Page 2 CA PROP PROP 65 WARNING WARNING: This product contains chemicals known The 25 CFM DAD-500 Desiccant Air Drying System to the State of California to cause cancer and birth is designed to be a point of use system. It is capable defects or other reproductive harm.
  • Page 3 Use only speci- Adjust regulator to desired setting by fied DeVilbiss parts. turning "T" handle in or out. Open ball valve to supply air to spray Risk of injury. Only use a socket guns or tool being used.
  • Page 4 21. Remove the brass bushing from the tank mended to check and clean/replace the using a 7/8" wrench. Using a large #3 Phil- *DAD-500 is supplied with an automatic filter element every 3-6 months. lips screwdriver, unscrew the filter. drain. If a 13-0041 (HAF-502) filter is ordered Remove the coalescing element (HAF- 22.
  • Page 5 Figure 3 HAF-505 55 CFM Oil Coalescing Filter PARTS LIST HAF-505 Ind. 9 (Optional) Replacement Description Parts Part No. Req. 1 (not shown) HAF-404 Filter Change Indicator (not shown) Cover O-Ring HAF-28 Filter and O-Ring Kit HAF-18 Automatic Drain HAF-8 Plastic Bowl HAF-19 Metal Bowl Guard...
  • Page 6 Compressor Main Min. Pipe Size Capacity Air Line Diameter Pipe union installed before DAD-500 allows easy installation and removal of the air drying system. 1-1/2 and 2 HP 6 to 9 CFM Over 50 ft. 3/4" 3 and 5 HP 12 to 20 CFM Up to 200 ft.
  • Page 7 NOTES SB-6-156-R1 (3/2018) 7 / 8 www.carlisleft.com...
  • Page 8 For specific warranty information please contact Carlisle Fluid Technologies. Carlisle Fluid Technologies is a global leader in innovative finishing technologies. Carlisle Fluid Technologies reserves the right to modify equipment specifications without prior notice. DeVilbiss , Ransburg , ms , BGK , and Binks ®...

Table of Contents