Summary of Contents for CSZ EZT-430i

  • Page 1 EZT-430i Single/Dual Loop Controller Configuration Manual...
  • Page 2 CAUTION or WARNING safety statement. Technical Assistance If you encounter a problem with your EZT-430i controller, review all of your configuration information to verify that your selections are consistent with your application: inputs; outputs; alarms; limits; etc. If the problem persists after checking the above, you can get technical assistance by dialing 1 (513) 772-8810 or by faxing your request to 1 (513) 772-9119, Monday thru Friday, 7:30 a.m.
  • Page 3: Table Of Contents

    EZT-430i What is EZT-430i? ..................... 1.1 Features ............................... 1.1 Configurator Overview ..................... 2.1 Configurator Menu ..........................2.2 Configuring EZT-430i ....................1 Loop Setup .............................. 1 Loop Address Utility ..........................2 User Communications ..........................3 Loop Configuration ..........................4 3.4.1 Input Sensor Selection ........................4 3.4.2...
  • Page 5: What Is Ezt-430I

    The built in Ethernet functionality includes a ‘Web Server’ to provide access to all EZT-430i data (view only), a VNC interface for remote control and monitoring and an NTS clock, all available via a local Intranet connection (wired or wireless), or the World Wide Web using standard software like Microsoft’s Internet...
  • Page 6 EZT-430i The EZT-430i controller includes the following features: • Single/Dual loop controller models (automatic program operation included). • Touch screen, “Smart Device” user interface (UI). • Video recorder mode for view only applications. • Email, SMS, FTP, VNC and Web functionality standard.
  • Page 7: Configurator Overview

    EZT-430i 2 Configurator Overview The EZT-430i configurator is a powerful tool that allows full customization of EZT-430i. It is a program that allows the OEM or user to set up control system options for the EZT-430i runtime application. configurator program will not run at the same time as the main runtime software.
  • Page 8: Configurator Menu

    The menu also provides access to edit the splash screen information that is shown when the runtime application starts. CSZ EZT-430i Configurator Overview...
  • Page 9: Configuring Ezt-430I

    The Units fields are used to enter the engineering units for the loop with up to four characters maximum. This value is shown on the single and dual view loop screens in the EZT-430i runtime application. When the loop input type selection is set for temperature, the field will be fixed at either “C” or “F” based on the units selection for the loop under loop setup.
  • Page 10: Loop Address Utility

    Loop Address Utility can be used. It is accessed from the Setup menu. In order to use the utility, only one loop control board can be connected to EZT-430i at a time. Since the default address of all control boards are 1, if more than one was connected, they would both respond to the same command which would cause them both to be set to a different address.
  • Page 11: User Communications

    3.3 User Communications The Modbus slave interface of EZT-430i can be set to operate in one of two modes. The default setting is to provide the standard user interface for use with CSZ’s Envision software. This selection assigns values to the Modbus slave register table in the proper positions to allow communications between EnVision and EZT-430i.
  • Page 12: Loop Configuration

    The loop control board is ordered with either a standard input for thermocouples and RTD’s, a voltage input or a milliamp input. The selected input type must be set to match the type of input supplied on the loop control board or the unit will not operate correctly. CSZ EZT-430i Configuring...
  • Page 13: Input Unit Selection

    0, the values are -32768 and 32767 respectively. For one decimal point, the values are -3276.8 and 3276.7. For two decimal digits, the values are -327.68 and 327.67 and for three decimal digits the values are -32.768 and 37.767. Configuring CSZ EZT-430i...
  • Page 14: Input Filter

    Loop Setup screen. IMPORTANT: If EZT-430i is set for dual loop operation, both loop control boards must be set to the same function and both inputs must be wired to the same control switch if automatic ramp/soak programs are to be used.
  • Page 15: Low/High Setpoint Limits

    Deactivating the input will then cause the program to go into hold. The input must then be reactivated in order for the program to resume operation. NOTE: EZT-430i does not support the P41/B42 event input functions of “Off Mode” and “PID2 Select”. These selections are not available through the EZT-430i configuration. 3.4.7...
  • Page 16: Output 1 Failure Transfer

    If the output function is set for on-off control, the failure transfer can be set to have the output turn on (1) or turn off (0) when a sensor break occurs. CSZ EZT-430i Configuring...
  • Page 17: Output 1 On-Off Control Hysteresis

    The output function must be set to match the type of output ordered on the loop control board. Relay, triac and SSR output types are used for proportioning control, alarm or event outputs. The isolated Vdc and mA output types are used for linear control. Configuring CSZ EZT-430i...
  • Page 18: Output 2 Failure Transfer

    The Event output function allows the output to be turned on and off via an automatic program or manually through the EZT-430i interface to act as a “soft” switch to turn system components on and off. The DC power supply output function must be selected when the output type ordered for the loop control board output 2 is a transmitter power supply.
  • Page 19: Output 3 Function

    The Event output function allows the output to be turned on and off via an automatic program or manually through the EZT-430i interface to act as a “soft” switch to turn system components on and off. The DC power supply output function must be selected when the output type ordered for the loop control board output 3 is a transmitter power supply.
  • Page 20: Output 4 Failure Transfer

    The Event output function allows the output to be turned on and off via an automatic program or manually through the EZT-430i interface to act as a “soft” switch to turn system components on and off. The Retransmit process value and Retransmit setpoint value functions allow the loop control board output to retransmit the current input value or set point to remote devices such as a chart recorder.
  • Page 21: Alarm (1-3) Function

    The alarm will turn off when another program is started, when power is cycled to the loop control board or when the “Reset” button is pressed on the Alarm screen of the runtime application. Note that this “alarm” is not indicated on the EZT-430i interface. Configuring CSZ EZT-430i A.13...
  • Page 22: Alarm (1-3) Mode

    (static) mode of operation. The alarm will turn off when the loop control is running an automatic program. Note that this “alarm” is not indicated on the EZT-430i interface. The Holdback mode alarm is not associated with the process value or set point. The alarm is turned on when the running program is in holdback.
  • Page 23: Alarm (1-3) Indication

    3.4.24 Alarm (1-3) Indication The Alarm 1, 2 and 3 Indication settings are used to select whether the alarm will be shown in the EZT-430i runtime application or be hidden from the user. This allows the OEM to configure an alarm to perform a specific control function while preventing the user from adjusting the set point or seeing the activation state of the alarm.
  • Page 24: Setpoint At Start Of Automatic Program

    Loop Setup screen. NOTE: If EZT-430i is set for dual loop operation, it is recommended that both loop control boards be set to the same selection so that both loop controls start an automatic ramp/soak program in the same manner to avoid operator confusion.
  • Page 25: Power Fail Recovery

    “Done” button to set the power recovery mode for the loop control board and return to the main Loop Setup screen. IMPORTANT: If EZT-430i is set for dual loop operation, both loop control boards must be set to the same recovery setting. If the recovery mode for both loop control boards is not identical, program operation of one loop may continue while the other is terminated which will cause a program run error alarm to occur as well as result in incorrect operation of the program.
  • Page 26: Enabling Holdback

    EZT-430i configuration. 3.4.29.1 Enabling Holdback For single loop systems, holdback is enabled under program entry of the EZT-430i runtime application. The user is then able to select the desired hold type for each program step. For dual loop systems, holdback operation is conditional based on the configuration of the loop controls.
  • Page 27 By using the external relay, when the loop exits its holdback condition, its hold input will be triggered if the other loop is still in holdback, thus allowing it to enter the hold condition and continue waiting for the other loop to have its holdback condition satisfied. Configuring CSZ EZT-430i A.19...
  • Page 28: Calibration

    EZT-430i 3.5 Calibration Each EZT-430i loop control is calibrated at the factory before shipment; however, they can be recalibrated in the field with the use of proper calibration equipment. While the basic calibration of the unit is highly stable and set for life, the Loop 1 and Loop 2 Input offset calibration provides the means to offset the permanent factory calibration.
  • Page 29: Functions

    EZT-430i 3.6 Functions The EZT-430i functions are accessed from the “Startup” menu and allow the OEM to select which screens/menu items will be enabled (shown) in the EZT-430i runtime application. These functions can be used to customize the system to meet specific requirements.
  • Page 30 NOTE: If data logging is set to log on program operation or when EZT-430i starts and this menu is then disabled, data logging will be disabled. This menu item must remain visible in order for the built in data logging of EZT- 430i to function.
  • Page 31 PV is shown for view/data log mimicking a typical chart recorder NOTE: When activated, this automatically turns off all automated program functions, loop tuning and set point limit access. Configuring CSZ EZT-430i A.23...
  • Page 32: Startup View

    The available selections are Single loop View, Dual loop View, Chart View, Event Control, Alarm View and Alarm Log. NOTE: If the selected screen to view on startup is disabled in the EZT-430i functions list, the screen will only be available when the “Home” icon is pressed. A.24...
  • Page 33: Alarm/Event Tagnames

    Event screens. This allows each event to be identified by the function it performs for the end user. To change the name of an event, select the event from the list and press the “Edit” button to enter the desired text up to 9 characters. Configuring CSZ EZT-430i A.25...
  • Page 34: Custom Name\Address

    The ‘Custom Name\Address’ screen is accessed from the ‘Tagnames’ menu and allows the OEM to configure the main splash screen when the EZT-430i runtime application starts. This is used so the OEM name and contact information is shown each time the EZT-430i controller is powered up. It also allows the OEM to change the name of the controller to adapt it to a specific product or market.

Table of Contents