ToxiRAE Pro LEL
QuickStart Guide
For Sales & Service Contact
San Jose, CA 95134-1708
2650 E. 40th Ave. • Denver, CO 80205
Phone 303-320-4764 • Fax 303-322-7242
1-800-833-7958
www.geotechenv.com
Charging The ToxiRAE Pro LEL
Always fully charge the battery before use. Contacts on
the bottom of the ToxiRAE Pro LEL meet the cradle's
contact pins, transferring power. While charging, the
LED on the cradle glows red. When the battery is fully
charged, the LED glows green.
A
Place ToxiRAE
B
Pro LEL in
charging cradle
Raised lip
locks into
cradle's
latch
Charging
Latch
status LED
release
The ToxiRAE Pro LEL User's Guide must be
carefully read by all individuals who have or will
have the responsibility of using, maintaining, or
servicing this product. The product will perform as
designed only if it is used, maintained, and serviced
in accordance with the manufacturer's instructions.
Never operate the monitor when the cover is
removed. Remove monitor top cap, rear cover, and
battery only in an area known to be non-hazardous.
Turning The ToxiRAE Pro LEL On
Press and hold [MODE] for 3 seconds. During
startup, the battery, buzzer, vibration alarm, and
LEDs are tested, and then the ToxiRAE Pro LEL
performs self-testing of its functions. When the
main measurement screen appears, the ToxiRAE
Pro LEL is ready for calibration or use.
Connect AC
adapter to charging
Note: If the battery is almost fully discharged, the
cradle and
message "Battery too low! Needs charging.
plug it into AC
Powering off!" shows in the display and the
power source
ToxiRAE Pro LEL shuts off. You must charge the
battery before you can use the instrument.
4.
WARNINGS
Read Before Operating
CAUTION!
User Interface
The ToxiRAE Pro LEL's user interface consists of
the display, four LED lights, an alarm buzzer, and two
keys, [MODE] and [Y/+]. The LCD displays real-
time reading in specified measurement units, sensor
type, alarm type (when in alarm, including cal.
overdue), battery status, datalog (if on), and radio and
connection quality (if available).
Gas inlet
LEDs
Display
[MODE] key
2.
Turning The ToxiRAE Pro LEL Off
Press and hold [MODE]. A 5-second countdown to
shutoff begins. You must continue pressing on the
key for the entire shutoff process. If you remove
your finger from the key during the countdown, the
shutoff operation is canceled and the ToxiRAE Pro
LEL continues normal operation.
When the countdown beeps stop and you see "Unit
Off," release your finger from the [MODE] key.
The ToxiRAE Pro LEL is now off.
5.
Belt clip (on back)
LED
Alarm
Buzzer
[Y/+] key
3.
6.

Advertisement

loading

Summary of Contents for Geotech ToxiRAE Pro LEL

  • Page 1 Press and hold [MODE] for 3 seconds. During Press and hold [MODE]. A 5-second countdown to the bottom of the ToxiRAE Pro LEL meet the cradle’s startup, the battery, buzzer, vibration alarm, and shutoff begins. You must continue pressing on the contact pins, transferring power.
  • Page 2 Calibration Zero (Fresh Air) Calibration Manual Span Calibration The ToxiRAE Pro LEL can be automatically bump tested The ToxiRAE Pro LEL should be zero-calibrated in In Programming Mode, and with “Span Calib” highlighted: and calibrated using the AutoRAE 2 Test and Calibration clean air with 20.9% oxygen.