Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Snell Manuals
Transmitter
IQOTX81
User manual
Snell IQOTX81 User Manual
3g/hd/sd-sdi multi-channel fiber transmitter
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
page
of
25
Go
/
25
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Module Description
Block Diagram
Rear Panel View
Order Codes
Feature Summary
Technical Profile
Inputs and Outputs
Controls
Specifications
Connections
SDI Inputs
Fiber Outputs
Card Edge Controls
Controlling the IQOTX80/81/82/83/84/99 from the Rollcall Control Panel
Unit Status
System-Setup Screen
SDI-Inputs 1-4 Screen
SDI-Inputs 5-8 Screen
Output-Fiber Screen
System-Memory 1-16 Screen
Logging
Rollcall Log Fields
System-Rolltrack Screen
To Configure a Rolltrack Action
Viewing Rolltrack Information
Advertisement
Quick Links
1
Block Diagram
2
Module Description
Download this manual
User Manual
IQOTX80, IQOTX81, IQOTX82
IQOTX83, IQOTX84, IQOTX99
3G/HD/SD-SDI Multi-Channel Fiber
Transmitter
snellgroup.com
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the IQOTX81 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Snell IQOTX81
Transmitter Snell IQOTX30 Operator's Manual
Fiber optic transmitters for 3g/hd/hd-sdi signals (27 pages)
Summary of Contents for Snell IQOTX81
Page 1
User Manual IQOTX80, IQOTX81, IQOTX82 IQOTX83, IQOTX84, IQOTX99 3G/HD/SD-SDI Multi-Channel Fiber Transmitter snellgroup.com...
Page 2: Table Of Contents
The different versions of the standard product simply have different wavelength fiber transmitters fitted. Issue 1 Rev 2 Page 2 © 2012 Snell Limited...
Page 3: Module Description
Single width Fibre and HD BNC ( SER IN 2 FIBER OUT 2 FIBER OUT 1 IQOTX8_80-2A3) Double width Fibre and BNC ( SERIAL IN 2 SERIAL IN 1 FIBER OUT 2 FIBER OUT 1 Issue 1 Rev 2 Page 3 © 2012 Snell Limited...
Page 4: Order Codes
Versions of the module cards available are: SFP fit options for different wavelength operation. CH1/2 CH3/4 CH5/6 CH7/8 IQOTX80 Dual 1310nm Dual 1310nm Dual 1310nm Dual 1310nm IQOTX81 Dual 1550nm Dual 1550nm Dual 1550nm Dual 1550nm IQOTX82 1270/1290nm 1310/1330nm 1350/1370nm 1390/1410nm IQOTX83 1470/1490nm 1510/1530nm...
Page 5: Technical Profile
Present, Loss, Unknown, Unrouted, Data Rate Laser disable On/Off Logging Input 1-8 Type Input 1-8 Bit Rate Input 1-8 Present Input 1-8 Loss Output 1-8 laser bias Output 1-8 laser power Output 1-8 laser wavelength Issue 1 Rev 2 Page 5 © 2012 Snell Limited...
Page 6: Specifications
3 Gbps SDI, SMPTE 424M, 1.5 Gbps HD-SDI, SMPTE 292M 270 Mbps SDI, SMPTE 259MC / DVB-ASI Connector / format BNC/ 75 Ohm panel jack on standard Snell connector panel Return loss >-15 dB (270 Mbps, 1.5 Gbps) >-10 dB (3 Gbps) Output jitter SD-SDI 0.2 UI (10 Hz) / 0.2 UI (1 kHz)
Page 7: Connections
FIBER OUT 2 FIBER OUT 1 IQOTX8_80-2A3 Fiber outputs from the unit are made via 8 LC connectors. SERIAL IN 2 SERIAL IN 1 FIBER OUT 2 FIBER OUT 1 Issue 1 Rev 2 Page 7 © 2012 Snell Limited...
Page 8: Card Edge Controls
Flashes to indicate that an SFP status warning has been activated (e.g. temperature or supply voltage) other than the Rx Power Warning. Good (Green) Illuminates to indicate all SFPs are fitted and functioning correctly. Issue 1 Rev 2 Page 8 © 2012 Snell Limited...
Page 9: Controlling The Iqotx80/81/82/83/84/99 From The Rollcall Control Panel
NONE indicates that a Fiber Transmitter is missing or a Receiver fitted by mistake. ‘Blank’ status indicates that the product does require a Fiber Transmitter to be fitted for that channel (applies to IQOTX99). Issue 1 Rev 2 Page 9 © 2012 Snell Limited...
Page 10: System-Setup Screen
Input 1-8 Name: The bottom half of the screen has entry fields for 8 Input Names. These are the input names displayed in logging. To change a name, type the name in the text field and click S. To return the name to its factory default, click P. Issue 1 Rev 2 Page 10 © 2012 Snell Limited...
Page 11: Sdi-Inputs 1-4 Screen
Reclock Bypass: Check this to bypass the reclocker, which is on the output signal. • The Channel Ident, I/P Name, I/P State and I/P Rate are shown for each channel. Issue 1 Rev 2 Page 11 © 2012 Snell Limited...
Page 12
Config 1, the Secondary must be routed in Config 2. Also, to prevent the configuration switching backwards and forwards between configurations, it must also be routed in Config 1. Issue 1 Rev 2 Page 12 © 2012 Snell Limited...
Page 13: Sdi-Inputs 5-8 Screen
Reclock Bypass: Check this to bypass the reclocker, which is on the output signal. • The Channel Ident, I/P Name, I/P State and I/P Rate are shown for each channel. Issue 1 Rev 2 Page 13 © 2012 Snell Limited...
Page 14
Config 1, the Secondary must be routed in Config 2. Also, to prevent the configuration switching backwards and forwards between configurations, it must also be routed in Config 1. Issue 1 Rev 2 Page 14 © 2012 Snell Limited...
Page 15: Output-Fiber Screen
The Output-Fiber screen shows status associated with the fiber transmitters. Fiber Optic Tx 1-8 Shows the fiber transmitter status for each channel. SFP Status relates to the product SPF fit. Issue 1 Rev 2 Page 15 © 2012 Snell Limited...
Page 16: System-Memory 1-16 Screen
To recall a memory: • In the Recall Memory column, select the memory to recall. The recalled set-tings will be applied and the memory name will appear in the Last Recalled Memory section. Issue 1 Rev 2 Page 16 © 2012 Snell Limited...
Page 17: Logging
Logged parameters are made available to logging devices connected to the RollCall Network. They are also displayed on a number of RollCall Screens where they can selectively be switched off to prevent them being logged externally. Issue 1 Rev 2 Page 17 © 2012 Snell Limited...
Page 18
IQOTX80/81/82/83/84/99 www.snellgroup.com Issue 1 Rev 2 Page 18 © 2012 Snell Limited...
Page 19
IQOTX80/81/82/83/84/99 www.snellgroup.com Issue 1 Rev 2 Page 19 © 2012 Snell Limited...
Page 20
IQOTX80/81/82/83/84/99 www.snellgroup.com Issue 1 Rev 2 Page 20 © 2012 Snell Limited...
Page 21
Log Enable: Select the check boxes that correspond to the parameters for which log information should be collected. • Log Field: Displays the name of the logging field. • Log Value: Displays the current log value. Issue 1 Rev 2 Page 21 © 2012 Snell Limited...
Page 22: Rollcall Log Fields
<SFP fit status for Fiber O/P 8> OUTPUT_1_LASER_BIAS_STATE <Tx SFP 1 laser bias current alarm/warning state> WARN:LOW FAIL:LOW WARN:HI FAIL:HI OK:OFF <blank> (SFP fit error) … OUTPUT_8_LASER_BIAS_STATE <Tx SFP 8 laser bias current alarm/warning state> Issue 1 Rev 2 Page 22 © 2012 Snell Limited...
Page 23
OUTPUT_1_TX_POWER <Tx SFP 1 laser power> … … … OUTPUT_8_TX_POWER <Tx SFP 8 laser power> -2.4dBm OUTPUT_1_WAVELENGTH <Tx SFP 1 wavelength> 1310nm … … OUTPUT_8_WAVELENGTH <Tx SFP 8 wavelength> 1310nm Issue 1 Rev 2 Page 23 © 2012 Snell Limited...
Page 24: System-Rolltrack Screen
Using RollTracks To enable or disable RollTrack functions: • To disable RollTrack functions, select the Disable All check box. • To enable the RollTrack functions, clear the Disable All check box. Issue 1 Rev 2 Page 24 © 2012 Snell Limited...
Page 25: To Configure A Rolltrack Action
Bad: RollTrack message has not been sent correctly, acknowledged at the destination unit. This could be because the destination unit is not of the type specified. Disabled: RollTrack sending is disabled. Issue 1 Rev 2 Page 25 © 2012 Snell Limited...
This manual is also suitable for:
Iqotx80
Iqotx82
Iqotx83
Iqotx84
Iqotx99
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the IQOTX81 and is the answer not in the manual?
Questions and answers