AQUATECH CAN165BM-100 Manual

165 series birm filter

Advertisement

165 Series Manual
Birm Filter
Note:
1. Read all instructions carefully before operation.
2. Avoid pinched o-rings during installation by applying
(provided with install kit) NSF certified lubricant to all seals.
Rev 4 December 28, 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CAN165BM-100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AQUATECH CAN165BM-100

  • Page 1 165 Series Manual Birm Filter Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant to all seals. Rev 4 December 28, 2011...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS System Specifications......................3 How Your System Works ....................... 3 Programming ........................5 Sizing Requirements ......................6 Before Installation ........................ 8 General Installation ......................10 Start Up ..........................12 Maintenance ........................15 Control Valve Exploded View ....................16 Control Valve Parts List .......................
  • Page 3: System Specifications

    System Specifications Birm Filter The birm filter contains media which removes soluble and precipitated iron without the use of chemicals. Periodic backwashing cleans the bed. Caution: These water filters are not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
  • Page 4 Display DISPLAY MENU Menu DOWN Down SET&REGEN. Change Program Manual Regeneration Figure 1. Valve Display MENU BUTTON “ ”: The function of this key to enter the level one programming mode where the valve settings can be adjusted. ”: CHANGE / REGEN “ This button has two functions.
  • Page 5: Programming

    Programming 1. Press ‘ ’ to enter programming. If the system has been inactive, you may have to hold and press ‘ ’ until you hear a beep to unlock the display screen. Press ‘ ’ or ‘ ’ to select which setting to modify. 2.
  • Page 6: Sizing Requirements

    Program Options Depending on the current option settings, some parameters cannot be viewed or set. Program Mode DESCRIPTION PARAMETER OPTIONS This option controls whether cubic meters or US gallons is used for the volume display and the format REGIONAL METRIC of the day, year, and month.
  • Page 7 CHECK YOUR WATER PRESSURE AND PUMPING RATE Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipment damage: 1. Minimum water pressure required at the filter tank inlet is 25 psi. If pressure is over 50 psi, a pressure reducing valve must be installed in the water supply line ahead of the hydro-charger (Fig.
  • Page 8: Before Installation

    Total amount of iron to be removed between regenerations - ÷ ppm of iron to be removed per day = NUMBER OF DAYS BETWEEN REGENERATIONS EXAMPLE: 5 people in the household x 75 gallons of filtered water per person = 375 gallons of filtered per day ppm of compensated iron - 4 is the minimum setting of compensated iron = 1,500...
  • Page 9 HYDROGEN SULFIDE (H Hydrogen sulphide (often referred to as “sulphur”), is easily detectable by its objectionable “rotten egg” odour. Sulphur corrodes iron, brass, copper and silver. A chemical free iron filter is not recommended when hydrogen sulphide is present. Please contact your Independent Water Tech representative for further recommendations.
  • Page 10: General Installation

    General Installation Water Pressure Minimum 25 PSI Electrical Supply Uninterrupted AC 115V Existing Plumbing Free of any deposits or build-ups inside pipes. Unit Location Locate close to drain and connect according to plumbing codes Bypass Valves Always provide for bypass valve if unit is not equipped with one. Softener and or other water treatment equipment should be installed to local plumbing codes Plumbing...
  • Page 11 1. Locate the filter tank close to a drain where the system will be installed. The surface should be clean and level. 2. Shut off all water at main supply. On a private well system, turn off power to pump and drain pressure tank. Make certain pressure is relieved from complete system by opening nearest faucet to drain the system.
  • Page 12: Start Up

    Special Instructions for Split-Stream and Public Water Supply Installations For a split-stream installation, a secondary pressure tank must be installed as shown in the split-stream installation diagram (Page 10). On a public water supply installation, a pressure tank must be installed as shown in the public water supply installation diagram (Page 10).
  • Page 13 The plumbing system and water using appliances that have been exposed, even for a short time, to iron-fouled water need to be cleaned of the precipitated iron that has collected in them or iron bleed (staining) will continue to be a problem. Depending on the amount of iron in the water and the length of time the water system has been exposed to iron fouling, select from the following procedures those that apply to the type of system and appliances that need to be cleaned to assure iron-free water at all points of use.
  • Page 14 Drain Line Flow Control Suggested Filter Valve Configuration Drain Line Flow Tank Size (Diameter) Control (DLFC) 8" #4 (3.5 GPM) 9" #6 (4.0 GPM) 10" #7 (5.0 GPM) 12" none Figure 9. Valve Configuration Figure 10. Injector Assembly Installation Of Bypass Figure 11.Bypass Exploded View Automatic Bypass The regeneration cycle lasts approximately 1/2 hour, after which filtered water service will be restored.
  • Page 15: Maintenance

    Maintenance Maintenance of your new water filter requires very little time or effort but it is essential. Regular maintenance will ensure many years of efficient and trouble-free operation. 1. Periodically make sure your pump is performing satisfactorily to ensure sufficient water is available for backwashing the filter. 2.
  • Page 16: Control Valve Exploded View

    Control Valve Assembly Exploded View See parts listing on next page (17)
  • Page 17: Control Valve Parts List

    Control Valve Parts List I t em N o. P art N o. P art D i scri pt i on Q uant i t y A 01 05056087 S crew -M 5× 12(H exagon) A 02 05056088 S crew -M 5× 16(H exagon w i t h W asher) A 03 05056047 E nd P l ug R et ai ner...
  • Page 18: Trouble Shooting

    Trouble Shooting Issue Possible Cause Possible Solution 1. Insufficient air drawn by the air injector Check air injector adjustment. If unable to adjust A. Water clear when drawn; turns red upon standing (stain for long enough draw, check pumping rate. producing) 2.
  • Page 19: Warranty

    Manufacturers Warranty Canature North America Inc. warrants that your new filter is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble-free service. Five Year Complete Parts Guarantee Canature North America Inc. will replace any part which fails within 60 months from date of manufacture, as indicated by the serial number, provided the failure is due to a defect in material or workmanship.

This manual is also suitable for:

Can165bm-150Can165bm-75

Table of Contents