  • Page 1 RPT-100 Date 2017-08-03 User Manual Page RPT-100 User Manual CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 2 User Manual Page 1. All contents of this manual and the software of RPT-100 are protected by copyright law, all rights are reserved by GEN2WAVE Co., Ltd. 2. No part may be photocopied, reproduced, or translated into another language without the prior written consent of this document.
  • Page 3: Table Of Contents

    Function and Layout ........................... 10 2.4. Status Display LED..........................10 2.5. Basic Screen ............................. 10 3. BASIC USAGE .......................... 11 3.1. Key Description ............................11 3.2. Power On/Off ............................12 CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 4 4.2.1. BlueTooth ..............................18 4.2.2. Search Reader ............................19 4.2.3. Device Config ............................23 4.2.4. UHF RFID Config ........................... 24 4.2.5. Scanner Config ............................39 4.3. Scan Tab ..............................59 CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 5 Program Introduction ......................... 69 5.2. User Interface information ......................69 5.3. How to Use............................... 70 6. TAGFOCUS AND FASTID TAG SUPPORTED ............... 72 6.1. Type of tags supported ........................72 CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 6 9.3. How to disconnect ..........................79 9.4. How to set Enter as termination character ................79 9.4.1. F/W 5.1.0.6 or above .......................... 79 9.4.2. F/W 5.1.0.5 or less ..........................80 CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 7: Manual Information

    GEN2WAVE will respond to your inquiries by e-mail, telephone or fax within the time limit specified in the support contract. If GEN2WAVE Support is unable to resolve your issue, you may need to return your equipment to receive service. In these cases, specific instructions are provided. GEN2WAVE shall not be liable for any damages incurred during carriage unless approved transport packaging is used.
  • Page 8: Product Introduction

    Duty 50% : 3hr Charging port Micro USB, Magconn Charge input 1.0A / Full charge 5hrs Dust & water resistance IP68 (Micro-USB cap must be closed for water resistance) Drop 1.5M CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 9: Package Components

    RPT-100 Date 2017-08-03 User Manual Page 2.2. Package Components CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 10: Function And Layout

    USB/Magconn™ connection status ◐◐ Red, Green blink Bluetooth module initialize Bluetooth ● Bluetooth connection stand-by ● Green Bluetooth connection status ● Battery charging Battery ● Green Battery fully charged 2.5. Basic Screen CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 11: Basic Usage

    29% ~ 10% 10% below Insufficient Model name– MAC address last four digits MAC address F/W version 3. Basic usage 3.1. Key Description Name Function Power Press and hold: Power On/Off CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 12: Power On/Off

    Scanner decode start/end Scanner (Note: Not operational in Dual mode) 3.2. Power On/Off Hold and press the device’s Power key for 2~3 seconds in order to turn the device on or off. CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 13: Rfid Tag Reading

    The stored data can be transmitted in conjunction with the application program. CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 14: Trigger Mode

    When the RFID key is pressed again, the Dual RFID and the SCANNER stop working. The SCANNER button does not respond. Generally, it is used in a stationary form. CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 15: Operation Mode

    If your PC does not support Bluetooth function, you can connect the DOTD-100 (sold separately) to the PC and transfer data to PC D100 wirelessly. For detailed information, refer to 오류! 참조 원본을 찾을 수 없습니다.. CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 16: Delete Data

    When deleting is complete, the count value is initialized to 0, and a buzzer will sound. 3.8. Reset Data Using a pointed tool, press Reset key to restart the device. Data stored in the internal memory is not lost. CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 17: Android Test Program

    Page 4. ANDROID TEST PROGRAM 4.1. Download & Installation Download apk file. 4.2. Config Tab Config Tab is a for device connection and UHF RFID / Scanner Configuration [Config Tab] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 18: Bluetooth

    In Bluetooth Off status, only Bluetooth button become active and it can be turned on. When the Bluetooth is on, "Connect Reader" and "Search Reader" Button turn active. [Bluetooth Off] [Bluetooth On] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 19: Search Reader

    User Manual Page 4.2.2. Search Reader Press "Search Reader" Button to search device. Start searching for devices at the same time as switching the screen. [Search Reader Button] [Search Devices] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 20 Press "Connect" Button to connect with device or Click the "Cancel" Button to close the window. Press the button at the top right to search for devices [Before connecting to device] [Confirm device connection] [Status of connection] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 21 When you select a device in the "Connected" state in the Device List, Window will be appeared whether you confirm to disconnect and click the "Disconnect" button to disconnect. [Status of connection ] [Confirm to disconnect] [Status of Disconnection] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 22 It can be checked current version for application and device. Click on “Sub Menu”button on the upper right and then “About” button will appear. You can simply check information for the device with clicking on “About” [Sub Menu Button] [About Button] [Information] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 23: Device Config

    RPT-100 Date 2017-08-03 User Manual Page 4.2.3. Device Config Tap "Device Config" Button to change the set-up for "Device Config". [Device Config Button] [Device Config Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 24: Uhf Rfid Config

    Date 2017-08-03 User Manual Page 4.2.4. UHF RFID Config Tap "UHF RFID Config" Button to change the set-up for "UHF RFID Config". [UHF RFID Config Button] [UHF RFID Config Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 25 It is returning time that the inventory flag of the tag returns A to B and back to A. Set the time taken to re-read the tag once read for Multi Reading. [Session Button] [Session set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 26 The lower value is fit to read small amount of tags faster. The higher value can read more tags at a time. In case of multi reading, setting value 5 is best option to stable reading speed [Q Button] [Q set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 27 Set the Inventory Flag of the tag to be read. A mode is best option to Multi Reading, and AB is best option to single reading in a quick. [Target Button] [Target Set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 28 It can be changed UHF RFID TX Power of the device (30dBm ~ 0dBm). Reading distance is adjustable to TX power level. At Max 30dBm, reading distance can be longer but battery consumption will increase [Radio Power Button] [Radio Power set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 29 Set up reading speed for the tag. The higher cycle rate increase reading speed for tag but the battery consumption is increased. We recommend to set up below 40%. [Tx Cycle Button] [Tx Cycle set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 30 RPT-100 Date 2017-08-03 User Manual Page 4.2.4.6. Inventory Config Configuration for reading UHF RFID Tag [Inventory Config Button] [Inventory Config Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 31 Page 4.2.4.6.1. Inventory Mode UHF RFID mode for reading tag can be changed (Continuous or Single). In case of Single mode, device read tag one by one. [Inventory Mode Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 32 It can be set up time to take reading UHF Tag (Unlimited ~ 120min). When set-up time is over, reading tag is stopped. When set to 0, it is unlimited time to read tag [Inventory Timeout Button] [Inventory Timeout set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 33 When the device read UHF RFID tag, it is selectable whether to transmit Tag reading time (Enable / Disable). It can be transmitted tag reading time based on the device time. [Report Time Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 34 It is selectable to transmit RSSI data when device read UHF RFID tag(Enable/Disable) It can be transmitted Received Signal Strength Indication (RSSI) value which is receiving strength indicator [Report RSSI Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 35 Session 01, Target A only is available for Tag Focus and refer to UHF Tag list supported to Tag Focus and FastID [Tag Focus Button(Inactive)] [Tag Focus Button(Active)] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 36 It is selectable to FastID function(Enable/Disable). This mode improves inventory check time based on TID while getting TID value during inventory. Refer to UHF Tag list supported to Tag Focus and FastID [FastID Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 37 RPT-100 Date 2017-08-03 User Manual Page 4.2.4.9. Data Format When reading UHF RFID tag, you can set the data format to be transmitted. [Data Format Button] [Data Format set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 38 RPT-100 Date 2017-08-03 User Manual Page 4.2.4.10. Factory Reset Initializes UHF RFID settings of the device. Tap "YES" button to proceed. [Factory Reset Button] [Factory Reset Window] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 39: Scanner Config

    RPT-100 Date 2017-08-03 User Manual Page 4.2.5. Scanner Config Tap "Scanner Config" Button to enter "Scanner Config" screen to be set up. [Scanner Config Button] [Scanner Config Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 40 RPT-100 Date 2017-08-03 User Manual Page 4.2.5.1. Scanning Preferences Tap "Scanning Preferences" button to enter "Scanning Preferences" screen. [Scanning Preferences Button] [Scanning Preferences set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 41 4.2.5.1.1. Decode Session Timeout Tap "Decode Session Timeout" Button to enter "Decode Session Timeout"(500ms ~ 9900ms) to be set decode session timeout. [Decode Session Timeout Button] [Decode Session Timeout set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 42 Tap "FNC1" Button to enter FNC1 setting. You can specify FNC1 value contained in GS1 bar code (GS1-128, GS1-Databar, GS1-DataMatrix) and Code-128 bar code to transmit it to other device [FNC1 Button] [FNC1 set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 43 Tap "Inverse 1D" Button to enter 1D Barcode Inverse setting. You can select it among three kind of mode. When black and white bar is reversed, it can be set up inverse detection [Inverse1D Button] [Inverse1D 설정 Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 44 Tap "Inverse2D" Button to change the 2D Barcode Inverse setting. It is selectable whether to read 2D bar codes with black pattern and white pattern reversed each other. [Inverse2D Button] [Inverse2D set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 45 You can select "Picklist Mode" function (Enable / Disable). When is set to enable, only the bar code located at the center of the Aimer Pattern is read. [Picklist Mode Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 46 Page 4.2.5.1.6. Mirrored Image You can select "Mirrored Image" function (Enable / Disable). When is set to enable, reads barcode horizontally changed as seen through the mirror. [Mirrored Image Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 47 You can select "Mobile Phone / Display Mode" function (Enable / Disable). When is set to enable, improves performance for reading bar code output to display of mobile phones and electronic displays. [Mobile Phone / Display Mode Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 48 Date 2017-08-03 User Manual Page 4.2.5.1.8. Decoding Illumination You can select "Decoding Illumination" function (Enable / Disable). When barcode is read, it is selectable to output light. [Decoding Illumination Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 49 It is selectable to "Decode Aiming Pattern" function (Enable / Disable). Set whether to output the aiming pattern, which allows user to aim reading barcode position when reading a barcode. [Decode Aiming Pattern Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 50 It sets decoding level when reading Quiet Zone attenuated than the standard (from the start to end of the bar code) [1D Quiet Zone Button] [1D Quiet Zone set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 51 You can select "Intercharacter Gap Size"(Normal / Large). In case of Intercharacter Gap Size is larger than the maximum allowable size at Code3 and Coda bar, when the barcode is not readable, It should be set to large [Intercharacter Gap Size Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 52 Page 4.2.5.1.12. Fuzzy 1D Processing You can select "Fuzzy 1D Processing" function (Enable / Disable). When is enable, improves reading performance for damaged 1D bar code. [Fuzzy 1D Processing Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 53 Tap "Symbologies" button to be set to "Symbologies". You can select "Barcode Type" function by switching enable or disable button on the right side of each symbology (Enable / Disable) [Symbologies Button] [Symbologies set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 54 Config" window will be appeared then Barcode Type List will be displayed. When Barcode type is selected, it can be set up detail parameter for each of those. [Sub Menu Button] [Advanced Config Button] [Advanced Config List] [UPC / EAN set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 55 RPT-100 Date 2017-08-03 User Manual Page 4.2.5.3. Data Format Tap “Data Format” to set up data format when reading barcode [Data Format Button] [Data Format set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 56 User Manual Page 4.2.5.4. Redundancy & Security Level Tap "Redundancy & Security Level" to set up Redundancy & Security level [Redundancy & Security Level Button] [Redundancy & Security Level set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 57 RPT-100 Date 2017-08-03 User Manual Page 4.2.5.5. Delimiter Tap “Delimiter” to be set Delimiter [Delimiter Button] [Delimiter set-up Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 58 RPT-100 Date 2017-08-03 User Manual Page 4.2.5.6. Factory Reset Initialize scanner settings of the Device. Tap "YES" button to proceed. [Factory Reset Button] [Factory Reset confirmation] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 59: Scan Tab

    RPT-100 Date 2017-08-03 User Manual Page 4.3. Scan Tab Tap “Scan” that read barcode and UHF Tag and display the scanned data. [Scan Tab] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 60: Rfid Button

    When tap to “Stop” button, It will be stopped to read UHF RFID Tag. [RFID Button] [Tag Reading] [Stop Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 61: Barcode Button

    Scanned barcode is updated on the list and it will show you number of rereading barcode and total reading number. Just tap “Stop” button to stop operation. [Barcode Button] [Barcode Reading] [Stop Button] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 62: Delete Button

    Page 4.3.3. Delete Button Tap "Delete" button and new window will appear to be confirmed “Delete”. If yes, it will be deleted the selected list [Delete Button] [Confirmation Delete] [Delete] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 63: App

    RPT-100 Date 2017-08-03 User Manual Page 4.4. App “App” is menu to search for UHF RFID Tag Memory Read / Write / Tag. [App Tab] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 64: Read Tag

    “Read Tag” is function to output data from reading memory of UHF RFID. It can be read EPC / TID / Password / User in the memory as specified format. [Read Tag Button] [Read Tag Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 65: Write Tag

    “Write Tag” is a function to write data in the memory of UHF RFID Tag Data can be written in the memory of EPC / PASSWORD / USER area according to the specified format. [Write Tag Button] [Write Tag Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 66: Single Search Tag

    Page 4.4.3. Single Search Tag Single Search Tag is a function to find the position of specified Tag while reducing TX Power. [Single Search Tag Button] [Single Search Tag Menu] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 67: Multi Search Tag

    4.4.4. Multi Search Tag “Multi Search Tag” is a function to search for tags in the list up to 50 tags registered. [Multi Search Button] [Tag Add / Delete] [Edit List] [Tag Search] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 68: Wildcard Search Tag

    RPT-100 Date 2017-08-03 User Manual Page 4.4.5. Wildcard Search Tag “Wildcard Search Tag” is function to use *,? To search for specified tags. [Multi Search Button] [Tag Add / Delete] CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 69: Pc Test Program

    This program (RFIC_CMD) provides easy and simple test of Command (RSP Interface) required for device operation and Key Emulator function to use device as wired HID. 5.2. User Interface information CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 70: How To Use

    ⑧ Explanation of the command selected in the RSP command list is displayed through the RSP command description window.. ⑨ Receive data window ⑥ Transmit / Receive data window can be cleared by the clear button. CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 71 When Multi Mode is selected, multiple tags are read while the RFID button is held down. When Single Mode is selected, only one tag is read. ⑫ Adjust the TX output of the RPT-100. The tag read distance is adjusted according to the TX output.
  • Page 72: Tagfocus And Fastid Tag Supported

    TID Memory Family Model Address 0x00 ~ 0x1F 0xE2801100 Monza 4 0xE280110C 0xE2801105 Monza 5 0xE2801130 0xE2801160 Monza 6 R6-P 0xE2801170 S6-C 0xE2801171 2K Dura 0xE2801140 Monza X 8K Dura 0xE2801150 CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 73: Firmware Update

    User Manual Page 7. Firmware Update RPT-100 F / W update supports Windows XP, Windows 7, Windows 8, Windows 10 OS (32bit / 64bi t support). The following two applications are required for F / W update. SambarStart: This tool is used to erase F / W data on RPT-100 equipment.
  • Page 74: F/W Writing

    Never turn off the RPT-100, or remove the USB or Magconn cable..  7.1.2. F/W Writing Connect the F / W removed RPT-100 UHF and PC via USB cable, then run the SAM-BA.exe .  Select COM Port which connected by RPT-100 and select your board item as at91sam7s512-ek, ...
  • Page 75 RPT-100 Date 2017-08-03 User Manual Page If the region is locked, the “Unlock region” pop-up window will appear as shown below. Click  Yes (Y) button CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 76 When F / W writing is completed, the lock region popup window will appear. Click the Yes (Y) or  No (N) button. Click the Yes button to lock the region, or No to un-lock the region. Remove the USB or Magconn cable from the RPT-100 device.  To reset the device, please restart the RPT-100 equipment.
  • Page 77: Certification

    RFID/USN : 917.3 MHz ~ 920.3 MHz Temperature -20 ~ +50 ℃ Power 3.7 V The wireless device may cause propagation interference, we are not responsible for life-saving related services CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 78: Dotd-100 How To Use

    9. DOTD-100 How to Use If your PC does not support Bluetooth, please connect DOTD-100 to your PC, you can transfer the data from RPT-100 to your PC by wireless. The DOTD-100 device contains barcode with recorded mac address 9.1. Flow chart Bluetooth 9.2.
  • Page 79: How To Disconnect

    “Disconnecting ... OK” message on the LCD screen. The LED of DOTD-100 changes from green to red.. 9.4. How to set Enter as termination character Only when the RPT-100 operating mode is on the local mode, option setting can be operated through reading barcode 9.4.1. F/W 5.1.0.6 or above By reading the following barcode, “Enter”...
  • Page 80: F/W 5.1.0.5 Or Less

    Enter value by setting Suffix 1 / Suffix 2 as follows. scanner termination character Enter setting  Set SCAN Suffix 1 Set SCAN Suffix 2 CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 81 RPT-100 Date 2017-08-03 User Manual Page <DATA><SUFFIX 1><SUFFIX 2> CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 82 RPT-100 Date 2017-08-03 User Manual Page RFID termination character Enter setting  Set RFID Suffix 1 Set RFID Suffix 2 CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.
  • Page 83 RPT-100 Date 2017-08-03 User Manual Page <DATA><SUFFIX 1><SUFFIX 2> CONFIDENTIAL Document Gen2Wave. All rights of reproduction and disclosure reserved.

Table of Contents