Compressor Specifications - U-Line U29RB00A User Manual & Service Manual

Ada series, 29r, 21" solid door refrigerator
Hide thumbs Also See for U29RB00A:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Compressor Specifications

!
DANGER
Electrocution can cause death or serious injury.
Burns from hot or cold surfaces can cause
serious injury. Take precautions when servicing
this unit.
Disconnect the power source.
Do not stand in standing water when working
around electrical appliances.
Make sure the surfaces you touch are not hot or
frozen.
Do not touch a bare circuit board unless you are
wearing an anti-static wrist strap that is
grounded to an electrical ground or grounded
water pipe.
Handle circuit boards carefully and avoid
touching components.
To measure the start winding resistance, measure across
the C and S pins.
To measure the run winding resistance, measure across
the C and R pins.
Also check S to R and you should get the sum of the run
and start windings.
To ensure the windings are not shorted, check the S and R
to ground.
OVERLOAD PROTECTOR
STARTING RELAY
RELAY COVER
Refrigerant
Voltage
Frequency
Run Cap
Start Winding
Run Winding
LRA
FLA
Starting Device
Overload
* All resistance readings are ±10%
u-line.com
C
S
R
CAPACITOR
ULIN_0368_A
EMU30HSC
R134a
115 VAC
60 Hz
12μF/180 VAC
70 Ohm at 77°F
8.4 Ohm at 77°F
5.5 A
1.0 A
8EA14C
4TM197NFBYY-53
Compressor Specifications 1