1.
Check that the plug is fully pushed into the socket and is switched on.
2.
Check with some other electrical device that the wall socket is "live". If it is not, contact a qualified electrician.
3.
Check the fuse in the plug. If you replace the fuse, refit with a 13Amp fuse.
4.
Check the humidistat control is turned clockwise.
5.
Check that the water container is not full.
Should none of the above remedies work, then disconnect from the mains. Contact the help line on 01388 664400. DO
NOT attempt to repair the unit or unscrew the outer casing.
If the appliance is fitted with a plug for which your socket is unsuitable, then it should be cut off and an appropriate
plug fitted.
This appliance complies with the suppression requirements of the EEC direction 82/199/EEC as embodied in
BS800:1988.
IMPORTANT:- The wires in this mains lead are coloured in accordance with the following code:-
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings
identifying the terminals in your own plug, proceed as follows:
The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the
letter E or by the Earth Symbol or coloured Green and Yellow. The wire which is coloured Blue must be connected to
the terminal in the plug which is marked with the letter N or coloured Black. The wire which is coloured Brown must be
connected to the terminal which is marked with the letter L or coloured Red.
You must dispose of the non rewireable plug once it has been removed from the flexible cord. It is dangerous to
attempt to insert the plug into any electrical socket elsewhere in the house. If the flexible cord becomes damaged it
must be replaced by an identical cord.
Only 13 Amp fuses that are ASTA approved to BS1362 should be used.
The fuse cover must be refitted after replacement of the fuse. In the event of the fuse cover being lost or damaged, the
plug must not be used until a replacement is obtained. Replacement fuse covers, which must be coloured BLACK, are
obtainable from electrical retailers.
IF YOUR DEHUMIDIFIER FAILS TO OPERATE
ELECTRICAL CONNECTION
Green & Yellow
Blue
Brown
CHANGING THE FUSE
WARNING – THIS APPLIANCE MUST BE EARTHED
TECHNICAL SPECIFICATIONS
Min Operating Temperature
Max Operating Temperature
Water Extraction (24hrs) 32° C / 90%RH
Max Power Consumption 32° C / 90%RH
Max Running Current
Earth
Neutral
Live
CD35
230V/50Hz/1 Phase
Height
550 mm
Width
345 mm
Depth
350 mm
Weight
26 kg
1 ° C
35 ° C
10 l
250 W
2 A
Fuse Rating (UK)
13 A