HAWE Hydraulik SE EV1D Assembly Instructions Manual

Electronic amplifier, modular construction, supply voltage ub 10...48 v dc, output current ia max. 2 a

Advertisement

Quick Links

Electronic amplifier type EV1D

Assembly instructions

Modular construction
Supply voltage U
:
10...48 V DC
B
Output current I
:
max. 2 A
A
© by HAWE Hydraulik SE.
The forwarding and reproduction of this document, as well as the use and communication of its contents, are forbidden unless expressely permitted.
Any breach or infringement will result in liability for damages.
All rights reserved concerning patent or utility model application.
B 7831 D
09-2015-1.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EV1D and is the answer not in the manual?

Questions and answers

Summary of Contents for HAWE Hydraulik SE EV1D

  • Page 1: Assembly Instructions

    Electronic amplifier type EV1D Assembly instructions Modular construction Supply voltage U 10...48 V DC Output current I max. 2 A © by HAWE Hydraulik SE. The forwarding and reproduction of this document, as well as the use and communication of its contents, are forbidden unless expressely permitted.
  • Page 2: General Parameters

    Supply lines, such as inputs and outputs to and from the device, should be as short as possible. If necessary they should be shielded ■ and twisted in pairs (to reduce the antennae-like effect for increasing the immunity to interference). © HAWE Hydraulik SE D 7831/D - EV1D - 09-2015-1.3...
  • Page 3: Printed Circuit Board

    0...5 V / 0...10 V target value input X2-4 0 V analogue (GND) X2-5, Auxiliary inputs, programming interface X2-6, Proportional amplier (card) EV1D + solenoid Jumper J1 + solenoid Auxiliary inputs, programming interface 10 V © HAWE Hydraulik SE D 7831/D - EV1D - 09-2015-1.3...
  • Page 4 Note Note that the parameter values can only be modied in discrete steps using the keypad. Conversion factors that match physical values to the respective increments are stated under "Standardisation". © HAWE Hydraulik SE D 7831/D - EV1D - 09-2015-1.3...
  • Page 5: Setting Instructions

    The amplifier switches back to normal operation. Normal operation Parameterisation mode Parameter Parameter Parameter modification storage selection Parameter no. Value increase Target value display increase Value reduction Parameter no. Error code display reduction Timeout 10 s © HAWE Hydraulik SE D 7831/D - EV1D - 09-2015-1.3...
  • Page 6 3. Push the printed circuit board (1) into the circumferential location slot (5) 4. Insert the remaining card holder side part (3) or (7) ✓ The module is now assembled in the card holder. © HAWE Hydraulik SE D 7831/D - EV1D - 09-2015-1.3...
  • Page 7: Typical Circuits

    Pay attention to the maximum load of the Not used power source. Enable/block F1 = as in example A Rx = 250 Ω/0.5 W Jumper J1 5 V DC Example E Jumper J1 10 V DC © HAWE Hydraulik SE D 7831/D - EV1D - 09-2015-1.3...
  • Page 8: Further Information

    Directional seated valve type EM and EMP: D 7490/1 ■ HAWE Hydraulik SE Streitfeldstraße 25 | 81673 München | Postfach 80 08 04 | 81608 München | Germany Tel +49 89 379100-1000 | Fax +49 89 379100-91000 | info@hawe.de | www.hawe.com...

Table of Contents