5. Check LCD Module
No Picture
No Picture
Lamp connector OK ?
YES
YES
Lamp wire
OK
?
NO
NO
LCD module fail
LCD module fail
To display
To display
image
image
NO
NO
Bad Connection
Bad Connection
or connector,
or connector,
YES
YES
Inverter board
failed
LCM failed
- 53 -
White Screen
White Screen
Connection between
LVDS cable and
LCM connector
OK ?
YES
YES
Connection between
LVDS cable and
LVDS connector
OK?
YES
YES
Is Q6 5V?
YES
YES
Bad Connection
Bad Connection
NO
NO
or connector,
or connector,
LVDS cable
LVDS cable
Bad Connection
Bad Connection
NO
NO
or connector,
or connector,
LVDS cable
LVDS cable
NO
NO
Check Q6
Check Q3