3. PARTS & CONTROLS
3.1 Description of Parts & Controls
1
5
2
6
10 8
9
9
4. Function selector :
For selection of desired function.
5. Range button :
A. In ACA, ACV, DCV, mA, Capacitance and
Resistance function.
1. Press it once to enter the manual range select
mode, LCD will show ® mark.
2. Press again to select the desired range.
3. Press it 2 seconds to exit the manual range and
enter to the autorange mode, LCD ® mark will be
disappered.
B. In KW/HP/KVA function
a. Press RANGE button to select viewing the
KW/hp, KW/PF, KW/KVAR, KVA/u or V/A dual
display.
B1.Press HOLD button keep the measured valued
in memory.
B2.Press RANGE button to select viewing the
KW/hp, KW/PF, KW/KVAR, KVA/u or V/A dual
display.
B3. Press HOLD button to exit this mode.
C. In TEMP function
1. Press RANGE button to select desired C or F
temperature units.
6. Temperature input jack :
Only type K thermocouple input is accepted.
7. LCD Display :
4 digital LCD with indications for measurement values,
unit symbols, decimal point, polarity, over range and
low battery; etc.
8. COM Jack :
Connect black test lead for voltage, Power,
Capacitance, Resistance, Diode, Countinuity and
Micro ampere measurement.
9. " V " Jack :
Connect red test lead for Voltage and Power
measurement as a positive terminal.z
11
Fig.
1
3
11
4
7
0
0
1. Transformer jaws (+mark to face source) :
To pick up the AC current flowing through the conductor.
2. Jaw opening trigger
3. Data Hold (MX/MN) button :
a. Data Hold Mode :
Press it once to hold the measured value and store the
value in memory. Press again to release hold function.
(except capacitance function)
b. Maximum and Minimum with Elapsed Time mode
1. Select desired ACA, ACV, DCV, C/ F or mA
function and perform the measurement, until the
measured value shows stable reading on the LCD.
2. Press " MX/MN " button for 2 seconds to enter
recording with Elapsed Time mode, LCD will show
" ® " mark to lock the measurement range and
" MX/MN " mark to indicate the current measured
value with current elapsed time. The Auto Power
Off function will be automatically cancelled.
3. Press " MX/MN " button one time, LCD will show
" MX " mark to indicate the recorded Maximum
value and maximum value occurred Elapsed Time.
4. Press " MX/MN " button one time, LCD will show
" MN " mark to indicate the recorded Minimum value
and minimum value occurred Elapsed Time.
5. Press " MX/MN " button one time, LCD will show
" MX/MN " mark to indicate the current value and
current Elapsed Time.
6. Step 3, 4, 5 can be cycled.
7. Press " MX/MN " button for 2 seconds to exit this
mode.
Note : The Elapsed Time intial setting is " minute :
second ", when current Elapsed Time is
over 60 minutes, the Elapsed Time will be
auto setting to " hour : minute ". The
maximum Elapsed Time length is 100
hours.
10. "
V
m A "Jack :
Connect red test lead for Capacitance, Resistance,
Diode, Countinuity and Micro ampere measurement
as a positive terminal.
11. 3 Phase Adapter :
Insert plug in type 3 phase adapter in terminals
" COM " and " V " for 3 phase 3 wire power measurement.
4. OPERATING INSTRUCTION
4.1 AC + DC Voltage Measurement
Maximum input is 600V. Do not attempt to take any
voltage measurement that exceeds these limits.
Exceeding these limits could cause electrical shock
and damage to the clamp meter.
1. Set the rotary switch to the " V " position.
2. Insert the test leads in to the input jack. (Black to COM
and Red to V)
3. Connect the test leads in PARALLEL to the measured
circuit.
4. The meter will automatically switch to ACV or DCV
display.
5. The meter will automatically select the appropriate range.
6. Read the voltage and frequency values displayed on
the LCD.
The sensitivity for voltage frequency measurement is 1.2V
and the frequency range is 40 - 1KHz. If the frequency is
less than 40Hz the LCD may show Hz.