RTS ADAM-M System Installation Manual

RTS ADAM-M System Installation Manual

Advanced digital audio matrix

Advertisement

ADAM - M
Advanced Digital Audio Matrix
System Installation Guide
Rev. 10
OCTOBER/2015
F.01U.216.986

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADAM-M and is the answer not in the manual?

Questions and answers

Summary of Contents for RTS ADAM-M

  • Page 1 ADAM - M Advanced Digital Audio Matrix System Installation Guide Rev. 10 OCTOBER/2015 F.01U.216.986...
  • Page 2 ADAM-M System Installation Guide ROPRIETARY OTICE The product information and design disclosed herein were origi- nated by and are the property of Bosch Security Systems, Inc. Bosch reserves all patent, proprietary design, manufacturing, repro- duction, use and sales rights thereto, and to any article disclosed therein, except to the extent rights are expressly granted to others.
  • Page 3: Important Safety Instructions

    ADAM-M System Installation Guide Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  • Page 4 ADAM-M System Installation Guide Bosch Security Systems, Inc. Rev. 10 F.01U.216.986 System Installation Guide...
  • Page 5: Table Of Contents

    Front Card Access ............................. 17 Card Removal and Installation .......................... 17 Unused Back Card Slots ............................ 19 Supported ADAM-M Configurations ........................ 19 Master Controller Card DIP Switches ....................... 20 Power Supply Removal and Installation ....................23 Fan Removal and Replacement ......................24 AC Power - Chassis ..........................25...
  • Page 6 ADAM-M System Installation Guide Connecting the Master Controller Breakout Panel .................... 39 Configuration Computer Connection and Check ....................39 Trunk Master ..............................40 General Description ............................40 Hardware Requirements ..........................40 Connecting the TM-2000/MTM-2000 ......................41 UIO-256/GPIO-16 Input/Output Frame ......................41 Connecting a single UIO-256/GPIO-16 Frame ....................
  • Page 7 Typical GPI output connection ..................33 FIGURE 9. Y-Cable Diagram ......................43 FIGURE 10. Interconnect Cable From ADAM-M ................46 FIGURE 11. Cable to interconnect two (2) LCPs.................. 46 FIGURE 12. Keypanel with Data Cabling ..................... 47 FIGURE 13. Audio Only Cabling ......................48 Bosch Security Systems, Inc.
  • Page 8 ADAM-M System Installation Guide F.01U.216.986 System Installation Guide Rev. 10 Bosch Security Systems, Inc.
  • Page 9: Introduction

    The ADAM-M, utilizing existing cables and bus expanders, integrates and expands existing intercom systems into larger systems with minimal effort. Hot Swappable Not only are the I/O cards in the ADAM-M hot-swappable, but the power supplies and fans are Components completely removable and hot swappable, making replacement and maintenance easier than ever.
  • Page 10: Reference View

    10 Introduction ADAM-M System Installation Guide Reference View ADAM-M Reference View FIGURE 1. Status LEDs Front Cover Thumb Screws Alarm Override Button Power Supplies DC Power On/Off Button DC Power On/Off Button Filter Module Power Test Point Banana Jacks Fan Module...
  • Page 11: Specifications

    Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids shall not be placed on • the apparatus (EN 60065 Clause 5.4.1a). The ADAM-M is to be connected to a mains socket outlet with a protective earth connection (EN 60065 Clause • 5.4.1d).
  • Page 12: Alarm Operation

    12 Introduction ADAM-M System Installation Guide Alarm Operation The ADAM-M is equipped with a power supply fault, fan fault, and over-temperature alarm. If there is a problem detected in any of these areas, an audible alarm sounds. Power issue If only one (1) power supply is running, an alarm sounds because redundant power is not active.
  • Page 13: Chassis

    Chassis Mounting the Central Matrix Components CAUTION: To avoid potentially dropping and damaging the ADAM-M, verify the thumbscrews are secure and be sure to grasp the front door and the main unit rack ears together when transporting the frame. ADAM-M—Proper Carrying Position FIGURE 2.
  • Page 14 Make sure the ventilation holes on the both sides are unobstructed (minimum 2”). The rack space behind the ADAM-M Card Frame should be kept completely clear to allow for connections and the insertion and removal of back cards (at least 2 feet).
  • Page 15: Initial Setup

    • To set up the ADAM-M, do the following Connect the power cord connector end(s) to the power module on the rear side of the ADAM-M. Connect the power cord plug(s) to an electrical outlet. Using an Ethernet cable, connect the Primary MCII-e (J1) to the computer hosting AZedit.
  • Page 16 16 Chassis ADAM-M System Installation Guide Verify the following Status LEDs are good (on): AC/DC Status • Power Status • Alarm Status • Fan Status • Using AZedit, verify ADAM is communicating with the computer. Bosch Security Systems, Inc. System Installation Guide F.01U.216.986...
  • Page 17: Adam-M Cards

    Card Removal and Installation All ADAM-M circuit cards can be hot-installed, which means you do not have to turn the power off before installing or removing a card. This permits continuous operation of the intercom system - with no interruptions to unaffected ports - in the event of a card failure.
  • Page 18 Orient the front card so the reset switch is on the left-hand side. Insert the card edges into the right and left card guides in the front of the ADAM-M frame. Push the front card into the slot until initial resistance is felt.
  • Page 19: Unused Back Card Slots

    Place MADI Card in slot 8 Place TBX Cards in slots 4, 5, and 6 When three (3) TBX cards are used in the ADAM-M, only one (1) MADI card can be used in the system. System Installation Guide Bosch Security Systems, Inc.
  • Page 20: Master Controller Card Dip Switches

    20 Chassis ADAM-M System Installation Guide Master Controller Card DIP Switches As shipped from the factory, all master controller card DIP switches are set to the default operation position. These settings are satisfactory for most applications. Optional settings are summarized in Table 3 on page 21 If any changes are made to the settings, make sure both the main and backup controller cards are set the same.
  • Page 21 ADAM-M System Installation Guide Chassis 21 MCII-e Version 1.6.2 Dip Switch Settings TABLE 3. Dip Switch Description Debug Only! Must be in open position. Sets the baud rate for the AZedit serial connection via J1. By default, AZedit is set for COM 1 and 38,400 kbps (38.4K).
  • Page 22 22 Chassis ADAM-M System Installation Guide MCII-e Version 1.19.2 Dip Switch Settings TABLE 5. Dip Switch Description Debug Only! Must be in open position. Sets the baud rate for the AZedit serial connection via J1. By default, AZedit is set for COM 1 and 38,400 kbps (38.4K).
  • Page 23: Power Supply Removal And Installation

    Lift up the finger lock holding the power supply in place. Rotating counterclockwise, rotate the finger lock half a turn. The finger lock stays in the open position. Pull the power supply out of the ADAM-M chassis. System Installation Guide Bosch Security Systems, Inc.
  • Page 24: Fan Removal And Replacement

    Remove the front door from the ADAM-M unit. Lift up the thumbscrew for power supply 2. Find the Fan Removal Tab. Using the fan removal tab, pull the fan unit from the ADAM-M chassis. Bosch Security Systems, Inc. System Installation Guide F.01U.216.986...
  • Page 25: Ac Power - Chassis

    AC Power - Chassis The ADAM-M Chassis has two (2) separate power sources; the power to the chassis and the power to the power supply. The power on/off buttons on the front of the unit power the chassis, while the AC power connectors on the rear of the unit power the power supply.
  • Page 26: Fuse Replacement

    To replace the fuse on the ADAM-M, do the following: Power off the ADAM-M unit. On the rear of the ADAM-M, locate the AC power connectors. (see Figure 1 on page 10.) Using a small screwdriver, pry open the AC power connector.
  • Page 27: Adam-M Frame Power-Up

    Press the power buttons on the front of the ADAM-M Frame to power the frame on. See Figure 1 on page 10. The LED indicators and all voltage indicators should light. The fans should turn on. The alarm should shut off.
  • Page 28: Circuit Card Reset And Fail Indication

    28 Chassis ADAM-M System Installation Guide Circuit Card Reset and Fail Indication Each front card is equipped with a reset button located near the top front of the card. Directly under the reset button is the red LED fail indicator (see Figure 5). The LED indicator remains off during normal operation. If the fail indicator turns on, first attempt to restore normal operation by momentarily pressing the reset button.
  • Page 29: Xcp-Adam-Mc

    CHAPTER 3 XCP-ADAM-MC Breakout Panel XCP-ADAM-MC (Gilman, Mike, illus. 2010) FIGURE 6. System Installation Guide F.01U.216.986 Bosch Security Systems, Inc. Rev. 10...
  • Page 30: Connector Pinouts

    30 XCP-ADAM-MC ADAM-M System Installation Guide Connector Pinouts General Purpose 68-pin J-4 of Assignment 2W AZedit #1 Master XCP-ADAM-MC Controller 68-pin J-1 of Assignment RS485 TX/RX- Master XCP-ADAM-MC Controller Ground RS485 TX/RX- Not Used RS232C RX Not Used RS232C TX...
  • Page 31 ADAM-M System Installation Guide XCP-ADAM-MC 31 General Purpose / Bus Exp. AZedit #3 68-pin J-7 of Assignment 2W 68-pin J-10 of Assignment 2W Master XCP-ADAM-MC Master XCP-ADAM-MC Controller Controller RS485 TX/RX- Not Used Ground Ground Not Used RS232C RX Not Used...
  • Page 32: Connections

    32 XCP-ADAM-MC ADAM-M System Installation Guide General Purpose Interface (GPI) Connector IMPORTANT: For complete pin out descriptions for the General Purpose ADAM Breakout Panel, which includes Assignment Signal the GPIO, see the Breakout Panel Resource Guide. The Breakout Panel Resource Guide can be found on the website,www.rtsintercoms.com.
  • Page 33 ADAM-M System Installation Guide XCP-ADAM-MC 33 Typical GPI output connection FIGURE 8. System Installation Guide Bosch Security Systems, Inc. F.01U.216.986 Rev. 10...
  • Page 34 34 XCP-ADAM-MC ADAM-M System Installation Guide Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10...
  • Page 35: Device Connections

    CHAPTER 4 Device Connections General Information Typically, devices are connected to individual intercom ports using Station Breakout Panels as shown in the in the drawings starting on page 35. Depending on the type of breakout panels being used, the individual intercom stations utilize either RJ-12 for keypanels, RJ-11 for audio only devices, or 9-pin D-sub cables.
  • Page 36: Logical Keypanel Numbers

    36 Device Connections ADAM-M System Installation Guide Logical Keypanel Numbers Even though separate data pins are provided for each intercom port, these pins do not actually represent a unique data port. Rather, groups of intercom ports share a common data port. In an ADAM intercom system, data groups consist of eight (8) intercom ports, and each Audio Input/Output card represents one (1) data group.
  • Page 37: General Procedure For Connecting Devices To The Intercom

    ADAM-M System Installation Guide Device Connections 37 General Procedure for Connecting Devices to the Intercom The following is a suggested method for planning the AIO card intercom system and connecting devices to intercom ports: Make a copy of the Intercom System Planning Worksheet Figure , “AIO Card System Planning •...
  • Page 38: Specifications

    38 Device Connections ADAM-M System Installation Guide Master Controller Breakout Panel – XCP-ADAM-MC The XCP-ADAM-MC Breakout Panel affords the ADAM more connections to frame accessories, see “XCP-ADAM-MC” on page 29, without losing the connection to AZedit, and the ability to trunk systems.
  • Page 39: Connecting The Master Controller Breakout Panel

    ADAM-M System Installation Guide Device Connections 39 Connecting the Master Controller Breakout Panel To connect the XCP-ADAM-MC to the ADAM-M, do the following: Connect J12 on the back of the XCP-ADAM-MC to J2 on the MCII-e back card. > OR...
  • Page 40: Trunk Master

    (2) or more frames are interconnected to form one (1) larger system. The RTS Trunking System consists of a TM-2000 or MTM-2000 and one(1) or more ICP-2000 Interconnect Panels, depending on the number of intercom systems to be trunked. A backup TM-2000 or MTM-2000 may also be added to prevent downtime in the event of a failure of the main master control unit.
  • Page 41: Connecting The Tm-2000/Mtm-2000

    For more detailed installation and configuration instructions, see the TM-2000/MTM-2000/SWP-2000/ICP-2000 user manual (P/N 9350 7715-000). Connecting the TM-2000/MTM-2000 To connect the TM-2000 to the ADAM-M frame, do the following: Connect the J2 trunk data port of the XCP_ADAM-MC to the respective port on the ICP-2000. >...
  • Page 42: Connecting A Single Uio-256/Gpio-16 Frame

    42 Device Connections ADAM-M System Installation Guide UIO-256 user manual (P/N 9330-7499-000) • OR GPIO-16 user manual (P/N 9350-7842-000) NOTE: The baud rate, as well as all UIO-256/GPIO-16, PAP, and LCP-102 devices is fixed at 76.8k baud. Connecting a single UIO-256/GPIO-16 Frame To connect a single UIO-256/GPIO-16 frame, do the following: Using a RS-485 data cable, connect a single UIO-256/GPIO-16 to J3 of the Master Controller Breakout Panel.
  • Page 43 ADAM-M System Installation Guide Device Connections 43 Connect to the opto-isolator outputs and relay inputs as for the first UIO-256/GPIO-16. Y-Cable Diagram FIGURE 9. System Installation Guide Bosch Security Systems, Inc. F.01U.216.986 Rev. 10...
  • Page 44: Pap-32

    44 Device Connections ADAM-M System Installation Guide PAP-32 General Description Up to 15 PAPs (Program Assign Panel) can be connected to the intercom system. Each PAP has DIP switches to assign it as panel number 1 through 15, and to select either a low or high IFB range. As supplied, PAPs expect all program sources to be connected to sequential intercom ports of the intercom system starting with port #1.
  • Page 45: Lcp-102

    The LCP-102 connects to the auxiliary data port of any ADAM, ADAM-M, Cronus, or Zeus intercom system. Also, it has a loop connector for connection to an auxiliary device, such as another LCP-102, or a UIO-256/GPIO-16 frame. Since a single LCP-102 provides trim adjustments for 64 ports, only one (1) unit is required to completely configure an ADAM-M or Zeus system.
  • Page 46 When connecting keypanels and audio/data devices to a frame, a breakout panel must be used. A breakout panel allows you to connect multiple devices with the same connection type to one (1) AIO card. Available breakout panels for the ADAM-M frame are: XCP-954-48 XCP-32-DB9 •...
  • Page 47 Audio only devices, such as SSA-324, DSI-2008, etc. must use a breakout panel. A breakout panel allows you to connect multiple devices with the same connection type to one (1) AIO card. Available breakout panels for the ADAM-M frame are: XCP-954-48 XCP-32-DB9 •...
  • Page 48 48 Device Connections ADAM-M System Installation Guide For specific information on your keypanel or audio device, consult the devices user manual: Audio Only Cabling FIGURE 13. Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10...
  • Page 49 ADAM-M System Installation Guide Device Connections 49 AIO Card System Planning Worksheet Intercom ADAM Logical AZedit AZedit Description Port No. Audio I/O Keypanel Alpha Alias (Device Type, Location, User, etc.) Card No. Number System Installation Guide Bosch Security Systems, Inc.
  • Page 50 50 Device Connections ADAM-M System Installation Guide Intercom ADAM Logical AZedit AZedit Description Port No. Audio I/O Keypanel Alpha Alias (Device Type, Location, User, etc.) Card No. Number 1-10 1-10 1-10 1-10 1-10 Bosch Security Systems, Inc. System Installation Guide F.01U.216.986...
  • Page 51 ADAM-M System Installation Guide Device Connections 51 Intercom ADAM Logical AZedit AZedit Description Port No. Audio I/O Keypanel Alpha Alias (Device Type, Location, User, etc.) Card No. Number 1-10 1-10 1-10 1-11 1-11 1-11 1-11 1-11 1-11 1-11 1-11 1-12...
  • Page 52 52 Device Connections ADAM-M System Installation Guide Intercom ADAM Logical AZedit AZedit Description Port No. Audio I/O Keypanel Alpha Alias (Device Type, Location, User, etc.) Card No. Number 1-15 1-15 1-15 1-15 1-16 1-16 1-16 1-16 1-16 1-16 1-16 1-16...
  • Page 53 ADAM-M System Installation Guide Device Connections 53 Intercom ADAM Logical AZedit AZedit Description Port No. Audio I/O Keypanel Alpha Alias (Device Type, Location, User, etc.) Card No. Number System Installation Guide Bosch Security Systems, Inc. F.01U.216.986 Rev. 10...
  • Page 54 54 Device Connections ADAM-M System Installation Guide Intercom ADAM Logical AZedit AZedit Description Port No. Audio I/O Keypanel Alpha Alias (Device Type, Location, User, etc.) Card No. Number 2-10 2-10 2-10 2-10 2-10 2-10 2-10 2-10 2-11 2-11 2-11 2-11...
  • Page 55 ADAM-M System Installation Guide Device Connections 55 Intercom ADAM Logical AZedit AZedit Description Port No. Audio I/O Keypanel Alpha Alias (Device Type, Location, User, etc.) Card No. Number 2-13 2-13 2-13 2-13 2-13 2-13 2-13 2-14 2-14 2-14 2-14 2-14...
  • Page 56 56 Device Connections ADAM-M System Installation Guide Bosch Security Systems, Inc. System Installation Guide F.01U.216.986 Rev. 10...
  • Page 57: Rj-45 Backcard

    1-6. To install the RJ-45 back card into an existing ADAM-M frame, do the following: NOTE: The following instructions can be used for installing an RJ-45 backcard in a new ADAM-M system with blank card plates.
  • Page 58 ADAM-M System Installation Guide Using a Phillips head screwdriver, remove the two (2) screws of the adjoining extended card plate on the rear of the chassis. Using a long shaft Phillips head screwdriver, remove the collared screw inside the chassis.
  • Page 59 Replace the AIO-16 front card you initially removed, taking care to properly seat it in the slot. To remove the RJ-45 backcard from the ADAM-M, do the following: Using your fingers or a flat-head screwdriver, loosen the two (2) thumbscrews from the ADAM M chassis, being careful not to remove the screws from the RJ-45 backcard.
  • Page 60 ADAM-M System Installation Guide RJ-45 Connector Pin Out Pin 1 Data + Pin 2 Data- Pin 3 Audio Out + Pin 4 Audio In + Pin 5 Audio In - Pin 6 Audio Out - Pin 7 Data + Pin 8 Data - ...
  • Page 61: Notes

    ADAM-M System Installation Guide Notes System Installation Guide Bosch Security Systems, Inc. F.01U.216.986 Rev. 10...
  • Page 62 Bosch Security Systems, Inc. 12000 Portland Avenue South Burnsville, MN 55337 U.S.A. www.boschcommunications.com...

Table of Contents