D. Control of water pressure in the installation
Pay attention to the value of water
pressure during operation of the water
softener. If the pressure of feed water
drops below 1.4 bar, determine the
cause of the drop and remove it. If the
pressure of feed water exceeds 8.0
bars, install relevant pressure
regulator (reducer) in the water feed
system.
E. Mechanical filter operation
In order to secure proper operation of
the water softener, the mechanical
filter, supplied together with the
device, must be installed on the raw
water pipework (see figure no. 1).
The mechanical filter is designed to
protect the control head as well as
the medium against mechanical
impurities (contamination).
Observation of contamination
condition of the filter screen (water
cleaning medium) is carried out by
visual inspection. An additional
element enabling control of the filter
condition is monitoring of water
pressure upstream and downstream
of the filter. In case of a filter with
replaceable screen, if the screen is
used (contaminated), unscrew the
filter sump holding the screen,
replace it with a new filter screen and
tighten the sump with the new filter
screen back to the filter assembly.
Bear in mind to cut off water
F. Control of current hour clock indications

2. Automatic disinfection of the medium featured by Aquahome 30-N

As a standard, Aquahome 30-N is
fitted with a special medium
disinfection system that combines a
probe with electrodes, cabling and
an additional micro switch. This
system is installed on the brine line
and is automatically activated during
the regeneration process. During the
course of one of the regeneration
Control of the time indications shown on the display screen of the
water softener should be performed at least once every fortnight. It
will prevent any movements in time of commencing the
regeneration process. To eliminate any possible difference
between current time and the time displayed by the device, follow
the guidelines provided on page 9 (for Aquahome 20-N) or on page
12 (for Aquahome 30-N).
26
Please bear in mind that the control
system (including the conditions of
the REGENERATION process, which
is carried out automatically) was set
for water pressure value in the range
between 1.4 bar to 8.0 bars.
Try to avoid water pressure hammers
during operation of the device.
upstream of the filter before carrying
out the filter screen replacement.
Important notice!
The filter screen must not be rinsed,
cleaned or reclaimed (regenerated)
in any other manner.
In case of a filter with a backwash
feature, follow the instruction
provided together with the filter.
Operating of a filter with an overused
filter screen may undermine water
quality and may cause damage to the
water softener.
stages - the brining, an electrolysis
occurs in the flowing salt solution
that generates a small quantity of
free chlorine on one of the
electrodes and chlorine generated
this way is used as a disinfection
agent. Then the salt brine with a
small quantity of chlorine is directed
to the resin tank. The salt brine is

Hide quick links: