Fault Finding Tests 10 & 12-14
Test 13
1
3
S
2
1
2
T
1
1
U
3
2
V
1
Conduct test with flame present.
Using a multimeter set on the AC volts scale,
measure the voltage between W1 at terminal U
and earth.
Normal voltage should be 1 - 100VAC.
TM061 Rheem 27 Water Star Service Instructions – Issued: 11/10
REV A Issued 08/13
This document is stored and maintained electronically by
Tests 10 and 12
BK R
BR
Y
G W
SW1
SW2
1 2 3 4 5 6
7
8
K
7
BL
6
W
5
Y
N
4
R
O
9
BK
4
8
BK
2
BK
3
7
6
R
R
2
6
G
5
P
1
5
4
Y
4
BL
3
3
O
2
2
1
W
1
BR
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled"
Test 10: Conduct test with water flowing.
Using a multimeter set on the DC volts scale,
measure the voltage between 1 Red and 2 Black at
terminal P whilst plugged into PCB.
Normal voltage is between DC1.5 and 14.0V.
Test 12: Isolate power before conducting test.
Using a multimeter set on the ohms scale,
measure the resistance between 1 Red and 2
Black at terminal P whilst unplugged from the PCB.
Normal resistance is between 40 ohms and 80
ohms.
Test 14
1
3
S
2
1
2
T
1
U
1
3
V
2
1
Unplug multi-pin connector from terminal T on
control PCB and using a multimeter set on the
kilo-ohms scale, measure the resistance of the
Over Heat Limiter assembly.
Normal resistance should be between 50 - 500
kilo-ohms.