Advertisement

Quick Links

User's manual VER-15
2016-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VER-15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Verano VER-15

  • Page 1 User’s manual VER-15 2016-01...
  • Page 2 User’s manual...
  • Page 3: Table Of Contents

    VER-15 Table of contents Safety ........................4 Description of the device ..................5 III. Installation ......................5 III.a) Connection diagram ..................... 6 First start-up ......................7 How to use the controller ................... 7 V.a) Principle of operation ..................... 7 V.b) Operation modes ....................7 V.b) Main screen view and description ................
  • Page 4: Safety

    User’s manual Safety Before using the device for the first time the user should read the following regulations carefully. Not obeying the rules included in this manual may lead to personal injuries or controller damage. The user’s manual should be stored in a safe place for further reference. In order to avoid accidents and errors it should be ensured that every person using the device has familiarized themselves with the principle of operation as well as security functions of the controller.
  • Page 5: Description Of The Device

    VER-15 Description of the device VER-15 room regulator is intended for controlling the heating or cooling device (e.g. gas, oil or electric furnace or the CH boiler controller). Its main task is to maintain the pre-set temperature in the flat by sending a signal to the heating/cooling device (contact opening) when the desired temperature is reached.
  • Page 6: Iii.a) Connection Diagram

    User’s manual VER-15 controller may be installed as a panel mountable on the wall. III.a) Connection diagram Room regulator should be connected with actuator with two-wired cable. Connection of both devices is shown on a diagram below: ATTENTION: Marking on the back of the controller refers to bulit-in relay.
  • Page 7: First Start-Up

    1. Remove the front cover of the controller and insert the batteries. 2. In the case of VER-15 connect the two-core cable to appropriate sockets in the receiver. How to use the controller V.a) Principle of operation VER-15 room regulator is designed to maintain desired room temperature by sending signal to actuator (contact closure) with information about necessity of heating.
  • Page 8 User’s manual  Day/night mode In this mode the pre-set temperature value depends on the current time of the day. The user may set different temperature values for the daytime and nighttime (comfort temperature and economical temperature) as well as define the exact time of entering day mode and night mode. In order to activate this mode, press EXIT button until day/night mode icon appears on the main screen.
  • Page 9 VER-15  Manual mode In this mode the pre-set temperature is adjusted manually from the main screen view with the use of these buttons: . Manual mode is activated when one of these buttons is pressed. When the manual mode is activated, the previous operation mode enters ‘sleep mode’ until the next pre-programmed temperature change.
  • Page 10: V.b) Main Screen View And Description

    User’s manual V.b) Main screen view and description The user operates the device using buttons. While one parameter is being edited, the remaining icons are not displayed. 1. Display 2. EXIT - pressing this button in the main screen view activates weekly control mode or day/night mode.
  • Page 11 VER-15 1. Current operation mode: a. weekly b. manual c. day/night 2. Current temperature of the room 3. Parameters icons (see: table below) 4. Icon indicating economical temperature (according to weekly control or day/night settings) 5. Icon indicating comfort temperature (according to weekly control or day/night settings) 6.
  • Page 12: V.c) Controller Functions

    User’s manual Parameters icons: Time settings Weekly control settings Day from… Comfort temperature Night from… Economical temperature Optimum start / heating- cooling mode selection (in Hysteresis service menu) Enter service menu / zone Temperature sensor calibration selection (EU-292v4) Channel selection V.c) Controller functions The user navigates the menu structure using , EXIT and MENU.
  • Page 13: V.c.2) Day Of The Week

    VER-15 V.c.2) Day of the week After entering the main menu, all icons which are not connected with the parameter which is being edited are not displayed. The first parameter is day of the week. Press until the current day of the week is displayed.
  • Page 14: V.c.6) Optimum Start

    User’s manual V.c.6) Optimum start Optimum start is an intelligent system controlling the heating/cooling process. It involves constant monitoring of the heating/cooling system efficiency and using the information to activate the heating/cooling process in advance in order to reach the pre-set temperatures. The system requires no user intervention.
  • Page 15: V.c.8) Weekly Control

    VER-15 Heating/cooling mode This function enables the user to select the room regulator operation mode: - controlling the cooling system - controlling the heating system Press to select desired type of system. Press MENU to confirm and move on to edit another parameter in the service menu or press EXIT to confirm to return to the main screen view.
  • Page 16 User’s manual Weekly program number Step 2 – select days of the week If the user wants to edit programs 1÷3, there is no possibility of selecting particular days of the week as the setting applies to each day. If the user wants to edit programs 4÷6 , it is possible to edit the settings for weekdays and the weekend separately.
  • Page 17: V.c.9) Pre-Set Comfort Temperature

    VER-15 The parameters of the weekly program are displayed at the bottom of the screen: hours to which comfort temperature has been assigned are displayed whereas hours to which economical temperature has been assigned are not displayed. Example: The following screenshot presents daily settings of program no.
  • Page 18: Vii.c.16) Temperature Sensor Calibration

    User’s manual Example: Pre-set temperature: 23°C Hysteresis: 1°C The room regulator reports that the temperature is too low only when the room temperature drops to 22 °C. In order to set the hysteresis, press MENU until the hysteresis setting appears on the screen. to set the desired hysteresis value.
  • Page 19 VER-15...
  • Page 20 User’s manual...

Table of Contents