ACD 300 Instruction Manual

Gas generator

Advertisement

Revision - 042898
MODEL 300
INSTRUCTION MANUAL
THIS INSTRUMENT GENERATES:
Bromine (Br
)
2
Chlorine (Cl
)
2
Chlorine Dioxide (ClO
)
2
Hydrogen Cyanide (HCN)
Hydrogen Sulfide (H
S)
2
Hydrogen (H
)
2
FACTORY-SET POINT:
_______ PPM
Air Flow _________

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 300 and is the answer not in the manual?

Questions and answers

Summary of Contents for ACD 300

  • Page 1 MODEL 300 INSTRUCTION MANUAL THIS INSTRUMENT GENERATES: Bromine (Br Chlorine (Cl Chlorine Dioxide (ClO Hydrogen Cyanide (HCN) Hydrogen Sulfide (H Hydrogen (H FACTORY-SET POINT: _______ PPM Air Flow _________ Revision - 042898...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS General Description Page 2 Start-Up Page 4 III. Altitude Adjustment Description Page 5 [ Blank Page ] Air Mode Page 6 How to Generate Gas Page 7 Cell Usage Page 8 VII. How to change Altitude Setting Page 9 VIII.
  • Page 3 Emmissions Standard (Residential Commercial and Light Industry) charges apply depending on the type of repair needed. EN 50082-1 Prices effective 01/01/98. ACD reserves the right to change pricing without notice. Please contact the factory for current pricing. Immunity Standard (Residential Commercial and Light Industry) Two exceptions to this compatibility are: The unit should not be operated with the charger attached.
  • Page 4: General Description

    Any parts found defective within that period battery life and avoiding generation of unwanted gas. The Model 300 uses the will be repaired or replaced, at our option, free of charge, F.O.B. factory. This...
  • Page 5 Strap 730-0350-00 Hard-body, Water Proof, Padded Carrying Case The model 300 comes equipped with a 1 1/2 inch wide nylon shoulder strap. 910-0300-00 Instruction Manual, generic The strap is mounted on the instrument so as to minimize roll over of the instrument.
  • Page 6: Start-Up

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 higher rate than the Model 300 pump. the generator will attempt to compen- 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 ACD.
  • Page 7: Altitude Adjustment Description

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 density, thus affecting the output. The Model 300 allows you to specify the 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 "SELECT"...
  • Page 8: Air Mode

    LPM) and 6-8 hours for high flow units (1 LPM to 2 LPM). To charge the At start-up, the instrument will battery simply plug in the AC adaptor. The Model 300 LCD should display display the current altitude 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 "Charging"...
  • Page 9: How To Generate Gas

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 A digital counter keeps track mode, the model 300 will run Generating Cl2...

Table of Contents